• Title/Summary/Keyword: comparison measurement

Search Result 3,155, Processing Time 0.039 seconds

A Study of The Correlativity in EAV(Electroacupuncture According to Voll)measurement valvues, Sasang Constitution Classfication and CVA(Cerebrovascular accident) (EAV의 측정치(測定値)와 사상체질유형(四象體質類型) 및 중풍(中風)과의 상관성(相關性)에 관한 연구(硏究))

  • Kim, Jong-Weon;Ko, Bung-Hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.7 no.2
    • /
    • pp.59-88
    • /
    • 1995
  • Three groups have participated in this study. 1) The first group consists of 57 patients were who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 2) The second group consists of 37 outpatients who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 3) The third group consists of 76 students of the Oriental Medical School at Kyung Hee University. The following conclusions were made in comparison with EAV measurement values, SaSang Constitution Classfication and CVA. 1. The following conclusions were made in comparison with EAV measurement values and Type(SaSang Constitution Classfication). 1) The analsis of the Correlation in Normal group with EAV measurement values and Type(SaSang Constitution Classfication). 2) The analysis of the correlation in patient group with EAV measurement values showed significant differences in Right meridians(Nerval degeneration vessel, Circulation, Allergy) and in Left meridian(Liver). 3) The analysis of the correlation in Total(Normal+patient)group with EAV measurement values showed significant differences in Right meridians(Large intestine, Nerval degeneration vessel, Circulation, Allergy, Pancreas) and in Left meridians(Lymph vessel, Nerval degeneration vessel, Spleen, liver). 4) The above results showed common-significant differences in Right Allery meridian and in Left Liver meridian. 2. The analysis of the correlation in EAV measurement values and Group (Cerebrovascular accident) showed significant differences in Right meridians(Lymph vessel, Lung, Nerval degeneration vessel, Allergy, Paren & Epith. degeneration vessel, Triple warmer, Heart, Pancreas, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Heart, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Bile duct, Kidney). 3. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS)showed significant differences in Left Stomatch meridian. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS) about the differance of right measurement values and left measurement values showed significant differences in Nerval degeneration vessel, Stomatch, Gall bladder & Bile duct, Kidney and Urinary Bladder meridians. 4. The analysis of the correlation in EAV measurement values and Compl(GROUPS according to COMPLICATION with CVA)showed significant differences in Right meridians(Lymph vessel, Articular degeneration vessel, Fatty degeneration vessel) and in Left meridians(Lung, Stomatch, Fatty degeneration vessel). 5. The analysis of the correlation in Type and MORPHOROGICAL DIAGRAMING (HTOUPS according to MORPHOROGY) showed significant differences in Cranium region, Chest region, Stomatch region and Umbilicum region. 6. The analysis of the correlation in BAZ measurement values and Group(Cerebral Vascular Attack)showed significant differences, the analysis on the correlation of BAZ measurement values and Type(SaSang Constitution Classfication) didn't show any significant differences. 7. In comparison with Actual measurement vales and Voll's measurement values, BAZ measurement values agree with Voll's measurement values but CMP measurement values lower than the Voll's measurement values. Later We have to research further about classifications of race, age, sex etc. The EAV measurement values have Group(Cerebrovascular accident) more correlative than Type(SaSang Constitution Classfication). The EAV may well be that it will be used as an accessory method in SaSang Constitution Classfication and as a diagnostic method in medicine too.

  • PDF

Near-Field Rx-Measurement for Active Phased Array of Digital Radar Using Calibration Path (보정 경로를 활용한 디지털 레이더의 능동 위상 배열 근접전계 수신시험)

  • Yu, Je-Woo;Chae, Heeduck;Park, Jongkuk;Lim, Jae-Hwan;Kim, Duckhwan;Jin, Hyoung-Seog;Kim, Han-Saeng
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.504-511
    • /
    • 2016
  • In this paper, the method is proposed that the equivalent result can be obtained by compensating the variation of gain and phase in the comparison with the result of near-field measurement which is obtained in the steady state, although the gain and phase variation of rx-channels occurred in the near-field rx-measurement of digital active phased array antenna. The proposed concept has the time section for monitoring the state of the rx-channels through the calibration path in the measurement timeline, and is the method for compensating the variation of state. For validating the proposed method, the fabricated X-band digital active phased array antenna and the planar near-field measurement facility is utilized. The proposed method is validated in the comparison with the compensated pattern which the unstable state of rx-channels is calibrated and the reference pattern obtained under the steady state of the rx-channels.

