Modification of the fast fourier transform-based method by signal mirroring for accuracy quantification of thermal-hydraulic system code

  • Ha, Tae Wook;Jeong, Jae Jun;Choi, Ki Yong
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.1100-1108
    • /
    • 2017
  • A thermal-hydraulic system code is an essential tool for the design and safety analysis of a nuclear power plant, and its accuracy quantification is very important for the code assessment and applications. The fast Fourier transform-based method (FFTBM) by signal mirroring (FFTBM-SM) has been used to quantify the accuracy of a system code by using a comparison of the experimental data and the calculated results. The method is an improved version of the FFTBM, and it is known that the FFTBM-SM judges the code accuracy in a more consistent and unbiased way. However, in some applications, unrealistic results have been obtained. In this study, it was found that accuracy quantification by FFTBM-SM is dependent on the frequency spectrum of the fast Fourier transform of experimental and error signals. The primary objective of this study is to reduce the frequency dependency of FFTBM-SM evaluation. For this, it was proposed to reduce the cut off frequency, which was introduced to cut off spurious contributions, in FFTBM-SM. A method to determine an appropriate cut off frequency was also proposed. The FFTBM-SM with the modified cut off frequency showed a significant improvement of the accuracy quantification.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

Sharpness-aware Evaluation Methodology for Haze-removal Processing in Automotive Systems

  • Hwang, Seokha;Lee, Youngjoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.390-394
    • /
    • 2016
  • This paper presents a new comparison method for haze-removal algorithms in next-generation automotive systems. Compared to previous peak signal-to-noise ratio-based comparisons, which measure similarity, the proposed modulation transfer function-based method checks sharpness to select a more suitable haze-removal algorithm for lane detection. Among the practical filtering schemes used for a haze-removal algorithm, experimental results show that Gaussian filtering effectively preserves the sharpness of road images, enhancing lane detection accuracy.

지적세부측량을 위한 위성영상의 활용 (Utilization of Satellite Image for Cadastral Surveying)

  • 이종출;차성렬;김남식;강윤성
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.535-538
    • /
    • 2004
  • Recently, Ministry of Government Administration and Home Affairs and Local Governments drafted plan to digitize cadastral maps for making effective land management and development. Cadastral map have difference in comparison with actual area's boundary since they used long time and continuously. In this study, verification of accuracy has concerned in comparison with cadastral map and IKONOS satellite image which has geometrical correction.

  • PDF

국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰 (Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review)

  • 이유승
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.370-378
    • /
    • 2021
  • 목적: 본 연구의 목적은 CAD-CAM 방식으로 제작한 RPD framework의 제조 과정 및 제작 방법에 따른 적합도를 문헌 고찰을 통해 평가하는 것이다. 재료 및 방법: 다음의 PICO (patient, intervention, comparison, and outcome) 질문과 관련한 특정 키워드를 이용하여 PubMed 데이터베이스 상에서 포괄적인 문헌 검색을 시행하였다: "제조 과정 및 제작 방식에 따라 디지털 RPD framework의 정확도에 차이가 있는가?" 결과: 총 7개의 문헌이 선택되었으며, 이 중 두 문헌에서 구강스캔과 모형스캔을 이용한 디지털 RPD framework의 정확도에 관하여 비교하였으나, 일관된 결과를 얻지 못하였다. 제작 방식에 따른 비교 문헌에서는 적층 가공 또는 절삭 가공을 통해 제작된 RPD framework 모두 임상적으로 허용가능한 수준의 정확도를 보였으며, PEEK (Polyetheretherketone) milling RPD framework가 전통적 주조방식으로 제작하거나 3D 프린팅으로 제작한 RPD framework보다 높은 적합도를 보였다. Milling RPD framework에서는 direct 방식으로 제작한 경우에 indirect 방식의 경우보다 우수한 적합도가 관찰되었으나, 3D 프린팅 RPD framework에서는 indirect 방식으로 제작한 경우에 더 높은 적합도를 보였다. 결론: CAD-CAM 기술을 이용하여 제작된 디지털 RPD framework는 제조 과정이나 방식에 관계없이 임상적으로 허용되는 수준의 정확도를 보였다. 구강스캔 또는 모형스캔의 디지털 인상 채득 방법에 따라서는 일관된 결과가 보고되지 않았으며, 추후 연구가 필요하다.

Classification of tree species using high-resolution QuickBird-2 satellite images in the valley of Ui-dong in Bukhansan National Park

  • Choi, Hye-Mi;Yang, Keum-Chul
    • Journal of Ecology and Environment
    • /
    • 제35권2호
    • /
    • pp.91-98
    • /
    • 2012
  • This study was performed in order to suggest the possibility of tree species classification using high-resolution QuickBird-2 images spectral characteristics comparison(digital numbers [DNs]) of tree species, tree species classification, and accuracy verification. In October 2010, the tree species of three conifers and eight broad-leaved trees were examined in the areas studied. The spectral characteristics of each species were observed, and the study area was classified by image classification. The results were as follows: Panchromatic and multi-spectral band 4 was found to be useful for tree species classification. DNs values of conifers were lower than broad-leaved trees. Vegetation indices such as normalized difference vegetation index (NDVI), soil brightness index (SBI), green vegetation index (GVI) and Biband showed similar patterns to band 4 and panchromatic (PAN); Tukey's multiple comparison test was significant among tree species. However, tree species within the same genus, such as $Pinus$ $densiflora-P.$ $rigida$ and $Quercus$ $mongolica-Q.$ $serrata$, showed similar DNs patterns and, therefore, supervised classification results were difficult to distinguish within the same genus; Random selection of validation pixels showed an overall classification accuracy of 74.1% and Kappa coefficient was 70.6%. The classification accuracy of $Pterocarya$ $stenoptera$, 89.5%, was found to be the highest. The classification accuracy of broad-leaved trees was lower than expected, ranging from 47.9% to 88.9%. $P.$ $densiflora-P.$ $rigida$ and $Q.$ $mongolica-Q.$ $serrata$ were classified as the same species because they did not show significant differences in terms of spectral patterns.

