• Title/Summary/Keyword: comparison of results

Search Result 27,077, Processing Time 0.064 seconds

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

Development of Composite Flours and Their Products Utilizing Domestic Raw Materials - I. Physical and Chemical Properties and Nutritional Test of Composite Flour Materials - (국산원료(國産原料)를 활용(活用)한 복합분(複合粉) 및 제품개발(製品開發)에 관한 연구(硏究) - 제 1 보 원료분(原料粉)의 이화학적성상(理化學的性狀) 및 영양시험(營養試驗) -)

  • Kim, Hyong-Soo;Lee, Kwan-Young;Kim, Sung-Kih;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.6-15
    • /
    • 1973
  • In an attempt to develop composite flours based on raw materials available in Korea, six domestic resources were investigated with respect to their physical and chemical properties, nutritive value and economy. The results are summarized as follows: 1) Flours from naked barley, sweet potato, potato, corn, defatted rice bran and defatted soybean were compared in respect of their proximate composition, thiamine content and protein score. 2) In color comparison, naked barley and defatted soy flours were comparable to wheat flour whereas corn and sweet potato flours were a little inferior. In raising power, naked barley and defatted soy flours were similar to wheat flour and others were inferior. 3) In maximum viscosity of flours by amylograph, naked barley, corn and potato flours were higher than wheat flour and others were lower. In viscosity in cooling, corn flour was similar to wheat flour and naked barley and potato flours were lower. Addition of $10{\sim}20%$ defatted soy flour into other flours generally caused the lowering of viscosity. Addition of emulsifiers such as glyceryl monostearate, calcium stearyl lactylate, Methocel and Emulthin into the flours manifested different effects on the amylogram. 4) In nutritional test by rat, diets consisting of naked barley, sweet potato, potato or corn flours, each containing defatted soy flour (at 10% level with exception of 20% for sweet potato flour) and naked barley flour fortified with lysine were similar to wheat flour in digestibility, but were superior in NPU and biological value. 5) In price estimation, sweet potato and corn flours were competitive with wheat flour, but naked barley flour was a little expensive. On the other hand, barley and sweet potato are promising in terms of domestic production.

  • PDF

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

The Comparison of Clinical Outcomes of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in High Risk Patients (고위험군 환자에서 시행한 On-Pump CABG와 Off-Pump CABG의 비교연구)

  • 윤영남;이교준;김치영;안지영;오영준;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.749-754
    • /
    • 2004
  • Off-pump coronary artery bypass grafting (Off-Pump CABG) has been proven to have less morbidity and to facilitate early recovery. High-risk surgical patients may have benefitted by avoiding the adverse effects of the cardiopulmonary bypass. We compared the effectiveness of Off-Pump CABG with that of coronary artery bypass using cardiopulmonary bypass (On-Pump CABG) in high-risk patients. Material and Method: 682 patients (424 Off-Pump CABG and 258 On-Pump CABG) underwent isolated coronary artery bypass grafting between January 2001 and June 2003. Patients who were considered high risk were selected High risk is defined as the presence of one or more of nine adverse prognostic factors. Data were collected from 492 patients in Off-Pump CABG and 100 in On-Pump CABG for risk factors, extent of coronary disease, and in-hospital outcomes. Result: Off-Pump CABG group and On-Pump CABG group did not show differences in their preoperative risk factors. We used more arterial grafts in Off-Pump CABG group (p < 0.05). Postoperative results showed that operative mortality (0.5% in Off-Pump CABG versus 2.0% in On-Pump CABG), renal failure (2.6% in Off-Pump CABG versus 7.0% in On-Pump CABG), and perioperative myocardial infarction (1.5% in Off-Pump CABG versus 1.0% in On-Pump CABG) did not differ significantly. However, Off-Pump CABG had shorter mean operation time (p<0.05), lower mean CK-MB level (p <0.05), lower rate of usage of inotropics (p < 0.05), shorter mean ventilation time (p <0.05), lower perioperative stroke (0% versus 2.0%), and shorter length of stay (p < 0.05) than On-Pump CABG. On-Pump CABG had more distal grafts (p<0.05) than Off-Pump CABG. Although Off-Pump CABG and On-Pump CABG did not show statistical differences in mortality and morbidity was more frequent in CABG. Conclusion: Off-Pump CABG reduces morbidity and favors hospital outcomes. Therefore, Off-Pump CABG is safe, reasonable and may be a preferable operative strategy for high-risk patients.

