• Title/Summary/Keyword: communication cable

Search Result 439, Processing Time 0.028 seconds

A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings (건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구)

  • Hong, Sung-Ho;Choi, Moon-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF

A study for the stability of international submarine cables within Korean waters (한국 연근해 국제해저광케이블 안정성을 위한 연구)

  • Lee, Young-Sun;Jung, Jae-Jin;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2007
  • Submarine cable is the leading means of international communication across oceans. However, when such important submarine cable is damaged, that causes not only huge amount for the repair but also losing the nation's reliability internationally, and has brought about much difficulty and loss due to the interruption of communication. So, in order to deduce methods for the stability of submarine cables, this paper is studying the present status of submarine cables and the causes of cable faults, and suggesting techniques and regulations to protect from the trouble of submarine cables.

  • PDF

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.

Efficient Test Techniques for Submarine Cable Repair (해저광케이블 수리를 위한 효율적인 탐지 및 측정 기법)

  • Lee, Young-Sun;Jung, Jae-Jin;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Submarine cable is the most important IT infrastructure for international communication across oceans. However, a cable fault rarely happens by ship's anchor, fishing gears, submarine earthquake, and so on, and we need to improve on repair time for the reducing expenses of cable repair ship as well as the stability of high-capacity submarine optical network. There are several kinds of cable faults such as Shunt fault, Cable cut, Open fault and Fiber break. When a fault is occurred, cable landing stations(CLS) have to analysis failure quickly and accurately to find the type and the location of a cable fault. During the repair period, CLS should swiftly perform the tests requested by cable repair ship. In order to make rapid progress on cable repair, CLS test technique is very important. So, in order to reduce the repair time, this paper is studying the CLS test techniques of locating a submarine cable fault and of checking the splicing point performed by cable repair ship.

  • PDF

A study on the moving picture transmission method by railway fiber optics cable (철도 광케이블을 이용한 화상전송방안에 관한 연구)

  • Cho B. K.;Chang S. G.;Ryu S. H.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.468-473
    • /
    • 2003
  • CCTV network has been implemented to transmit the image information of platfo gate and transfer section to local headquarters in the KNR(Korean National Railroa But. communication system for transferring image information around accident field has not been established yet. thus, at present implementation of communication equipment is necessary for dyn of unspecified accident to be transmitted to headquarters. Copper cable communication network is run by KNR, but it is processing installatio optics cable in connection with the implemental plan for high-speed network from n And, the capacity of communication channel will be guaranteed much more than een station and station, station and central headquarters when fiber optics cable is This study analyzes the image equipment of field for transmission and estimated m transmit image information of accident field to headquarters with using communicat ucture. And, the study considers implemental method of communication network for nce image transmission from dozens to hundreds kilometers.

  • PDF

Development of Stainless Steel Loose Tube Optical Ground Wire with 144 Single Mode Fibers (144심용 초다심 SSLT OPGW 개발)

  • Baik, S.Y.;Kim, K.M.;Kim, S.W.;Kim, D.W.;Lee, I.H.;Sohn, K.I.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.395-398
    • /
    • 2001
  • Recently, the increasing need for internet and the activation of hiring business of communication line makes the demand for OPGW cable which can construct the optical communication network in the basis of existing overhead power transmission line. Especially, the demand is focused on the high fiber count OPGW due to high capacity transmission. In step with the trend toward high fiber count cable we have developed the Stainless Steel Loose Tube type OPGW within which have 144core firstly in KOREA. This paper describes the cable design and manufacturing process which gives the stable operation in very severe conditions and the long-term reliability test results conducted in according to dominant specification IEEE Std. 1138-1194.

  • PDF

Cable Identification Technology based on Power Line Communication (전력선 통신을 활용한 케이블 식별 기술)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.880-883
    • /
    • 2015
  • Power-line communication technology is proposed to identify cables of power distribution systems. It can extend the application area of power-line communication. Distribution line cable circuits have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the cable. A novel power cable identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts. Also some simulations are done to help and understand the concepts by using Simulink simulator.

  • PDF

A study for construction of Shore-end Submarine cable (천해부에서 해저케이블 건설 연구)

  • Jung, Jae-Jin;Lee, Young-Sun;Shin, Hyun-Shik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.3
    • /
    • pp.185-190
    • /
    • 2007
  • The biggest cause of submarine cable fault is fishing activity such as 70% by anchor of fishing boats and occurs within 200m the depth of water. It needs a regulation for protection of submarine cable from the fishing boats and construction of cable at shore-end. This paper is studying a plan and regulation to install the construction among the subsee users, and the burial technique of submarine cable at shore-end suggests to manage from company to government.

  • PDF

Analyses of the submarine cable faults of EAC and Protection Ways (동아시아횡단 해저케이블 고장분석을 통한 보호방안)

  • Yoo, Jae-Duck;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.227-232
    • /
    • 2010
  • Submarine cable system has been affected by humankind activities like trawl and stow net which has been threatening submarine cable in Korea. This research presents the protection ways of submarine cable through the analyses of cable faults on EAC system for 8 years.