• 제목/요약/키워드: community drinking water

검색결과 102건 처리시간 0.022초

일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구 (A Study on the Drinking Water Quality and Contamination Sources in a Rural Area)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

수도관 재질에 따른 생물막 형성 미생물의 Community-Level Physiological Profile(CLPP) 특성 (Characteristics of Community-Level Physiological Profile (CLPP) of Biofilm Microorganisms Formed on Different Drinking Water Distribution Pipe Materials)

  • 박세근;이현동;김영관
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.431-441
    • /
    • 2006
  • This study investigated the physiological characteristics of biofilm microorganisms formed onto the different drinking water distribution pipe surfaces. The simulated drinking water distribution pipe system which had several PVC, STS 304, and GS coupons was operated at flow velocity of 0.08 m/sec (Re 1,950) and 0.28 m/sec (Re 7,300), respectively. At velocity of 0.08 m/sec, the number of viable heterotrophic bacteria in the biofilm over the 3 months of operation averaged $3.3{\times}10^4$, $8.7{\times}10^4$, and $7.2{\times}10^3CFU/cm^2$ for PVC, STS, and GS surfaces, respectively. The number of attached heterotrophic bacteria averaged $1.4{\times}10^3$, $5.6{\times}10^2$, and $6.5{\times}10^2CFU/cm^2$ on PVC, STS, and GS surfaces at the system with relatively high flow velocity of 0.28m/sec. The changes of physiological profile of biofilm-forming microorganisms were characterized by community-level assay that utilized the Biolog GN microplates. Biofilms that formed on different pipe surfaces displayed distinctive patterns of community-level physiological profile (CLPP), which reflected the metabolic preference for different carbon sources and/or the utilization of these carbon sources to varying degrees. The CLPP patterns have shown that the metabolic potential of a biofilm community was different depending on the pipe material. The effect of the pipe material was also characterized differently by operation condition such as flow rate. At flow velocity of 0.08 m/sec, the metabolic potential of biofilm microorganisms on GS surface showed lower levels than PVC and STS biofilms. For biofilms on pipe material surfaces exposed to water flowing at 0.28 m/sec, the metabolic potential was in order of PVC>GS>STS. Generally, the levels of the bacterial biofilm's metabolic potentials were shown to be notably higher on pipe surfaces exposed to water at 0.08 m/sec when compared to those on pipe surfaces exposed to water at 0.28 m/sec.

The Presence of Significant Methylotrophic Population in Biological Activated Carbon of a Full-Scale Drinking Water Plant

  • Kim, Tae Gwan;Moon, Kyung-Eun;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권12호
    • /
    • pp.1774-1778
    • /
    • 2013
  • Methylotrophs within biological activated carbon (BAC) systems have not received attention although they are a valuable biological resource for degradation of organic pollutants. In this study, methylotrophic populations were monitored for four consecutive seasons in BAC of an actual drinking water plant, using ribosomal tag pyrosequencing. Methylotrophs constituted up to 5.6% of the bacterial community, and the methanotrophs Methylosoma and Methylobacter were most abundant. Community comparison showed that the temperature was an important factor affecting community composition, since it had an impact on the growth of particular methylotrophic genera. These results demonstrated that BAC possesses a substantial methylotrophic activity and harbors the relevant microbes.

농촌지역 개인소유 음용수와 간이상수도의 수질에 대한 비교 연구 (Comparison of Water Quality Between Private and Simple-Piped Drinking Water Supply in Rural Community)