Airborne Hyperspectral Imagery availability to estimate inland water quality parameter (수질 매개변수 추정에 있어서 항공 초분광영상의 가용성 고찰)

  • Kim, Tae-Woo;Shin, Han-Sup;Suh, Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • This study reviewed an application of water quality estimation using an Airborne Hyperspectral Imagery (A-HSI) and tested a part of Han River water quality (especially suspended solid) estimation with available in-situ data. The estimation of water quality was processed two methods. One is using observation data as downwelling radiance to water surface and as scattering and reflectance into water body. Other is linear regression analysis with water quality in-situ measurement and upwelling data as at-sensor radiance (or reflectance). Both methods drive meaningful results of RS estimation. However it has more effects on the auxiliary dataset as water quality in-situ measurement and water body scattering measurement. The test processed a part of Han River located Paldang-dam downstream. We applied linear regression analysis with AISA eagle hyperspectral sensor data and water quality measurement in-situ data. The result of linear regression for a meaningful band combination shows $-24.847+0.013L_{560}$ as 560 nm in radiance (L) with 0.985 R-square. To comparison with Multispectral Imagery (MSI) case, we make simulated Landsat TM by spectral resampling. The regression using MSI shows -55.932 + 33.881 (TM1/TM3) as radiance with 0.968 R-square. Suspended Solid (SS) concentration was about 3.75 mg/l at in-situ data and estimated SS concentration by A-HIS was about 3.65 mg/l, and about 5.85mg/l with MSI with same location. It shows overestimation trends case of estimating using MSI. In order to upgrade value for practical use and to estimate more precisely, it needs that minimizing sun glint effect into whole image, constructing elaborate flight plan considering solar altitude angle, and making good pre-processing and calibration system. We found some limitations and restrictions such as precise atmospheric correction, sample count of water quality measurement, retrieve spectral bands into A-HSI, adequate linear regression model selection, and quantitative calibration/validation method through the literature review and test adopted general methods.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Comparison of Turfgrass Density, Uniformity and Tiller Characteristics in Mixtures of Overseeded Warm-Season and Cool-Season Grasses (덧파종한 난지형 및 한지형 혼합 식생 잔디밭에서 잔디밀도, 균일도 및 분얼경 특성 비교)

  • Kim, Kyoung-Nam
    • Weed & Turfgrass Science
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 2017
  • The study was initiated to evaluate the effects of overseeding warm-season grass (Zoysia japonica Steud.) with cool-season grasses (CSG) on turfgrass density, uniformity and tiller appearance and to determine turfgrass species and seeding rate applicable for a practical use. Treatments were comprised of Kentucky bluegrass (KB, Poa pratensis L.), perennial ryegrass (PR, Lolium perenne L.), tall fescue (TF, Festuca arundinacea Schreb.) and their mixtures. Overall turfgrass density and uniformity were much better with the overseeded treatments over the control. In early stage after overseeding, the greater the PR in treatments, the greater the turfgrass density and uniformity. But the higher the KB, the lower the density and uniformity. From the middle-stage evaluation, however, we observed the opposite results as compared with early-stage findings. Accordingly, the KB was highest in turfgrass density and uniformity, while the PR lowest. In regards of mixtures, both turfgrass density and uniformity were better with increased KB and decreased PR in overseeding rates. As for a medium-quality mixtures of Korean lawngrass with CSG, it would be the best choice to apply with KB at $50g\;m^{-2}$ and equal combination of KB, PR and TF by 1/3 in mixing at $75g\;m^{-2}$ in terms of sustainable density and uniformity.

