• Title/Summary/Keyword: commercial power

Search Result 2,023, Processing Time 0.029 seconds

The Removal of Surfactants and Commercial Detergents by Oenanthe javanica (미나리를 이용한 계면활성성분 및 합성세제 제거에 관한 연구)

  • 김경민;최한영;신정식;나규환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.115-120
    • /
    • 1997
  • The purpose of thesis was to investigate the removal efficiency of surfactants and commercial detergents by Oenanthe javanica that is one of aquatic plants in Korea. The experiment is concerned with measuring the concentrations of surfactants and commercial detergents in different media: 1) in pure water, 2) in water containing Oenanthe javanica, 3) in water containing Oenanthe javanica and commercial nutrients. The surfactants used in this research include linear alkylbenzene sulfonates (LAS), $\alpha$-sulfo fatty acid methyl esters(MES), and alkylbenzene sulfonates(ABS). Two commercial detergents designated as A and B were in the forms of power and liquid. The results showed that LAS and MES were more effectively removed by Oenanthe javanica probably because these have a chain of linear carbon than on ABS with a branched carbon structure. In the case of commercial detergents, when the except was performed on the basis of surfactants proportion, the removal trends were similar to LAS and MES. The 5-day cultivating test with initial concentration of 0.5-1.0 ppm surfactants showed that less than 10% was removed if no nutrients an Oenanthe javanica were added. When Oenanthe javanica was added into the sample solution containing surfactants, the removal efficiency was increased 100% for the solution containing 0.5-1.0 ppm 60-70% for 5-10 ppm. In addition, chlorisis on Oenanthe javanica was observed due to surfactants and commercial detergents for all three cases. To test the dependence of population density on nutrients, the initial population density was made 300 g/0.4 m$^2$. Throughout the 5-day experiment, the on Oenanthe javanica grew 20-25% with 0.5-1.0 ppm without the synthetic nutrients but by 5% with a high concentrations of 5-10 ppm. The population density was appeared to be independent of synthetic nutrients. The leaves were to be grown with synthetic nutrients, while roots were grown without synthetic nutrients. Based on this research, the fundamental data concerning cultivation and an adequate adjustment of the water condition can provide for the utilization of Oenanthe javanica in real water treatment system.

  • PDF

Wireless Power Transfer via Magnetic Resonance Coupling (MRC) with Reduced Standby Power Consumption

  • Lee, Byoung-Hee
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.637-644
    • /
    • 2019
  • Wireless power transfer (WPT) technology with various transfer mechanisms such as inductive coupling, magnetic resonance and capacitive coupling is being widely researched. Until now, power transfer efficiency (PTE) and power transfer capability (PTC) have been the primary concerns for designing and developing WPT systems. Therefore, a lot of studies have been documented to improve PTE and PTC. However, power consumption in the standby mode, also defined as the no-load mode, has been rarely studied. Recently, since the number of WPT products has been gradually increasing, it is necessary to develop techniques for reducing the standby power consumption of WPT systems. This paper investigates the standby power consumption of commercial WPT products. Moreover, a standby power reduction technique for WPT systems via magnetic resonance coupling (MRC) with a parallel resonance type resonator is proposed. To achieve a further standby power reduction, the voltage control of an AC/DC travel adapter is also adopted. The operational principles and characteristics are described and verified with simulation and experimental results. The proposed method greatly reduces the standby power consumption of a WPT system via MRC from 2.03 W to 0.19 W.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Experimental Waveforms of Single-Pulse Soft-Switching PFC Converter

  • Katsunori Taniguchi;Koh, Kang-Hoon;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.56-63
    • /
    • 2004
  • A new driving circuit for the SPSS (Single-Pulse Soft-Switching) PFC converter is proposed. The switching device of a SPSS converter switches once in every half cycle of an AC commercial power source. Therefore, it can be solved many problems caused by the high frequency operation. The proposed SPSS converter achieves the soft-switching operation and the EMI noise can be reduced. The resonant capacitor voltage supplies to the resonant inductor even if the input AC voltage is the vicinity of zero cross voltage. Then, the power factor and input current waveform can be improved without delay time. A new driving circuit achieves the operation of SPSS converter by one switching drive circuit. The proposed converter can be satisfied the IEC standard sufficiently

High-Performance Metal-Substrate Power Module for Electrical Applications

  • Kim, Jongdae;Oh, Jimin;Yang, Yilsuk
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.645-653
    • /
    • 2016
  • This paper demonstrates the performance of a metal-substrate power module with multiple fabricated chips for a high current electrical application, and evaluates the proposed module using a 1.5-kW sinusoidal brushless direct current (BLDC) motor. Specifically, the power module has a hybrid structure employing a single-layer heat-sink extensible metal board (Al board). A fabricated motor driver IC and trench gate DMOSFET (TDMOSFET) are implemented on the Al board, and the proper heat-sink size was designed under the operating conditions. The fabricated motor driver IC mainly operates as a speed controller under various load conditions, and as a multi-phase gate driver using an N-ch silicon MOSFET high-side drive scheme. A fabricated power TDMOSFET is also included in the fabricated power module for three-phase inverter operation. Using this proposed module, a BLDC motor is operated and evaluated under various pulse load tests, and our module is compared with a commercial MOSFET module in terms of the system efficiency and input current.

