• Title/Summary/Keyword: commercial computer code

Search Result 101, Processing Time 0.065 seconds

FEASIBILITY OF AN INTEGRATED STEAM GENERATOR SYSTEM IN A SODIUM-COOLED FAST REACTOR SUBJECTED TO ELEVATED TEMPERATURE SERVICES

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1115-1126
    • /
    • 2009
  • As one of the ways to enhance the economical features in sodium-cooled fast reactor development, the concept of an integrated steam generator and pump system (ISGPS) is proposed from a structural point of view. And the related intermediate heat transfer system (IHTS) piping layout compatible with the ISGPS is described in detail. To assure the creep design lifetime of 60 years, the structural integrity is investigated through high temperature structural evaluation procedures by the SIE ASME-NH computer code, which implements the ASME-NH design rules. From the results of this study, it is found that the proposed ISGPS concept is feasible and applicable to a commercial SFR design.

Finite Element Analysis of Two Rectangular Plates Coupled with Fluid (유체와 연성된 두 직사각형 평판의 유한요소 해석)

  • 유계형;정경훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.668-671
    • /
    • 1997
  • In order to investigate the vibration characteristics of fluid-structure interaction problem, we modeled two identical rectangular plates coupled with bounded fluid. The fixed boundary condition along the plate edges and an ideal fluid were assumed. A commercial computer code, ANSYS was used to perform finite element analysis and FEM solutions were compared with the experimental results to modify the finite element model. As a result, comparison of FEM and experiment showed good agreement, and the transverse vibration modes, in-phase and out of-phase. were observed alternately in the tluid-coupled system. The effects of distance between two rectangular plates and width to length ratio on the fluid-coupled natural frequency were investigated. And it was found that the ormalized natural frequency of the fluid-coupled system monotonically increased with an increase in the number of modes.

  • PDF

Design and Structure Improvement of Ultra Low Volume Sprinkler (초미립자 살포기의 설계 및 구조개선)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • In this paper, structural analysis was conducted by designing a ultra low volume sprinkler applied to spray liquid and applying a ANSYS commercial code for three dimensional finite element method to the ultra low volume sprinkler. Based on this numerical structural analysis, stress, strain and total deformation were obtained and the structure improvement of the ultra low volume sprinkler was made along with improved productivity and shorten design period.

Validation of a CFD model for hydraulic seals

  • Roy, Vincent Le;Guibault, Francois;Vu, Thi C.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.400-408
    • /
    • 2009
  • Optimization of seal geometries can reduce significantly the energetic losses in a hydraulic seal [1], especially for high head runner turbine. In the optimization process, a reliable prediction of the losses is needed and CFD is often used. This paper presents numerical experiments to determine an adequate CFD model for straight, labyrinth and stepped hydraulic seals used in Francis runners. The computation is performed with a finite volume commercial CFD code with a RANS low Reynolds turbulence model. As numerical computations in small radial clearances of hydraulic seals are not often encountered in the literature, the numerical results are validated with experimental data on straight seals and labyrinth seals. As the validation is satisfactory enough, geometrical optimization of hydraulic seals using CFD will be studied in future works.

Development of 5-axis $CO_2$ Laser Cutting Machine and CAM (5축 CO2 레이저 컷팅 머신 및 CAM 시스템 개발)

  • Kang Jae-Gwan;Yeom S.B.;Kang B.S.;Lee H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.245-246
    • /
    • 2006
  • For developing 5-axis laser cutting systems, many problems such as rotating of laser head or table, 5-axis tool path generation and collision avoidance between laser head and product should be solved. In this paper, a five-axis laser cutting machine with table swivel and rotary type configuration is developed. The five axes (X,Y,Z,A,B) are controlled and interfaced to PC via MMC board. Two kinds of CAM S/W such as commercial 5-axis CAM S/W(Euclid) and UG-API are engaged to generate NC code for the developed 5-axis laser cutting machine.

  • PDF

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

Characteristics of the Transient Pressure in a Building Water Supply System with an Air Chamber (공기실이 설치된 건축물 급수관로의 과도압력 특성)

  • 황희성;임기원;이광복;조병선;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.782-790
    • /
    • 2000
  • A numerical study has been conducted to characterize the transient pressure in a building water supply system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for the purpose of verification in the study agree quite well with the previously reported. Several parameters are then varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the inner diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^P{circ}C $,/TEX> and 0.8 m/s, respectively, Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

A Study on flow Balance and Warpage Characteristics in Manufacturing of Plastic Injection Family Mould (Family 금형 제작에서의 유동 밸런스 및 휨특성에 관한 연구)

  • Kim K. H.;Song D. J.;Kwon C. O.;Lee S. H.;Heo Y. M.;Kim M. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.141-146
    • /
    • 2005
  • In the present study, the characteristic of warpage and flow balance for family mould, which is able to mold parts with different shapes in a mold, is considered. To obtain an optimal gate and runner system, plastic injection molding analysis with commercial code is performed. Design and manufacturing of family mould is then carried out on the basis of this computer aided engineering result. Flow balance and warpage comparisons between experiment and numerical analysis give good agreement with each other. However, it was shown that results of warpage measured by CMM was about $20\~55\%$ lower than those of numerical analysis.

  • PDF

Dynamic Characteristics of Water Hammer Arresters for Building Service Applications

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.1
    • /
    • pp.40-49
    • /
    • 2003
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial code that employs the method of characteristics. Some preliminary results with those arrester models produced in this study agree well with the previously reported. Then, the arrester models have been incorporated into a water supply pipe system of a 59 $m^2$apartment unit constructed by a leading construction company, and their dynamic characteristics have been investigated, especially on the reduction in the water hammer pressure. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure down below 1,082.0 kPa (10.0 kg$g_f$/$cm^2$) when quick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa (4.5 kg$g_f$/$cm^2$). More arresters in the system may be required to meet pressure criteria stated on the related standards and codes.

Shape Optimization of Structural Members Based on Isogeometry Concept (등기하 개념에 기초한 구조부재의 형상 최적화)

  • Lee, Joo-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.61-67
    • /
    • 2011
  • This study is concerned with the shape optimization of structural members frequently found in critical area in a structure system, that is, highly stressed zone. Isogeometry analysis is well known to be the very efficient way to integrate the geometric modeling(CAD) and computational analysis(CAE). This can be accomplished by directly using the geometric modeling by NURBS(Non-Uniform Rational Basis Spline). In this study, an efficient computer code adopting the isogeometry concept has been developed for the structural analysis, in which CAD information can be directly used in the finite element modeling. In order to show the validity of the present code, the present results are compared with those by using the commercial package, that is, MSC/NASTRAN. The present isogeometric analysis procedure has been integrated with the optimization procedure to deal with the optimization problem found in the context of structural mechanics. The present system has been successfully applied to the shape optimization of cantilever structure having bracket. From the present study, it can be seen the validity of the present approach and computer codes developed in this study. This paper ends with some discussions about the practical usefulness of the present approach which is based on isogeometry analysis, and extension of the present study.