Comparison of the Effects of Cyclodextrin-Naringin Inclusion Complex with Naringin on Lipid Metabolism in Mice Fed a High-Fat Diet (고지방식이를 섭취한 마우스에서 나린진과 나린진-사이클로텍스트린 포접화합물의 지질대사에 대한 영향 비교)

  • Jeon, Seon-Min;Choi, Myung-Sook
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.1
    • /
    • pp.20-29
    • /
    • 2010
  • Naringin has antioxidant and antihyperlipidemic properties, however, phenolic compounds including naringin are unstable in the presence of light, heat and oxygen. Beta-cyclodextrin ($\beta$-CD) is a cyclic heptamer composed of seven glucose units that enhances the stability and solubility of molecules through the formation of inclusion complexes. This study was conducted out to compare the effects of CD-naringin (CD-N) inclusion complexes with naringin on lipid metabolism in high fat-fed animals. Male C57BL/6 mice were fed either CD-N (0.048%, w/w) or naringin (N, 0.02%, w/w) in a 20% high-fat (HFC, 15% lard, 5% corn oil, w/w) diet for 10 weeks. Orlistat (Xenical, 0.01%, w/w) was used as a positive control (PC). There were no differences in body weight, food intake, liver and heart weights, plasma triglyceride(TG), leptin, adiponectin, resistin, IL-$1{\beta}$ and IL-6 concentrations, and hepatic $\beta$-oxidation, carnitine palmitoyl transferase(CPT), glucose-6-phosphate dehydrogenase (G6PD) and malic enzyme activities between the HFC and CD-N groups or between the HFC and N groups. However, both CD-naringin and naringin supplementation les to a significant reduction in the epididymal and perirenal white adipose tissue weights, plasma free fatty acid, insulin and blood glucose concentrations, hepatic cholesterol and TG contents and hepatic fatty acid synthase (FAS), phosphatidate phosphohydrolase (PAP) and HMG-CoA reductase activities compared to the HFC group. The plasma HDL-cholesterol concentration was significantly higher in CD-N and N groups than in HF and PC groups. These results indicate that both CD-naringin and naringin supplementation effectively improved plasma and hepatic lipid metabolism without differences between CD-N and naringin groups.

The Effect of Combined Estrogen/calcium Therapy on Bone Metabolism in Ovariectomized Rats I. A Study on Biochemical Parameters in Ovariectomized Rats (에스트로겐/칼슘 혼합요법이 난소절제 쥐의 골대사에 미치는 영향 I. 생화학적 변화에 관한 연구)

  • 이경화;오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.6
    • /
    • pp.993-1005
    • /
    • 1996
  • This study was implemented in order to investigate the effects of dietary calcium-salt, estrogentreatment, and estrogen/calcium treatment on bone metabolism. Ovariectomized rats were used as animal models. Female Sprague-Dawley rats with a body weight of 250~280g were underwent ovariectomy or sham-operation. The ovariectomized rats were divided into 9 different experimental groups including the saline-treated group, the estrogen-treated group, the high calcium salt-treated group, and the estrogen/calcium treated groups and fed for 6 weeks. Creatinine and hydroxyproline in urine were analyzed. Creatinine, calcitonin, osteocalcin, alkaline phosphatase and parathyroid hormone in plasma were also determined. The results of the experiment are as follows : The ovariectomy caused a significant increase in the level of food intake, food effciency ratio and body weight gain in comparison with sham-operation. The overall food intake, food effciency ratio and body weight gain were significantly decreased by estrogen. The ovariectomized animals developed obesity as a result of increased food intake. In addition, estradiol injections suppressed food intake with a concomitant loss in body weight. The level or urinary hydroxyproline, as an indicator or bone resorntion, was higher in the ovariectomized rats compared to sham-opertion, while these decresed in the estrogen/calcium treated group. Parathyroid hormone and calcitonin in the plasma, that were used as the indicator of calcium homeostasis, parathyroid hormone higher in the ovariectomized rats compared to sham-operation. It was lowered by estrogen and high calcium treated groups; thus, estrogen and estrogen/calcium treated groups were decreased by 32% compared to saline treated group. Osteocalcin and alkaline phosphatase which are indicators of bone formation, were significantly higher in ovariectomized group, while this showed to be decreased in the estrogen and the ostrogenicalcium treated groups. Estrogen and estrogen/calcium in ovariectomized rats resulted in lower bone loss. However, estrogen treated group its gradual reduction showed little effect on bone loss, while the gradual reduction of estrogen had a preventive effect on bone loss when the treatment was combined with calcium intensification.

  • PDF

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.