• Title/Summary/Keyword: common arm

Search Result 207, Processing Time 0.025 seconds

Closed Manual Reduction of Mandibular Condylar Fracture Assisted by C-arm Fluoroscopy (C-arm 형광투시를 이용한 하악관절돌기골절의 비관혈적 도수정복)

  • Choi, Eui Chul;Kang, Sang Gue;Jung, Sung Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.131-134
    • /
    • 2009
  • Purpose: Mandible fractures are common in maxillofacial trauma and the incidence of condylar fracture is high. The management of mandibular condylar fracture continues to be controversial. Conservative treatment of it may lead to complications such as asymmetry, malocclusion, temporomandibular joint dysfunction. Moreover, open reduction can cause facial nerve injury, parotid gland injury, scarring and hematoma formation. We present a case of mandibular condylar fracture that was treated by manual reduction without incision under C-arm fluoroscopy. Methods: A 76-year-old female was admitted due to left side mandibular condylar fracture that required surgical intervention. Because of her age, history of diabetes mellitus, hypertension, she underwent closed manual reduction under general anesthesia. We adopted C-arm fluoroscopy as a method of identifying the fracture site and a evaluation of reduction state. C-arm fluoroscopy was set up like modified Towne's view. Results: The reduction was successful and didn't result in any complications that could occur in open reduction-facial nerve injury, infection, parotid gland injury, hematoma, avascular necrosis. The mandibular-maxillary fixations were removed after 4 weeks and patients were could open 3.5 cm after 6 weeks with physical therapy. Conclusion: We tried closed manual reduction of mandibular condylar fracture due to high risk of complication using C-arm fluoroscopy and did achieve anatomic reduction with avoiding open incision. This is simple, effective, reversible, time saving and fairly attemptable method in condylar fracture cases before open reduction.

ARM: Anticipated Route Maintenance Scheme in Location-Aided Mobile Ad Hoc Networks

  • Park Seungjin;Yoo Seong-Moo;Al-Shurman Mohammad;VanVoorst Brian;Jo Chang-Hyun
    • Journal of Communications and Networks
    • /
    • v.7 no.3
    • /
    • pp.325-336
    • /
    • 2005
  • Mobile ad hoc networks (MANET) are composed of moving wireless hosts which, within range of each other, form wireless networks. For communication to occur between hosts that are not within each other's range, routes involving intermediate nodes must be established; however, since the hosts may be in motion, a host that was part of a route may move away from its upstream and downstream partners, thus breaking the route. In this paper, we propose anticipated route maintenance (ARM) protocol with two extensions to route discovery based routing scheme: Extend the route when nodes on a link move apart from each other and they have common neighbor that can be 'inserted' in the path, and shrink route when a node discovers that one of its neighbor which is not the next hop is also on the same route several hops later on. By utilizing only local geographic information (now a part of some route finding algorithms), a host can anticipate its neighbor's departure and, if other hosts are available, choose a host to bridge the gap, keeping the path connected. We present a distributed algorithm that anticipates route failure and performs preventative route maintenance using location information to increase a route lifespan. The benefits are that this reduces the need to find new routes (which is very expensive) and prevents interruptions in service. As the density of nodes increases, the chance to successfully utilize our route maintenance approach increases, and so does the savings. We have compared the performance of two protocols, pure dynamic source routing (DSR) protocol and DSR with ARM. The simulation results show how ARM improves the functionality of DSR by preventing the links in the route from breaking. Packets delivery ratio could be increased using ARM and achieved approximately $\100%$ improvement. The simulations clarify also how ARM shows a noticeable improvement in dropped packets and links stability over DSR, even though there is more traffic and channel overhead in ARM.

