• Title/Summary/Keyword: combustible

Search Result 514, Processing Time 0.028 seconds

Detecting Characteristics of Catalytic Combustible Gas Sensor (접촉연소식 가스 센서의 검지특성)

  • 박찬원;원창섭;유영한;안형근;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

A Suggestion on the Fire load and Combustible survey for Prediction of Fire in office Facilities (업무시설의 화재성상예측을 위한 가연물 조사 및 화재하중 제안)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.98-99
    • /
    • 2019
  • In Korea, buildings are becoming skyscrapers due to restrictions on land. The performance-oriented design was introduced in 2009 for fire safety of such buildings, but the application of the combustible data through engineering design and experiment is a poor reality. Large buildings are used for complex purposes, especially since the density of the office facilities is high, the study conducted a study on the combustible materials of the office facilities and the thermal speed and fire load of the main combustibles of the office facilities were calculated.

  • PDF

The Relationship between Flash Point and Fire Properties of Flammable Liquids (가연성 액체의 인화점과 화재특성치와의 관계)

  • Song, Young-Ho;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.10-14
    • /
    • 2007
  • Flash point is one of the major physical properties used to evaluate fire hazards of the combustible liquids. Properties showing relative fire hazards of the combustible liquids are heat release rate(HRR), peak heat release rate(PHRR), time to ignition(TTI), mass loss rate, and yield of $CO/CO_2$. The relationships between flash points and fire properties of the combustible liquids were examined in this study. For this study, mass loss rate and time to ignition were measured to calculate fire properties of the combustible liquids. The results showed that good correlations could be found between flash point and time to ignition, time to peak heat release rate, and the propensity to flashover. From a presented results, the parameters can be used to evaluate relative hazards of the combustible liquids on fire.

  • PDF

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

The external benefit of combustible waste-to-energy: A contingent valuation study (가연성 폐기물 에너지화의 외부편익 : 조건부 가치측정법의 적용)

  • Lim, Seul-Ye;Kim, Ho-Young;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.270-282
    • /
    • 2013
  • Combustible waste into energy policy is an effective method to respond to climate change and depletion of fossil fuels. Combustible waste into energy is the process of generating energy in the form of electricity and/or heat from the combustible waste such as vinyl, paper and plastic. This study tries to estimate the external benefit of enhancing the ratio of combustible waste into energy to primary energy from 1.89% to 5% using contingent valuation(CV) method. To this end, we report the results from a CV survey to elicit the willingness to pay (WTP) for combustible waste into energy. A CV survey of 500 households was conducted in the Seoul by using person-to-person interviews. Thus, the procedures of applying and the findings from the one-and-one-half bounded dichotomous choice spike model used to deal with the zero WTP responses are provided in the paper. The results show that the average WTP is estimated to be 2,724 won per household per month and statistically significant at the 5% level. Expanding the value to the Seoul gives us an aggregate value of 13.7 billion won per year.

Index Evaluation to Define the Bioenergy as a Renewable Energy Resource (바이오에너지를 정의하는 지표들에 대한 고찰)

  • Soh, Jin-Young;Kim, Hyun-Jong;Lee, Jae-Sung;Oh, Kyeong-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.480-487
    • /
    • 2013
  • Bioenergy is classified to one of the renewable energy resources such as solar, wind, hydro and tidal energies. It should be noted that all the renewable energies contribute to the reduction of greenhouse gases emission. In some cases, energy from wastes was also categorized as a renewable energy in our country even though it has only negligible effect on the emission reduction. In this paper, we tried to identify the bioenergy in order to follow the global indices of the renewable energy. The indices evaluated here were whether a resource is renewable, biogenic, biodegradable, combustible and organic. Biogenic and combustible were selected as the indices to identify the bioenergy. It was also suggested that combustible as an index can be exchangeable to organic.

Physicochemical Properties of Landfill Mined Wastes from Old Landfill Site (불량 매립지에서 굴착된 폐기물의 물리화학적 특성평가)

  • 남궁완;이노섭;박준석;인병훈
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.99-108
    • /
    • 2002
  • This study was carried out to evaluate the Physicochemical characteristics of mined waste(separated waste and soil) and to predict environmental effect of an old landfill site located at north of Seoul. Municipal solid waster(MSW) had been disposed of at the old landfill site used in this study for about 2 years(1990-1992). The old landfill site selected for this study had accepted mainly municipal solid waste. The landfill-mined waste contained separated waste (40.9%) and soil(59.1%) by wet weight basis. The separated waste consisted of combustible(91.0%) and non-combustible(9.0%). The combustible waste was mainly non-biodegradable plastics. The low heating value of the separated combustible waste, which is calculated by Dulong's equation, was as high as 3,470kcal/kg. According to the Korean Extraction Procedure, separated waste and soil were proved to be not hazardous. The total content of heavy metal in the separated waste and soil met standard of California State, USA. Therefore the separated waste may be relandfilled at a sanitary landfill site and/or burned up at an incinerator, and the separated old soil may be used ad landfill cover-soil at a sanitary landfill site. Water quality of two streams was grade IV, of which water could be used as industrial and agricultural water. The streams near the landfill site might not be contaminated by leachate from the old landfill site. It was estimated that organic matter in the old landfill site would not be actively biodegraded within a short period of time.