Comparison of the PM10 Concentration in Different Measurement Methods at Gosan Site in Jeju Island (제주도 고산 측정소의 미세먼지 측정방법에 따른 질량농도 비교)

  • Shin, So-Eun;Kim, Yong-Pyo;Kang, Chang-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.421-429
    • /
    • 2010
  • The reliability of the measurement of ambient trace species is an important issue, especially, in background area such as Gosan in Jeju Island. In a previous episodic study, it was suggested that the PM10 measurement result by the gravimetric method(GMM) was not in agreement with the result by the ${\beta}$-ray absorption method(BAM). In this study, a systematic comparison was carried out for the data between 2001 and 2008 at Gosan(GMM and BAM) and Jeju city (BAM) which is near to Gosan. It was found that at Gosan the PM10 concentration by BAM was higher than GMM and the correlation between them was low. The BAM results at Gosan and Jeju city showed similar trend implying the discrepancy at Gosan was not caused by instrumental problem of the BAM at Gosan. Based on the previous studies two probable reasons for the discrepancy are identified; (1) negative measurement error by the evaporation of volatile ambient species at the filter in GMM such as nitrate and ammonium and (2) positive error by the absorption of water vapor during measurement in BAM. There was no heater at the inlet of BAM at Gosan during the sampling period. Based on the size-segregated measurement data, it was identified that the evaporation error was minor, if any. The relationship between the two methods did not vary with the ambient relative humidity. Thus, at present, it is not clear why the discrepancy had been occurring and when using the PM10 data at Gosan, one should be aware the possible errors.

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Verification of Long-distance Vision-based Displacement Measurement System (장거리 영상기반 변위계측 시스템 검증)

  • Kim, Hong-Jin;Heo, Suk-Jae;Shin, Seung-Hoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2018
  • The purpose of this study is to verify the long - range measurement performance for practical field application of VDMS. The reliability of the VDMS was verified by comparison with the existing monitoring sensor, GPS, Accelerometer and LDS. It showed the ability to accurately measure the dynamic displacement by tracking a motion of free vibration of target. And using the PSD function of measured data, the results in the frequency domain were also analyzed. We judged that VDMS is able to identify the higher system mode and has sufficient reliability. Based on the reliability verification, we conducted tests for long-distance applicability for actual application of VDMS. The distance from the stationary target model structure was increased by 50m interval, and the maximum distance was set to 400m. From the distance of 150m, the image obtained by the commercial camcorder has an error in the analysis, so the measured displacement comparison was performed between the LDS and the refractor telescope measurement results. In the measurement results of the displacement area of VDMS, the data validity was deteriorated due to the data shift by the external force and the quality degradation of the enlarged image. However, even under the condition that the effectiveness of the displacement measurement data of VDMS is low, the first mode characteristic included in the free vibration of the object is clearly measured. If the influence from the external environment is controlled and stable data is collected, It is judged that reliability of long-distance VDMS can be secured.

A Study of the Optimal Displacement Analysis Algorithm for Retaining Wall Displacement Measurement System Based on 2D LiDAR Sensor (2D LiDAR 센서 기반 흙막이 벽체 변위 계측 시스템의 최적 변위 분석 알고리즘 연구)

  • Kim, Jun-Sang;Lee, Gil-yong;Yoou, Geon hee;Kim, Young Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.2
    • /
    • pp.70-78
    • /
    • 2023
  • Inclinometer has several problems of 1)difficulty installing inclinometer casing, 2) measuring 2D local lateral displacement of retaining wall, 3) measurement by manpower. To solve such problems, a 2D LiDAR sensor-based retaining wall displacement measurement system was developed in previous studies. The purpose of this study is to select a displacement analysis algorithm to be applied in the retaining wall displacement measurement system. As a result of the displacement analysis algorithm selection, the M3C2 (Multiple Model to Model Cloud Comparison) algorithm with a displacement estimation error of 2mm was selected as the displacement analysis algorithm. If the M3C2 algorithm is applied in the system and the reliability of the displacement analysis result is secured through several field experiments. Convenient management of the displacement for the retaining wall is possible in comparison with the current measurement management.