Removal of Broken Instruments in Soft Tissue at Mandibular Area Using a Dental Mini C-arm: Case Reports (치과용 소형 C자형 투시장치를 이용한 하악 연조직에 위치한 부러진 기구의 제거: 증례보고)

  • Park, Sung-Soo;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 2010
  • Intraoperative breakage of instruments can be occurred unexpectedly. To prevent damage of neighboring important anatomic structures and consequent complications, broken instruments should be removed as soon as possible. There have been several methods to remove broken instruments. One of them is the Carm fluoroscopy which is commonly used for locating metal foreign bodies. However, its application for removal of broken instruments in the oral and maxillofacial area is not common. In our experiences with the removal of two broken instruments in mandibular area, the newly developed dental mini C-arm was used to find broken instrument in soft tissue, because it gives real-time in situ information for the intraoperative location. We report two cases with broken instruments, a broken dental needle in the pterygomandibular space and a broken straight bur in the mandibular angle area. They were identified and could be removed safely using a dental mini C-arm.

Design of Mobile Telemedicine System using RFID based on Embedded Linux (임베디드 리눅스 환경에서 RFID 기반의 Mobile Telemedicine System 구현)

  • Yun, Chan-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.479-482
    • /
    • 2006
  • Mobile Telemedicine uses common technologies that provide a conduit for information exchange between physicians nurses and patients. In addition to patient records, medical professionals will obtain vital signs and other reference data through Ubiquitous Sensor networks(USN). In this paper about a design and implementation of RFID reader platform that received RFID tag information from patients tags, transmit the data to SBC(Single board computer) based on Intel PXA255 ARM CPU and SBC transmit the data to MySQL server in hospital using by Wireless Internet. his system that based on Embedded Linux is composed of RFID module, ARM processor, RS-232 interface, and Wireless LAN. This paper also provides a brief overview and concept of RFID reader, and proposes the design and implementations of the RFID reader platform used QT and MySQL based on Embedded Linux.

  • PDF

A New Simplified Vector Control For A High Performance Common-Arm IHCML Inverter (고성능 공통암 IHCML 인버터를 위한 새로운 벡터 제어 방식)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1071-1079
    • /
    • 2007
  • In this paper, a novel space vector control method for isolated multi-level inverter using 3-phase low frequency transformers is proposed. This method is based on the simplification of the space-vector diagram of a five-level inverter using calculated table into fully programming method. The execution time of the proposed method is about same as that of the method using calculated table. Also, the proposed method is easily applied to other case level inverter. We applied this method into the 3-phase IHCML inverter using common arm. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformers could be reduced compare with an exiting 3-phase multi-level inverter using single phase transformer. In addition, this method generates very low harmonic distortion operation with nearly fundamental switching frequency. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

Effects of Nutrition Education on Nutritional Status of Hemodialysis Patients (영양교육이 혈액투석환자의 영양상태에 미치는 효과)

  • 양정례;서혜정;김양하
    • Journal of Nutrition and Health
    • /
    • v.36 no.7
    • /
    • pp.749-758
    • /
    • 2003
  • Malnutrition is a common problem in patients undergoing maintenance hemodialysis (HD) and compromised food intake is an important cause. Malnutrition is one of the important factors influencing mortality in these patients. This study was conducted to evaluate the effectiveness of nutrition education at improving nutritional status of 23 Korean HD patients (mean : 48.6 $\pm$ 10.4 years, men : 8, women : 15). Anthropometric indices, nutrient intakes, and biochemical blood indices were measured before and after a 6-month nutrition education intervention. Anthropometric indices such as percent ideal body weight [PIBW (%)], body fat, body mass index (BMI), mid-arm circumference (MAC), mid-arm muscle circumference (MAMC), and calculated arm muscle area (CAMA) of subjects were within the normal range and not changed by nutrition education. Subjective global assessment (SGA) was significantly increased (p < 0.05) after nutrition education. Intake of total energy, carbohydrate, lipid, Ca, and vitamin B1 was increased significantly (p < 0.05) but intake of phosphorus, potassium, and sodium was decreased (p < 0.05). The serum concentrations of albumin, total protein, and Ca were significantly increased (p < 0.05), but levels of P and K were decreased (p < 0.05) after the intervention. These findings suggest that nutrition education for HD patients can be effective for positively changing nutrient intakes, leading to improvements in blood indices and nutritional status.