  • 이진헌;이인숙
    • 한국환경보건학회지
    • /
    • 제20권1호
    • /
    • pp.54-61
    • /
    • 1994
  • This study was carried out to investigate the degree of contamination in private-drinking water supply (PDWS) and simple-piped water supply (SPWS), and to compare of water quality between them for 3 years from 1990 to 1992. The results of the study were as follows: 1. Private-drinking water supply (PDWS) (1) Field-Site (ㄱ) The items which were very significantly over the criteria (p<0.01), were temp., pH, NO-N, standard plate count (S.P.C.) and Coliform. (ㄴ) No. of households which were over the criteria, were 11.2~51.7% in temp., pH, NH$_3$-N and NO$_2$-N, and 83.1~93.3% in NO-N, S.P.C. and Coliform. (2) Moutain-Site (ㄱ) The items which were over the criteria, were NO$_2$-N (p<0.05), S.P.C. (p<0.01) and Coliform (p<0.01). (ㄴ) No. of households which were over the criteria, were 33.6 ~ 75.6% in NO$_2$-N, S.P.C. and Coliform. (3) No. of households which were fit to the criteria of all items, were 9.0% in field-site and 14.1% in mountain-site. 2. Simple-piped water supply (SPWS) (1) The items which were very significantly over the critera (p<0.01), were standard plate count (S.P.C.) and Coliform. (2) The water qualities of adjacent and remote samples were better than those of source samples. (3) Residual chloride was not detected in any sample. In conclusion, rural community requires to be continually performed the policy of safety drinking water supply, and to be devised an epoch-making counterplan for the level-up of simple-piped water supply (SPWS), espically on the method of disinfection.

  • PDF

지하수 세균 군집의 유전적 다양성 (The Genetic Diversity of Bacterial Communities in the Groundwater)

  • 김여원;민병례;최영길
    • 환경생물
    • /
    • 제18권1호
    • /
    • pp.53-61
    • /
    • 2000
  • 서울시 소재 지하수 중 중금속으로 오염되어 음용수 이외의 생활 용수로 사용하고 있는 1개 정점과 음용수로 사용하고 있는 1개 정점, 대조군으로 강화도 천연 동굴의 1개 정점을 대상으로 실험을 실시하였다. 지하수 세균군집의 유전적 다양성의 변화를 보기 위해 지하수 세균 군집에서 16SrDNA를 증폭하는 primer로 PCR(polymerase chain reaction)을 실시한 후 ARDRA(amplified ribosomal DNA restriction analysis) 지문 분석으로 비교하였다. 16S rDNA를 증폭하여 제한효소 지문분석을 한 결과 in situ와 음용수에서 유전적 다양성이 상대적으로 크게 나타났다. 지하수 세균 군집의 ARDRA지문 분석은 상이한 환경과 서식지를 반영한 유전적 차이를 빠르게 비교 분석할 수 있었으며 지하수의 오염도에 따른 미생물의 다양성(천연 동굴>음용수>오염수)을 확인할 수 있었다.

  • PDF

김해시 수돗물불소농도조정사업 확대 시행에 대한 시민들의 인식과 찬성에 미치는 요인 (Perception and Associated Factors of Primary Schoolchildren's Parents Concerning Approval on the Expansion Implementation of Community Water Fluoridation Program in Gimhae, Korea)

  • 이정화;김만경;김민지;김진삼;김진범
    • 보건교육건강증진학회지
    • /
    • 제27권4호
    • /
    • pp.113-121
    • /
    • 2010
  • Objectives: The study sought to identify the perception of schoolchildren's parents concerning an approval on the expansion implementation of community water fluoridation program in Gimhae, Korea. Methods: Questionnaires were distributed to schoolchildren's parents in Gimhae in 2008. Responses were collected from 1,703 parents. The standard questionnaire of Ministry of Health and Welfare was used and items were socioeconomic variables, water used for drinking and cooking, awareness on the fluoridation program and approval on the expansion implementation of fluoridation program at the region of Myeongdong water plant. Significance was analyzed by chi-square test and multiple logistic analysis. Results: Of parents, 1.9% used plain tap water and 39.8% used boiled tap water for drinking and 50.0% used tap water for cooking. 58.0% of parents were aware of fluoridation program with 27.1% being aware of the implementation of the program in Gimhae. 74.5% approved the expansion implementation of the program to the region of Myeong-dong water plant. Significant variables associated to approving the expansion implementation of program were age, gender, residence period in Gimhae, occupation and awareness of the program. Conclusion: The expansion implementation of fluoridation program in Gimhae is desirable for caries prevention because of the majority of schoolchildren's parents' approval.