A Standard Method for Progress Measurement in a Petrochemical Plant EPC Project (석유화학 플랜트 EPC 사업의 진도율 산정표준의 제안)

  • Cho, Hong-Yeon;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.4
    • /
    • pp.77-87
    • /
    • 2011
  • In proportion to continuing growth of overseas plant market and the trend of its mega scale of the project, the importance of management is significantly emphasized for the successful execution of the project. And it is recognized that progress control is the most important management item amongst the others in the management. Progress control is importance of progress measurement for performance measurement and process control of project, but it is hardly obtainable securing the objectivity in the progress measurement since the progress measurement are being applied differently in accordance with the project conditions and the experience level of the person in charge for the progress control. This study has conducted as following to propose a standard method for progress measurement in a petrochemical plant protect. Domestic and overseas plant projects are investigated variously with the applied method of progress measurement, and the deduced problem of progress measurement. And then standard method for progress measurement of engineering, procurement, construction and commissioning has been proposed according to comparison and analysis of practices in domestic & overseas plant project, procedures for progress control in the globally reputed petrochemical client, company rules and recommendation of the expert in progress control.

  • PDF

Effects of Posture Correction Training on Pulmonary Function with Turtle Neck Syndrome (자세교정훈련이 거북목증후군의 폐기능에 미치는 영향)

  • Jang, Cheul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.183-192
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the impact of postural correction training on pulmonary function on 28 college students suspected of turtle neck syndrome, and the following conclusions were obtained. Methods : Turtle neck syndrome suspicion 28 person were randomly divided into a posture training group (n = 14) and group that does not perform posture training (n = 14). Respiratory function was measured by SPIROVIT SP-1 and respiratory gas analyzer. The posture training group performed balloon blowing and stair climbing after 20 minutes of posture training, and the group without posture training carried out balloon blowing training and stair climbing. Five times a week and for two weeks. Results : 1. The comparison of the FVC before and after experiments caused by balloon blowing showed a higher level of effortful pulmonary function in the control group than in the experimental group. 2. Comparison of PEFs before and after the experiment by balloon blowing showed that the experimental group's peak flow rate was higher than that of the control group. 3. Comparison of the FIVC before and after experiments with balloon blowing showed that the comparison of the FIVC showed a higher level of effortless intake pulmonary function in the control group than in the experimental group. 4. The comparison of the maximum ventilation volume(VE) before and after the experimental gas measurement showed that the maximum ventilation rate of the experimental group was higher than that of the control group. 5. The comparison of pre-test and post-test heart rate(HR) by breath gas measurement showed that the heart rate of the control group was higher than that of the experimental group. Conclusion : the results of this study showed that postural correction training, balloon blowing training, and stair climbing could have a positive impact on improving pulmonary function. However, the two-week experiment conducted five times a week showed an increase in pulmonary function, but it was difficult to see the effect due to the short study period. Therefore, it is hoped that later studies will be conducted more systematically on the effects of breathing exercises on improving pulmonary function after post-postural correction training for patients with pulmonary function problems.

A Comparative Study of a Variable Overlap-area Type and Conventional Types in the Inductive Precision Position Measurement System (자속경로 단면적 및 공극변화를 이용한 인던턴스형 초정밀 변위측정 시스템)

  • Choe, Dong-Jun;Choe, In-Muk;Kim, Su-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.254-259
    • /
    • 2002
  • A variable air-gap type system is widely used for inductive precision position measurement systems. This type transducer has high sensitivity but lacks a linear measurement range due to structural nonlinearity. Furthermore, as measurement range increases, linearity error is also increased. The alternative is a variable overlap-area type system. The sensitivity of this type is determined by the initial air-gap dimension, keeps the original value and does not deteriorate linearity in spite of the variations of the measuring range.

Uncertainty Analysis of Hyung San River Discharge due to the methods of Discharge Measurement (유량측정방법에 따른 형산강유량의 불확실도 분석)

  • Seo, Kyu-Woo;Kim, Su-Hyun;Kim, Dai-Gon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1538-1542
    • /
    • 2005
  • This study is to secure more accurate data of the discharge on the measurement by gaining a reliable hydrological data through the comparison the present method of measuring them and the other way that is based ISO. This study suggests the applicable measurement method of the discharge that has reliance through general elements and the analysis of uncertainty by comparing and assaying the data of the Hyung San River that is measured by the present standard. The result of this study makes us realize that we should complement the measurement method of the discharge securing the reliable and accurate hydrological data Hydrological data is very important things to perform domestic river works or install some structure in river or coast. Securing reliable and accurate hydro-data and making a thesis should go on in other to do any construction in river or coast.

  • PDF