• Title/Summary/Keyword: collimator

Search Result 488, Processing Time 0.046 seconds

Study on Sensitivity and Resolution of Multihole Focusing Type Collimator (다공초점형(多孔焦点型) 콜리메타의 감도(感度)와 해상력(解像力)에 관(關)한 검토(檢討))

  • Park, Sung-Ock;Kyong, Kwang-Hyon;Park, Jun-Chul
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.63-70
    • /
    • 1982
  • In order to estimate characteristics and functions of multi hole focusing type collimator, the authors measured the sensitivity and resolution varing with the distance between the face of collimator and source by experimental study. The results obtained with this study are as follows. 1. In comparison with focal distance obtained fram sensitivity measurement of various multi hole focusing type collimator, collimator A, C, E was 10 cm and collimator B, D was 12 cm in focal distance. 2. In regard of resolution of collimators having 10 cm focal distance, collimator A showed the finest resolutions than any other collimator(C, E). 3. By comparison regarding sensitivity by focal dist ante, the shorter the distance than a give focal distance of collimator, the worse the sensitivity of collimator. 4. With regard to resolution by focal distance, the shorter the distance than a given focal distance of collimator, the worse the resolution of collimator.

  • PDF

Correlation Between High-Sensitive Collimator and Quantitave Analysis in Lung Ventilation SPECT (폐 환기 SPECT에서 고감도 Collimator와 정량분석의 상관관계)

  • Kim, Jung-Soo;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.89-99
    • /
    • 2015
  • This study investigated the correlation between the characteristics of collimator in accordance with the efficiency of detecting photon signals and the quantitative analysis of the lung function, thereby assessing the possibility of clinically applying high sensitivity lung ventilation SPECT. From March to May, 2014, 10 subjects in normal volunteers underwent an ultra high resolution, high resolution and high sensitivity collimator planar scan and SPECT. The experiment showed that compared with the collimator scan, the quantitative analysis results were significant (p=0.89), and compared to the high resolution collimator SPECT, the time was reduced by 4.9 fold. Therefore, the lung ventilation SPECT that had not been used due to an undermined effectiveness can offer usefulness when clinically applied if a high sensitivity collimator is used since the quality and quantity of information and the duration of scan time all offer an improvement.

Usability Evaluation by Development of IRIS Type X-ray Collimator (조리개형 X선 콜리메이터의 개발에 따른 유용성 평가)

  • Kang, In-Seog;Park, Jae-Yoon;Lim, Cheong-Hwan;Choi, Jae-Ho;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.249-254
    • /
    • 2018
  • In this study, we evaluated the DAP(Dose Area Product) reduction effect of the newly developed IRIS collimator by measuring the DAP of the Rectangle collimator and the IRIS collimator depending on the field, SID(Source to Image recpetor Distance) change, and AEC mode use. The results were as follows. The IRIS collimator decreased DAP by 34.91, 29.33, and 29.04%, respectively, compared to the Rectangle collimator when the field was increased to $8{\times}8$, $12{\times}12$, $16{\times}16inch$. And also, when the SID was increased to 100, 120 and 140 cm, the IRIS collimator decreased DAP by 10.73, 33.68 and 46.22%, respectively, compared to the Rectangle collimator. In AEC mode and none-AEC mode, DAP in IRIS collimator was reduced by 32.71 and 21.69%, respectively, compared with the Rectangle type. The IRIS collimator can reduce DAP by 29.62% on average compared to Rectangle type, which is statistically significant. These results suggest that the newly developed IRIS collimator can be used in medical field to alleviate radiation exposure.

The study of the optimized collimator structure for gamma-ray detector (감마선 탐지장치를 위한 Collimator 구조 최적화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.835-836
    • /
    • 2014
  • In this paper, we have designed the collimator of different sizes structure for the development of stereo radiation detector. And we conducted a study of the optimal structure of collimator using the results of the Gamma-ray irradiation test associated with the change of the incident angle. According to the results of the performance analysis, and showed the results of the optimal incident angle 2. Results of the paper are used as basic data for designing the structure of the detector efficiency for radiation detection.

