• 제목/요약/키워드: comparison measurement

검색결과 3,147건 처리시간 0.026초

A Development of Recoil & Counter Recoil Motion Measurement System Using LVDT

  • Park, Ju-Ho;Hong, Sung-Soo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권3호
    • /
    • pp.214-219
    • /
    • 2000
  • This paper presents a recoil and counter recoil motion measurement system using linear variable differential transformers (LVDT). The output of the LVDT is obtained from the differential voltage of the secondary transformers. Since a transducer core is attached to the motion body, the output is directly proportional to the movement length of the core. Displacement, velocity and acceleration are measured from the LVDT. With a comparison between the measurement result and the reference value obtained by the highly accurate Vernier calipers, it is proved that the measurement system with the LVDT is applicable to the test of the moving part of the mechanism with better accuracy.

  • PDF

Centralized Kalman Filter with Adaptive Measurement Fusion: its Application to a GPS/SDINS Integration System with an Additional Sensor

  • Lee, Tae-Gyoo
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권4호
    • /
    • pp.444-452
    • /
    • 2003
  • An integration system with multi-measurement sets can be realized via combined application of a centralized and federated Kalman filter. It is difficult for the centralized Kalman filter to remove a failed sensor in comparison with the federated Kalman filter. All varieties of Kalman filters monitor innovation sequence (residual) for detection and isolation of a failed sensor. The innovation sequence, which is selected as an indicator of real time estimation error plays an important role in adaptive mechanism design. In this study, the centralized Kalman filter with adaptive measurement fusion is introduced by means of innovation sequence. The objectives of adaptive measurement fusion are automatic isolation and recovery of some sensor failures as well as inherent monitoring capability. The proposed adaptive filter is applied to the GPS/SDINS integration system with an additional sensor. Simulation studies attest that the proposed adaptive scheme is effective for isolation and recovery of immediate sensor failures.

자기탄성체 리본의 공진을 이용한 인-라인 오일 점도센서 (In-line Oil Viscosity Sensor Implementing An Elastomagnetic Ribbon Resonance)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제26권2호
    • /
    • pp.97-104
    • /
    • 2010
  • A new magnetoelastic technique of oil viscosity measurement, where the oil viscosity is estimated by frequency shift of natural oscillations of magnetoelastic ribbon, is implemented in this study. Laboratory tests of the detector prototype are performed for measurement of viscosity of base synthetic and mineral oils. It was found that measurement accuracy was better when damping factor was estimated in comparison with accuracy of frequency of damped oscillations. Thus the oil viscosity was calibrated as a function of number of pulses of the damped oscillations of magnetoelastic ribbon. Result generally showed that developed detector is promising for in line oil viscosity measurement in wide viscosity range from 10 cSt up to 600 cSt, while the viscosity measurement was relatively instable when the viscosity of test oil was over 400 cSt.

Further Development of Vision-Based Strain Measurement Methods to Verify Finite Element Analyses

  • Kim, Hyung jong;Lee, Daeyong
    • 소성∙가공
    • /
    • 제5권4호
    • /
    • pp.343-352
    • /
    • 1996
  • One of the preferred methods that can be used to verify the results of finite element analysis is to measure surface strains of the deformed part for purpose of direct comparison with simulation results. Instead of using the usual manual method the vision-based measurement method is capable of determining surface geometry and strain from the deformed grid pattern automatically with the help of a computer. To obtain strain distribution over an area, the coordinates of such a surface grid are determined from the multiple video images by applying the photogrammetry principle. Methods to improve the overall accuracy of the vision-based strain measurement system are explored and the possible accuracies that can be attained by such a measurement method are discussed. A major emphasis is placed on the initial grid application method its accuracy and ease of subsequent image processing. Finite element analyses of limiting dome height(LDH) test are carried out and the results of them are compared with exsperimen-tal data.

  • PDF

동적 및 정적 실험 방법으로 평가한 지반의 초기 강성 비교 (Comparison of dynamic and static methods in the measurement of the initial stiffness of soil)

  • 주진현;정영훈;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.940-951
    • /
    • 2009
  • A comparative study on dynamic and static measurement of initial stiffness was conducted. Because soil stiffness decreases even at very small strains, the initial stiffness has been measured by dynamic tests using shear wave velocity measurement. On the other hand, due to the advance of local strain measurement, the triaxial testing device is capable of measuring the static initial stiffness. It has been known that initial stiffness measured by static triaxial tests is generally lower than that measured by dynamic tests possibly due to the limitation of static measurement of displacement at very small strains. This study presents experimental results indicating that the elastic shear moduli could be the same both in dynamic and static measurements owing to the soil anisotropy induced by anisotropic stresses.