Analysis of the Emission Potential of Hazardous Pollutants Produced from disposal of the School Solid Wastes by Small-Scale Incinerator (학교 생활 쓰레기의 성분 분석과 소형소각로 운전에 따른 유해성 오염물의 배출 잠재성 분석 연구)

  • 이병규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.299-308
    • /
    • 2000
  • This study analyzed solid wastes generated from a school. The emission potential of hazardous pollutants generated from incineration of the school solid wastes (SSWs) was analyzed. Components of the SSWs were identified and the SSWs were classified into combustible and non-combustible wasts. The combustible wastes consisted of papers of 56.5^ plastics of 30.2% woods of 7.1% and fibers of 6.1% based on weight of the wastes. The moisture content and the ash content of the combustible wastes were 18~20% and 11~13% respectively. The combustible wastes of the SSWs were incinerated by using a small-scale incinerator. Fly and bottom ashes and volatile organic compounds (VOCs) were collected from the incineration. Also the metal leaching experiments on the fly and bottom ashes were performed, In analysis of metals leached from the ashes the total amounts of metals leached in the acid solution (pH=3) were much greater than those in the neutral solution (pH=5.8~6.2) For the same amounts of the fly and bottom ashes the total amounts of metals leached from the fly ashes were much greater than those from the bottom ashes. The VOCs produced from incineration of the SSWs consisted of aromatics of 42.1% aliphatic alkenes of 26.3% oxidized forms of 17.3% and aliphatic alkanes of 14.3% In addition the considerable amounts of hazardous air pollutants (e.g benzene chloro-benzene and chloro-alkanes) and compounds (e. g, aliphatic alkenes) with high potential of ozone or photochemical smog formation were identified from the incineration experiment of the SSWs.

  • PDF

Burning-Temperature Change of Living Branches and Leaves of Pinus rigida and Larix leptolepis (고온로의 가열 온도에 의한 리기다소나무와 일본잎갈나무 생엽과 생지의 연소온도변화)

  • Kim, Kwan-Soo;In-Soo Jang;Ki-Don Park;Su-Jung Kim
    • The Korean Journal of Ecology
    • /
    • v.18 no.3
    • /
    • pp.333-340
    • /
    • 1995
  • This study aims to examine how the amount of sample and changes in combustible temperature of living branches and leaves treated with high temperature are associated with combustible time of two coniferous trees, Pinus rigida (R) and Larix leptolepis (L), which are the main victims of forest fire. During the first thirty minutes at $80^{\circ}C$, moisture content of R was higher than that of L by 12%, but after four hours, the moisture content was both lowered by 4~5% and turned to highly combustible leaves. With living leaves, the maximal combustible temperature, regardless of heating temperature, turned out to be higher than normal temperature by $67~140^{\circ}C$, and that with living branches, it was higher by $113~207^{\circ}C$. Also, with living leaves (R, L), the duration time of combustion was as follows: 605, 906 seconds at $400^{\circ}C$ and 76, 227 seconds at $600^{\circ}C$, respectively. Concerning the relation between the amount of burnt fuel and maximal temperature, the more the former was, the higher the latter. The total amounts of combustion heat of living branches and living leaves were 1, 121 Cal (20.8%) and 1, 137 Cal (21.4%), respectively. The total amount of combustion heat increased in proportion to the amount of consumed fuel: 100 g of living leaves and branches gave rise to 128 Cal, whereas 300 g did 556 Cal, that was more than three times.

  • PDF

The Comparative Study on Preference of Combustible Moxibustion and Electronic Moxibustion (연소식 구(灸)치료와 전자식 구(灸)치료의 선호도에 대한 비교연구)

  • Ji, Min Jung;Hwang, Min Hyok;Lim, Seong Chul;Kim, Jae Soo;Lee, Hyun Jong;Lee, Bong Hyo;Jung, Tae Young;Seo, Jung Chul;Lee, Yun Kyu
    • Journal of Acupuncture Research
    • /
    • v.31 no.4
    • /
    • pp.133-141
    • /
    • 2014
  • Objectives : The purpose of this study is reporting to compare the preference of combustible moxibustion and electronic moxibustion. Methods : 31 patients were treated by combustible moxibustion in the morning and electronic moxibustion in the afternoon for 1 day. After they were treated by each moxibustions treatment, filled out questionnaire. We repeated the above process for 3 days. And we analyzed questionnaire statistically. Results : Heat sensitivity of electronic moxibustion has statistical significance. Sex and age have no statistical significances. Heat sensitivity and persistency of combustible moxibustion, heat persistency of electronic moxibustion also have no statistical significances. Satisfaction and smoke of moxibustion have correlation to moxibustion preference. Conclusions : Heat sensitivity of electronic moxibustion, satisfaction and smoke of moxibustion have correlation to moxibustion preference.