• Title/Summary/Keyword: comparison reference

Search Result 1,506, Processing Time 0.028 seconds

Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module (PV모듈 발전성능 비교시험과 계측편차 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

Analysis and measurement of service area of ocean-based DGPS reference station in Korea (국내 해상 DGPS 기준국의 서비스 영역 측정 및 분석)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1255-1261
    • /
    • 2014
  • Based on the radio wave measurement of korean ocean-based DGPS by season, in this paper, the service coverages of ocean-based DGPS reference stations were analyzed according to the climate and season. The signal strengths and signal-to-noise ratios in the land service areas that are provided by ocean-based DGPS reference stations were measured. The ocean-based DGPS reference station except reference stations on the mountainous terrain and the low ground conductivity provide more than 68% service area in comparison with the designed land service coverage providing by the ocean-based DGPS reference stations. To provide the designed service area that is unrelated to a season, it is necessary to install and operate the DGPS reference station with good ground conductivity and high efficiency antenna. Also, the poor service regions which is generated by obstacles of electric wave on pathway can be resolved by the double service area providing by land-based DGPS reference stations.

The Concentration of Serum Lipids and Protein Electrophoresis Fractions in Thyroid Disease Patients

  • Kim, Chong-Ho;Park, Seung-Taeck;Park, Seok-Tae;Kim, Jong-Ho;Kang, Young-Tae
    • Biomedical Science Letters
    • /
    • v.16 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • We analyzed and compared the concentration of total cholesterol (CHOL), high density lipoprotein (HDL) cholesterol, low density lipoprotein (LDL) cholesterol and triglyceride (TG) in serum and the serum protein electrophoresis fractions of thyroid disease patients. In comparison with the average of reference, our data showed that the average concentration of CHOL, LDL cholesterol and TG in hyperthyroidism patients were decreased significantly, but HDL cholesterol was increased significantly. In hypothyroidism patients, CHOL, HDL cholesterol, LDL cholesterol and TG were all increased significantly. In comparison of the concentration of lipids in each patient to reference range, 28.3% of hyperthyroidism patients showed abnormally low level of total cholesterol. In the patients with hypothyroidism, the percentage of patients showed abnormally high level of CHOL, HDL cholesterol, LDL cholesterol and TG were 37.7%, 10%, 68.8% and 49.1%, respectively. In our studies of serum protein electrophoresis, the average of ${\alpha}_2$-globulin and $\gamma$-globulin in hyperthyroidism patients were increased and $\beta$-globulin was decreased significantly. In hypothyroidism patients, the average of $\gamma$-globulin was increased and $\beta$-globulin was decreased significantly. In comparison of protein fractions of each patient to reference range, 38.3% and 50.0% of hyperthyroidism patients showed abnormally high levels of ${\alpha}_2$-globulin and $\gamma$-globulin, but 73.3% of patients showed abnormally low level of $\beta$-globulin. In hypothyroidism patients, 70.4% of patients were abnormally decreased in $\beta$-globulin and 63.9% of patients were abnormally increased in $\gamma$-globulin. These data suggest that the concentrations of CHOL, HDL cholesterol, LDL cholesterol and TG are not critical data for clinical interpretation of hyperthyroidism, but the levels of them are useful for interpretation of hypothyroidism patients. Our results of serum protein electrophoresis suggest that the concentration of serum protein electrophoresis fractions can be useful to understand the thyroid disease.

Preparation of wastewater-based reference materials for heavy metal analysis and interlaboratory study (중금속분석용 폐수표준물질 제조 및 실험실간 비교평가)

  • Kim, Young-Hee;Song, Ki-Bong;Shin, Sun-Kyoung;Lee, Jung-Sub;Jeong, Gi-Taeg;Hong, Eun-Jin;Park, Jin-Ju;Yu, Suk-Min
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2010
  • In this study, the wastewater-based reference material (RM) was prepared and certified for 7 trace metal elements with evaluation of uncertainties. The RM was distributed to 25 laboratories for the interlaboratory comparison testing. The certified values and expanded uncertainties were derived using ISO guideline 35 and the standard uncertainties for homogenieties were 0.43~2.67% of certified values. The analytical results from the interlaboratory comparison testing showed normal distributions and the robust means from the interlaboratory comparison testing were higher than the certified values of the RM for all analytes.

Comparison of the copy-neutral loss of heterozygosity identified from whole-exome sequencing data using three different tools

  • Lee, Gang-Taik;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.20 no.1
    • /
    • pp.4.1-4.8
    • /
    • 2022
  • Loss of heterozygosity (LOH) is a genomic aberration. In some cases, LOH can be generated without changing the copy number, which is called copy-neutral LOH (CN-LOH). CN-LOH frequently occurs in various human diseases, including cancer. However, the biological and clinical implications of CN-LOH for human diseases have not been well studied. In this study, we compared the performance of CN-LOH determination using three commonly used tools. For an objective comparison, we analyzed CN-LOH profiles from single-nucleotide polymorphism array data from 10 colon adenocarcinoma patients, which were used as the reference for comparison with the CN-LOHs obtained through whole-exome sequencing (WES) data of the same patients using three different analysis tools (FACETS, Nexus, and Sequenza). The majority of the CN-LOHs identified from the WES data were consistent with the reference data. However, some of the CN-LOHs identified from the WES data were not consistent between the three tools, and the consistency with the reference CN-LOH profile was also different. The Jaccard index of the CN-LOHs using FACETS (0.84 ± 0.29; mean value, 0.73) was significantly higher than that of Nexus (0.55 ± 0.29; mean value, 0.50; p = 0.02) or Sequenza (0 ± 0.41; mean value, 0.34; p = 0.04). FACETS showed the highest area under the curve value. Taken together, of the three CN-LOH analysis tools, FACETS showed the best performance in identifying CN-LOHs from The Cancer Genome Atlas colon adenocarcinoma WES data. Our results will be helpful in exploring the biological or clinical implications of CN-LOH for human diseases.

Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP (몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가)

  • Kang, Sung-Il;Kim, Ji-Yeon;Kim, Suk Mi;Lee, Jin Ju;Sung, So-Ra;Kim, Yeon-Hee;Jung, Suk Chan;Her, Moon
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Accuracy of genotype imputation based on reference population size and marker density in Hanwoo cattle

  • Lee, DooHo;Kim, Yeongkuk;Chung, Yoonji;Lee, Dongjae;Seo, Dongwon;Choi, Tae Jeong;Lim, Dajeong;Yoon, Duhak;Lee, Seung Hwan
    • Journal of Animal Science and Technology
    • /
    • v.63 no.6
    • /
    • pp.1232-1246
    • /
    • 2021
  • Recently, the cattle genome sequence has been completed, followed by developing a commercial single nucleotide polymorphism (SNP) chip panel in the animal genome industry. In order to increase statistical power for detecting quantitative trait locus (QTL), a number of animals should be genotyped. However, a high-density chip for many animals would be increasing the genotyping cost. Therefore, statistical inference of genotype imputation (low-density chip to high-density) will be useful in the animal industry. The purpose of this study is to investigate the effect of the reference population size and marker density on the imputation accuracy and to suggest the appropriate number of reference population sets for the imputation in Hanwoo cattle. A total of 3,821 Hanwoo cattle were divided into reference and validation populations. The reference sets consisted of 50k (38,916) marker data and different population sizes (500, 1,000, 1,500, 2,000, and 3,600). The validation sets consisted of four validation sets (Total 889) and the different marker density (5k [5,000], 10k [10,000], and 15k [15,000]). The accuracy of imputation was calculated by direct comparison of the true genotype and the imputed genotype. In conclusion, when the lowest marker density (5k) was used in the validation set, according to the reference population size, the imputation accuracy was 0.793 to 0.929. On the other hand, when the highest marker density (15k), according to the reference population size, the imputation accuracy was 0.904 to 0.967. Moreover, the reference population size should be more than 1,000 to obtain at least 88% imputation accuracy in Hanwoo cattle.

Tree image comparison analysis using LBP method (LBP 방식을 이용한 나무 영상 비교 분석)

  • Kim, Ji-hong;Lee, Jonghyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.4
    • /
    • pp.530-536
    • /
    • 2021
  • Since the LBP algorithm has the characteristic of local texture expression, it is possible to obtain completely different results depending on the extraction location and the size of the reference image and the sample image. In order to solve these shortcomings, in this paper, we first investigate the basic characteristics of LBP, make the size of the reference image (100×100) in order to include most of the characteristics in the image, and select a sample image (40×40) extracted from an arbitrary point. After finding the matching position in the LBP of the reference image by using the correlation test between the LBP of the reference image and the LBP of the sample image, a chi analysis method is used to find the reference image that most closely matches the sample image.

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.

On Reliability and Comparison of $J_{Rice}$-Resistance considering Optimal Strength Ratio and $J_{\delta}$-Resistance Curves converted from CTOD using Appropriate Strength chosen according to Strain Hardening Level (강도비를 적용한 Rice-저항곡선과 변형경화를 고려한 $J_{\delta}$-저항곡선과의 비교)

  • 장석기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2002
  • The comparison of $J_{Rice}$-resistance considering a few strength ratio in Rice J-integral formula and $J_{\delta}$-resistance curves converted from experimental CTOD using appropriate strength chosen according to strain hardening level, n=10.6 (A533B steel) and n=8.1 (BS4360 steel) is carried out. The optimal dimensionless strength ratio like the factor of revision, (see full text)reflecting strain hardening level in Rice\`s experimental formula is found out and the reliability of appropriate reference strength chosen according to strain hardening level in different materials is investigated through doing that CTOD is transformed from $J_{\delta}$-integral using relationship between J-integral and CTOD. The results are as follows; 1) The optimal factor of revision is when m equals to 3 in (see full text) for Rice's and the above optimal factor of revision multiplies by coefficient, η in Rice's experimental formula instead of n=2, 2) and the pertinent reference strength for high strain hardening material like BS4360 steel is ultimate strength, $\sigma_{u}$ and for material like A533B steel is ultimate-flow strength, $\sigma_{u-f}$. The incompatible of the behavior of both experimental J-resistance curves using Rice's formula and CTOD-resistance curves for A533B and BS4360 steel by Gordon, et al., could be corrected using the optimal factor of revision in Rice\`s and the pertinent reference strength in J=$m_{j}$${\times}$$\sigma_{i}$${\times}$CTOD.