  • PDF

Empirical Comparison of Measurement Methods for Educational Service Quality

  • Kang, Sung;Choi, Kyung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권3호
    • /
    • pp.801-809
    • /
    • 2008
  • Nowadays almost all universities are endeavoring to improve the quality of education offered. The quality of education that is provided should be measured beforehand. This study examined three methods, SERVQUAL, SERVPERF and Lee and Yun(2004)'s method of measuring service quality: SERVQUAL, SERVPERF are well known and the most commonly used measurement of the quality of education offered and the Lee and Yun(2004)'s method measures service quality using fuzzy numbers. As a result of this research, SERVQUAL was proven to be the most efficient method to measure the quality of education offered. Even though, more actual analysis related to this study should be followed, the research is meaningful in a way that it provided clues and reasons for the study.

  • PDF

공기 중 포름알데히드 측정을 위한 크로모트로핀산법과 DNPH/HPLC방법의 비교.평가 (Comparison of Chromotropic Acid Method and DNPH-HPLC Method for the Measurement of Formaldehyde in the Air)

  • 황윤정;박상곤;백성옥
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.519-524
    • /
    • 1998
  • Formaldehyde is known to have adverse health effects, and is also found to be a product of atmospheric. photochemical reaction%. Several methods have been employed for the measurement of formaldehyde. Among them, two common methods are comparatively evaluated in this study, i.e. the chromotropic acid method and the HPLC method coupled with 2,4- dinitrophenylhydrazine (DNPH) derivatization of carbonyl compounds. Method evaluation and validation were performed with respect to repeatability, linearity, collection efficiency, and recovery efficiency. Comparison of formaldehyde concentrations measured simultaneously in the field using the two (n=20) and 35.8%, respectively. Overall, the measured levels by chromotropic acid method appeared to ice significantly higher than those by DNPH-HPLC method, indicating a positive interference due to the other aldehydes collected together with formaldehyde.

  • PDF

Results of the key comparison in absolute pressure from 1 Pa to 1000 Pa

  • Hong, Seung-Soo;Shin, Yong-Hyeon;Chung, Kwang-Hwa;A. P. Miiller
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.109-115
    • /
    • 2002
  • This paper describes a CCM key comparison of low absolute-pressure standards at seven National Measurement Institutes that was carried out during the period March 1998 to September 1999 in order to determine their degrees of equivalence at pressures in the range 1 Pa to 1000 Pa. The Korea Research Institutes of Standards and Science(KRISS) participated from 10 Pa to 1000 Pa pressure range in 1999. The primary standards, which represent two principal measurement methods, included five liquid-column manometers and four static expansion systems. The transfer standard package consisted of four high-precision pressure transducers, two capacitance diaphragm gauges to provide high resolution at low pressures, and two resonant silicon gauges to provide the required calibration stability.

  • PDF

파열음 폐쇄 구간과 국어 경음의 기저구조 (Closure duration of plosives and the underlying representation of tense consonants in korean)

  • 이상직
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2007년도 한국음성과학회 공동학술대회 발표논문집
    • /
    • pp.230-233
    • /
    • 2007
  • In the literature on the tense consonants in Korean, it has been proposed that this consonant is underlyingly represented by a single consonant (the singleton hypothesis) and that it is represented by a sequence of two lenis consonants (the geminate hypothesis). One piece of the empirical evidence supporting the geminate hypothesis is that the closure duration of tense consonants in intervocalic position is more than twice as long in comparison with their lenis counterparts. In this paper, we report on the closure duration of three types of plosives in various phonotactically permitted contexts in Korean. The results of the measurement show that the duration of the tense consonants in post-sonorant contexts is reduced by a third in comparison with that of the intervocalic ones. These temporal differences suggest that the measurement of closure durations in intervocalic position alone is not sufficient to sustain the geminate hypothesis.

  • PDF

유량측정을 위한 초음파 전파경로 비교 (Comparison of Ultrasonic Paths for Flow Rate Measurement)

  • 김주완;박춘광;김진오;박두식
    • 한국소음진동공학회논문집
    • /
    • 제25권7호
    • /
    • pp.455-461
    • /
    • 2015
  • The paper deals with the accuracy comparison between two kinds of ultrasonic paths for flow rate measurement. In the Z-path, two transducers are installed on the opposite sides of each other on a pipe, and the ultrasonic waves generated at one transducer propagate to arrive at the other one only by refraction. In the V-path, two transducers are installed on one side of a pipe, and the ultrasonic waves reflected at the inner wall of the pipe are received. Transit times were confirmed to identify the propagation paths by comparing the theoretically calculated results and measured ones. The flow rate measurements with two kinds of ultrasonic paths appeared very similar. It would be possible to select either of the paths by considering the advantages and disadvantages.