Performance Analysis of Supercritical Coal Fired Power Plant Using gCCS Simulator

  • Tumsa, Tefera Zelalem;Mun, Tae-Young;Lee, Uendo;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.37-40
    • /
    • 2014
  • Capturing the carbon dioxide emitted from coal-fired power plants will be necessary if targeted reduction in carbon emissions is to be achieved. Modelling and simulation are the base for optimal operation and control in thermal power plant and also play an important role in energy savings. This study aims to analyze the performance of supercritical coal fired power plant through steady and dynamic simulation using a commercial software gCCS. A whole power plant has been modeled and validated with design data of 500 MWe power plant, base and part load operations of the plant were also evaluated, consequently it had been proven that the simulated result had a good agreement with actual operating data. In addition, the effect of co-firng on the plant efficiency and flue gases were investigated using gCCS simulator.

  • PDF

A Study on AC/DC Converter Design of High Efficiency for Inverter Resistance Welder (인버터 저항용접기의 전력효율 향상을 위한 AC/DC 컨버터 설계에 관한 연구)

  • Kwak, D.K.;Jung, W.S.;Kang, W.C.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.40-41
    • /
    • 2016
  • The inverter resistance welder requires AC/DC converter of high efficiency because the converter changes a commercial ac power source to low voltage dc power source. Harmonic components that occur in the conversion process of converter decrease system power factor and deal great damage in electric power system. To improve such problems, this paper proposes a high efficiency AC/DC converter for inverter resistance welder. The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit. As a result, the proposed AC/DC converter obtains low switching power loss and high efficiency.

  • PDF

Design Considerations for Auto-Connected Multi-Pulse Rectiviers for High Power AC Motor Drives

  • ;Prasad N. Enjeti
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.413-422
    • /
    • 1999
  • Auto-connected multipulse(12/24pulse) rectifier schemes are cost effective methods for reducing line current hamonics in PWM drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations In particular, excursion of dc-link voltage at no load, effect of pre-existing voltage distortion, impedance mismatches, unequal diode drops on rectifier current sharing and performance, are fully analyzed, Several corrective measures to improve the performance of 12/24­pulse rectifier systems are also discussed. Finally, experimental results on a 460V, 60Hz 400kVA commercial ASD, retrofitted with 12/24pulse rectifier systems are discussed in detail.

  • PDF

A Study on the characteristics and Development of Power supply for ozonizer (오존 발생기용 전원 장치 개발 및 특성에 관한 연구)

  • Kim, Jong-Hae;Bae, Sang-June;Lee, Young-Sik;Jo, Gee-Yeun;Jeong, Seung-Kyun;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2069-2071
    • /
    • 1997
  • The power semiconductor switching devices(PSSD) continuously developed, Power Electronic Technology using PSSD is gradually extended. The high frequency inverter to generate the large power high frequency subject to power electronic technology pursuit various application. Also, in emboss with environmental destruction problem cause the atmosphere and the water pollution to growth of the commercial society, the research in favor of cleansing environmental a pollutant actively proceed. This paper describe study on the ozone generation power supply using the high frequency electric field method and the lamp type ozone generator using photochemistry, one of method of gene-rate ozone.

  • PDF

Residential Solar Cell System by driving of High Efficiency Inverter

  • Kwak Dong-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.687-691
    • /
    • 2001
  • With today's global environmental and energy problems, high expectations exist for solar power generation to reduce carbon dioxide generated by the consumption of fossil fuels. On the other hand, power consumption in residential homes is increasing every year. Among the many household appliances, the power demand for air conditioners increases dramatically during the summer, particularly in the afternoons. As this pattern closely matches the output pattern of solar cells, it should be possible to combine a photovoltaic array with an air conditioner to decrease the energy consumption within the home. We have developed a residential solar-powered air conditioner that operates through a combination of photovoltaic array and commercial power. In this paper, the configuration and specification of the residential solar-powered system are described to a novel high efficiency inverter using a ZVCS boost converter. And the performance evaluations of the solar-powered air conditioner are examined by the analysis of a new tracking controller with a maximum power $P_{max}$ detection of solar cell.

  • PDF