Robotic Peg-in-Hole Assembly by Hand Arm Coordination (손과 팔의 협업에 의한 로봇 펙인홀 작업)

  • Park, Hyeonjun;Kim, Peter Ki;Park, Jaeheung;Jang, Ja-Ram;Shin, Yong-Deuk;Bae, Ji-Hun;Park, Jae-Han;Baeg, Moon-Hong
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • Peg-in-hole assembly is the most representative task for a robot to perform under contact conditions. Various strategies for accomplishing the peg-in-hole task with a robot exist, but the existing strategies are not sufficiently practical to be used for various assembly tasks in a human environment because they require additional sensors or exclusive tools. In this paper, the peg-in-hole assembly experiment is performed with anthropomorphic hand arm robot without extra sensors or devices using "intuitive peg-in-hole strategy". From this work, the probability of applying the peg-in-hole strategy to a common assembly task is verified.

A Study on Visual Feedback Control of a Dual Arm Robot with Eight Joints

  • Lee, Woo-Song;Kim, Hong-Rae;Kim, Young-Tae;Jung, Dong-Yean;Han, Sung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.610-615
    • /
    • 2005
  • Visual servoing is the fusion of results from many elemental areas including high-speed image processing, kinematics, dynamics, control theory, and real-time computing. It has much in common with research into active vision and structure from motion, but is quite different from the often described use of vision in hierarchical task-level robot control systems. We present a new approach to visual feedback control using image-based visual servoing with the stereo vision in this paper. In order to control the position and orientation of a robot with respect to an object, a new technique is proposed using a binocular stereo vision. The stereo vision enables us to calculate an exact image Jacobian not only at around a desired location but also at the other locations. The suggested technique can guide a robot manipulator to the desired location without giving such priori knowledge as the relative distance to the desired location or the model of an object even if the initial positioning error is large. This paper describes a model of stereo vision and how to generate feedback commands. The performance of the proposed visual servoing system is illustrated by the simulation and experimental results and compared with the case of conventional method for dual-arm robot made in Samsung Electronics Co., Ltd.

  • PDF

Kimura's Disease in the Arm - A Case Report - (상지에 발생한 기무라씨병 - 증례 보고 -)

  • Kim, Ju-O;Hur, Hae-Ryong;Yoo, Sang-Moon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 2001
  • Kimura's disease is a mass producing uncommon chronic inflammatory process of unknown cause. It is more common among Orientals and affects particularly the young male. Sites of predilection include the head and neck regions, primarily the subcutaneous tissue and dermis. It's clinical course is benign in nature. The treatment modalities for this disease are surgical excision, steroid therapy and radiation therapy. We experienced a case of soft tissue mass in the right upper arm. It was painless and relatively movable. We performed marginal excision of the mass, which was turned out to be Kimura's disease on microscopic examination. In this case, disease recurrence was not found fifteen months after the operation.

  • PDF

Removal of Esophageal Submucosal Foreign Body Under C-arm Fluoroscopic Guidance (C-arm 방사선 투영법을 이용한 식도 점막 하 이물 제거)

  • Kim, Heejin;Kim, Hyo-Sang;Cha, Wonjae;Sung, Myung-Whun;Hah, J. Hun
    • Korean Journal of Bronchoesophagology
    • /
    • v.19 no.1
    • /
    • pp.15-18
    • /
    • 2013
  • Esophageal foreign body is common condition for visit emergency room, and most of them were successfully removed with endoscopy. However, in case of esophageal foreign body impaction, it can be difficult to localize the foreign body. We report a 29-year old man with esophageal foreign body impaction. We successfully localized and removed the esophageal submucosal foreign body using rigid endoscopy under C-arm guidance, avoiding more invasive procedure. The patient was followed up without any complication.

  • PDF