  • PDF

Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation

  • Kim, Minho;Bae, Jae Keon;Hong, Bong Hwan;Kim, Kyeong Min;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.539-545
    • /
    • 2019
  • Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons.

The study of collimator and radiation shield for the detection of the gamma-ray distribution (감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.944-945
    • /
    • 2016
  • Gamma-ray Detector for gamma-ray imaging device is composed of a shielding body for shielding gamma-rays incident from the radiation source. Distribution of the gamma ray can be represented by the distribution information on the direction in which the detecting section and the signal through the incident hole of collimator. The role of the shield is important because all signals should be treated as noise except for the signal from the incident hole.In this paper In this paper, we have produced a compact, lightweight and Collimator shield by changing the structure and physical properties with respect to the collimator and shielding of lead-based gamma-ray detectors. And we analyzed the shielding effectiveness relative to the incident gamma ray sphere measured signal value through the gamma irradiation test facility. The results confirmed that the production and Collimator shielding the imaging device Implementing more efficient to implement.

  • PDF

Measurement technology of performance evaluation of optical collimator with high-functionality (고기능 광콜리메이터 성능평가 측정 기술)

  • Choi, D.S.;Je, T.J.;Hwang, K.H.;Kang, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1355-1360
    • /
    • 2003
  • Currently, product of optical collimator for optical communication is depending on handiwork, and some companies are propelling semi-automatic system composite of manual and automatic operations. In this point of time, the importance of automatic system of optical collimator for optical communication is taking its place as a core technology in the development of parts with high-efficiency of optical communication. In order to develop such an optical collimator in this study, we designed an automatic assembly system, and developed a software for the system operation. At a result of that, we could carry out a single work process individually running processes of collimator fabrication, a constant work process constantly running all of the processes, and performance evaluation of the collimator.

  • PDF

Novel Telecentric Collimator Design for Mobile Optical Inspection Instruments

  • Hojong Choi;Seongil Cho;Jaemyung Ryu
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.263-272
    • /
    • 2023
  • A collimator refers to an optical system that images a collimated beam at a desired point. A resolution target located at a near distance can be converted into a virtual image located at a long distance. To test the resolution for mobile cameras, a large target is placed at a long distance. If a collimator system is used, the target can be placed at a near distance. The space required for a resolution inspection can thus be drastically reduced. However, to inspect a mobile camera, the exit pupil of the collimator system and the entrance pupil of the mobile camera must match, and the stop of the collimator system must be located on the last surface. Because a collimator system cannot be symmetrical with respect to the stop, the distortion becomes extremely large, which can be corrected by combining the collimator symmetrically with respect to the object plane. A novel system was designed to inspect an optical lens on a mobile phone. After arranging the refractive power, lenses were added using the equivalent lens design method. The distortion was reduced to less than 1%. This optical system satisfies a half-field angle of 45° and an optical performance sufficient for inspection.

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Spectral resolution evaluation by MCNP simulation for airborne alpha detection system with a collimator

  • Kim, Min Ji;Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1311-1317
    • /
    • 2021
  • In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and an air filter, was developed. A collimator applied to the alpha detection system showed an enhancement in resolution and a degradation in detection efficiency. The resolution and detection efficiency were compared and analyzed to evaluate the performance of the collimator. Thus, the resolution was found to be more important than the efficiency as a determining factor of the detection system performance, from the viewpoint of radionuclide identification. The performance was evaluated on three properties of the collimator: hole shape, hole length, and the ratio between the hole and frame pitches. From the hole shape performance evaluation, a hexagonal collimator showed the highest resolution. Further, the collimator with a hole pitch of 14 mm was found to have the highest resolution while that with a frame pitch of 4-6 mm (i.e., 1.2-1.4 times longer than the hole pitch) showed the highest resolution.