수도관 재질에 형성된 초기 생물막 형성 미생물의 군집 특성 (Community characteristics of early biofilms formed on water distribution pipe materials)

  • 김영관;박성구;이동훈;최성찬
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.767-777
    • /
    • 2012
  • Annular Biofilm Reactor (ABR) equipped with coupons of three different pipe materials (STS 304, PVC, PE) was used to generate drinking water biofilm samples. The level of assimilable organic carbon (AOC) during the sample generation period was $37.3{\mu}g/L$, and this level did not seem to be low enough to limit the formation of biofilm in this study. Terminal-restriction fragment length polymorphism (T-RFLP) analyses determined T-RF profile as early as 3 h of exposure on PVC coupons. Average surface roughness ($R_a$) measured by atomic force microscopic analyses was 125.7 nm for PVC, and this value was higher than for STS (71.6 nm) and PE (74.0 nm). However, biofilm formation was faster on STS (6 h) than on PE (12 h), which indicated that surface roughness might not be the only factor that controlled the initiation of biofilm development. Upon detection of the T-RF peaks, richness (S) and diversity indices such as Shannon (H) and Simpson (1/D) demonstrated a rather slow increase until 48 h followed by rapid increase regardless of the pipe materials. Differences of microbial community structures among the biofilm samples were determined based on the cluster analysis using Jaccard coefficients (Sj). Biofilm communities could be divided into two distinct groups according to the exposure time regardless of the pipe materials. First group contained a young (< 48 h) biofilm samples (10 out of 11) but second group contained a mature (${\geq}$ 48 h) samples (11 out of 14). Results suggested that, due to the complexity of biofilm, the targeting of the first group of cluster was crucial for optimizing the management of drinking water distribution systems and controlling microbial growth.

Epidemiologic Study on Hepatitis A Virus Seroprevalence in Busan

  • Cho, Kyung-Soon;Park, So-hyun
    • 대한임상검사과학회지
    • /
    • 제46권1호
    • /
    • pp.17-21
    • /
    • 2014
  • The prevalence of hepatitis A virus (HAV) in a certain community reflects that community's living standard and hygienic condition. The seroprevalence rate of IgG anti-HAV has been changing with regions and times. In this study, we aimed to study the difference of seroprevalence of IgG anti-HAV according to sex, age and type of drinking water, and to know the vaccination rate and seroconversion rate for vaccinated subjects in Busan. A total of 644 samples were analyzed. The overall seroprevalence rate of IgG anti-HAV was 35.4% (228/644). There was no significant difference in sex (male 39.8%, female 32.7) (p>0.05). According to age, seroprevalence rate of anti-HAV were 55.0% in subjects aged 5~9 years old, 47.8% in 10~14 years old, decreced to 10.6% in 15~19 years old, 1.0% in 20~24 years old, 0.0% in 25~29 years old and increced with advacing ages ; 14.7% in 30~34 years old, 39.4% in 35~39 years old, 67.3% in 40~44 years old, 94.1% in 45~49 years old, 100.0% over 50 years (p<0.001). The seroprevalence of IgG anti-HAV was no statistical difference according to the types of drinking water (p>0.05). The vaccinated subject was 42 case only in below 25 years old. The seroconversion rate after vaccination was 88.1%.

한 작은 섬에서의 파라콰트 집단중독 (Mass paraquat poisoning in a small island community (case report))

  • 이성우;정태화;최강원;임정기;이덕형
    • Journal of Preventive Medicine and Public Health
    • /
    • 제22권4호
    • /
    • pp.454-465
    • /
    • 1989
  • In a small island community with a population of less than 100 residents, nine persons died and five experienced severe illnesses during the period from November 1986 to May 1988. Their initial symptoms were sore throat and fever. Renal failure and hepatitis developed within one week after the onset. Oral mucosal ulcer developed in some cases. After one week, progressive respiratory failure and dyspnea developed evidently and severe respiratory distress and hypoxia preceded those fatal cases. Chest X-ray findings revealed bilateral diffuse multiple cystic lesion with occasional multiple large emphysematous bullae. Based on these features paraquat poisoning was diagnosed and route of poisoning was investigated. In three sources of drinking water, trace amount of paraquat was detected in November 1988, six months after the incidence of recent fatal case. In November 1988, soybean sauces and soybean pastes from 12 households were found contaminated with high concentration of paraquat, the cause could not be identified. The possibility of the contamination of drinking water as the cause of this mass poisoning has been suggested.

  • PDF

고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구 (Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.