Reid Colposcopic Index Evaluation: Comparison of General and Oncologic Gynecologists

  • Aue-Aungkul, Apiwat;Suprasert, Prapaporn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5001-5004
    • /
    • 2015
  • The Reid colposcopic index (RCI) helps physicians for interpret the results of colposcopic examination. To compare the accuracy of RCI in colposcopic evaluation between general and oncologic gynecologists, this prospective trial was conducted by invited women over 20 years of age who were scheduled for a colposcopy at Chiang Mai University Hospital between August, 2008 and May, 2014 to participate. Pregnant patients or those having a history of hysterectomy or conization were excluded. During the colposcopy, all patients were simultaneously evaluated by general and oncologic gynecologists utilizing the RCI. Further management with either a biopsy or LEEP in each patient was dependent on the decision of the attending oncologic gynecologist. The accuracy of the RCI in diagnosing HSIL or more was calculated by the comparison with the final histology. Finally, 135 patients were recruited into this study. The sensitivity, specificity, PPV, NPV, and accuracy of RCI in diagnosing HSIL or more in general gynecologists were 45.2%, 80.7%, 41.1%, 83.2% and 72.6% while in the oncologic gynecologists were 51.6%, 85.6%, 51.6%, 85.6% and 77.8%, respectively. The difference in accuracy between evaluator groups was not significant (p-value=0.28). Of 3 patients with invasive cervical cancer, all were undetected by the general gynecologists using RCI while only 1 invasive cervical cancer was missed via RCI by the oncologic gynecologists. We conclude that RCI could be used by general gynecologists in provincial hospitals with major concerns about missing invasive cervical cancer. A short training period regarding colposcopy might help to resolve this problem.

Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters

  • Hussein, Mostafa Omran;Hussein, Lamis Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권3호
    • /
    • pp.150-161
    • /
    • 2022
  • PURPOSE. The purpose of the study was to assess the influence of build orientations and density of support structures on the trueness of the 3D printed removable partial denture (RPD) frameworks. MATERIALS AND METHODS. A maxillary Kennedy class III and mandibular class I casts were 3D scanned and used to design and produce two 3D virtual models of RPD frameworks. Using digital light processing (DLP) 3D printing, 47 RPD frameworks were fabricated at 3 different build orientations (100, 135 and 150-degree angles) and 2 support structure densities. All frameworks were scanned and 3D compared to the original virtual RPD models by metrology software to check 3D deviations quantitatively and qualitatively. The accuracy data were statistically analyzed using one-way ANOVA for build orientation comparison and independent sample t-test for structure density comparison at (α = .05). Points study analysis targeting RPD components and representative color maps were also studied. RESULTS. The build orientation of 135-degree angle of the maxillary frameworks showed the lowest deviation at the clasp arms of tooth 26 of the 135-degree angle group. The mandibular frameworks with 150-degree angle build orientation showed the least deviation at the rest on tooth 44 and the arm of the I-bar clasp of tooth 45. No significant difference was seen between different support structure densities. CONCLUSION. Build orientation had an influence on the accuracy of the frameworks, especially at a 135-degree angle of maxillary design and 150-degree of mandibular design. The difference in the support's density structure revealed no considerable effect on the accuracy.

Basic Study on the Comparison of Performance of α-β-γ filter and Kalman Filter for use in a Tracking Module for ARPA system on Board High Dynamic Warships

  • Njonjo, Anne Wanjiru;Pan, Bao-Feng;Jeong, Tae-Gweon
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.302-304
    • /
    • 2016
  • The purpose of this paper is to draw comparison between the performance of ${\alpha}-{\beta}-{\gamma}$ filter and Kalman filter of a tracking module for ARPA system on board high dynamic warship. The comparison is based on the filters' capability to reduce residual error and maintain a stable transient response. The residual error is computed from the difference between the observed the predicted positions for the entire tracking period. The results indicate that the Kalman filter has a higher tracking accuracy compared to the optimal ${\alpha}-{\beta}-{\gamma}$ filter. However, both filters have a similar transient response.

  • PDF

LANDSAT-5의 TM과 MSS 데이타의 비교에 관한 연구 -인천지역의 토지이용분류를 중심으로- (A Study on the Comparison of LANDSAT-5 TM and MSS Data -laying stress on the landuse mapping of Incheon area-)

  • 안철호;박병욱
    • 한국측량학회지
    • /
    • 제4권2호
    • /
    • pp.27-41
    • /
    • 1986
  • 본 연구에서는 LANDSAT- 5호의 TM과 MSS 데이타를 비교분석함으로서 TM 데이타의 활용방안에 대한 검토를 하고자 하였다. TM과 MSS 데이타의 비교는 인천지역의 토지이용분류 결과를 중심으로 이루어졌으며, 아울러 화상강조처리의 방법에 따른 정확도의 비교도 행하였다. 연구결과, 토지이용분류에 있어서 TM 데이타가 MSS보다 약 20%의 정확도 향상을 가져왔으며, TM 화상의 강조처리에서는 평활화처리가 효과적이었음을 알 수 있었다.

  • PDF