• Title/Summary/Keyword: collector efficiency

Search Result 326, Processing Time 0.021 seconds

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

Effect of Coagulants on the Behavior of Ultra Fine Dust in a Coal Firing Boiler (석탄 화력 보일러에서의 응집제 이용에 따른 초미세먼지 거동)

  • Ryu, Hwanwoo;Song, Byungho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.84-89
    • /
    • 2020
  • Particulate matters of PM2.5, particularly focusing on 0.1~1 ㎛ decrease the efficiency of dust-collector due to the brownian-motion. This study is to verify the effect of coagulant on the particle size distributions of potassium and PM2.5. The activated coagulant was spayed to the coal fired fluidized bed combustion boiler by the weight ratio of 1,200 : 1 = coal : coagulant, and the size distributions of captured particles at both the cyclone (FP) and electrostatic precipitator (EP) were measured. As the result of XRP analysis, the potassium content of FP increased to 13.33% (averagely from 1.65% to 1.87%) and, in EP at 17.68% (averagely from 1.65% to 2.03%). And it was confirmed by the particle size distribution analyzer and SEM image analysis that the distribution rates of PM2.5 decreased at 89.53% on average in FP, and at 88.57% in EP. The total dust concentration (mg/㎥) confirmed by tele-monitering system (TMS) decreased during the primary test from 2.6 to 1.7~1.9 and also the secondary test from 2.9 to 1.7~1.9.

A Sludge Collector Selection Model by Life Cycle Cost Analysis (LCC분석에 의한 슬러지수집기 선정 모델)

  • Lee, Seung-Hoon;Woo, Yu-Mi;Lee, Sung-Rak;Koo, Kyo-Jin;Hyun, Chang-Taek;Hong, Tae-Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.175-184
    • /
    • 2006
  • This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.

Effect of Agitation Speed and Air Rate on Separation Efficiency in Fly Ash Flotation (플라이애시 부유선별 과정에서 교반속도와 공기주입량 변화에 따른 영향 연구)

  • Kim, Min Sik;Kang, Heon Chan
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.45-54
    • /
    • 2018
  • This study aimed to investigate the effects of mechanical factors such as agitation speed and air rate in fly ash flotation. Specifically, we used thermal power plant fly ash with unburned carbon content of 3.4 to 3.7%. The effect of pH, agitation speed, collector dosage, and frother dosage - the key factors of froth flotation - showed unburned carbon recovery and unburned carbon content of 63% and 34%, respectively, when the dosage of safflower oil used as collector was 800 g/ton, pH was 7, agitation speed was 1,200 rpm, and frother dosage was 400 g/ton. The SEM/EDS analysis of fly ash in that case indicated that the spherical fly ash particles lowered the unburned carbon content as they floated with the air bubbles without being dissolved in the unburned carbon or settled in the ore solution. The other experiment of changing the mechanical factors such as agitation speed and air rate resulted in unburned carbon recovery and unburned carbon content of 74% and 67%, respectively, at air rate of 8 L/min and agitation speed of 900 rpm. The recovery and unburned carbon content increased as the low agitation speed and additional air injection decreased the strength of the eddy current in the ore solution and consequently prevented the floating of fine fly ash particles with unburned carbon. In addition, the recovery rate and unburned carbon increased further to 80% and 70%, respectively, showing the best performance when the agitation speed and air rate were lowered to 800 rpm and 6 L/min, respectively.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

Study of Degradation of Bisphenol A with $TiO_2$ Powder in CPC System (CPC (Compound Parabolic Collector) 내 이산화티탄을 이용한 비스페놀 A (Bisphenol A)의 분해에 관한 연구)

  • Hwang, An-Na;Park, Myung-Hee;Lim, Beom-Guk;Khim, Jee-Hyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.107-112
    • /
    • 2011
  • In this study, photocatalytic degradation and mineralization of bisphenol A (BPA), which has been listed as one of endocrine disruptors, were carried out in the CPC system using $Tio_2$ slurry and UVA irradiation. The degradation efficiency has been investigated under the controlled parameters including initial concentration (5, 10, 20 mg/L), dosage of $Tio_2$ (0.1, 0.5, 1.0 g/L), UVA power (0, 80, 120 W) and temperature (0, 20, 30). At 10mg/L of initial concentration, BPA was degraded above 80% after 10min, BPA were degraded 97% and 49% at 20 mg/L and 30 mg/L, respectively. At $Tio_2$ dosage was 0.1 and 0.5 g/L, the degradations of BPA showed similar trend and were about 70% after 1 hr, and the degradation of BPA was above 80% after 30 min at 1 g/L of $Tio_2$ dosage. The increase of degradation seem to be due to the increase in the total surface area, namely number of active sites, available for the photocatalytic reaction as the dosage of photocatalyst increased. When the UVA power was 120 W, BPA was degraded rapidly above 60% after 10min of reaction time. To investigate the effect of temperature, carried out experiment controlled temperature, there were no significant differences depending on the temperature. After 1hr, the degradation of BPA were 46%, 67%, and 69% at 10, 20 and $30^{\circ}C$.

An Experimental Study on the Structural Performance of Lateral Resistance in Steel Elevator Pit (강재엘리베이터 피트 측압저항 구조성능에 관한 실험적 연구)

  • Hong, Seong-Uk;Kim, Tae-Soo;Baek, Ki-Youl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • Steel elevator pit was developed for the purpose of minimizing the excavation, simplifying the construction of the frame and economical efficiency by improving the problems that occurred in the existing reinforced concrete. It is common to apply conventional RC method through excavation to underground structures such as underground floor collector well and elevator pit. In recent years, the use of steel collector well and steel elevator pits to reduce construction costs by minimizing the materials of steel and concrete has been continuously increasing. The steel elevator pit is an underground structure and then the performance of the welding part and the structure system is important. Specimen with only steel plate and concrete without studs could support the load more than 3 times than the specimen with deck only. Therefore, even if there is no stud, the deck (steel plate) rib is formed and the effect of restraining the steel plate and the concrete during the bending action can be expected. However, since sudden fracture in the elevator pit may occur, stud bolt arrangement is necessary for the composite effect of steel plate and concrete. It is expected that the bending strength can be expected to increase by about 15% or more depending with and without stud bolts.

A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity (PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구)

  • Haneol Lee;Gwangtaek Lee;So-Hee An;Ye Won Park;Gunhee Lee;Kee Jung Hong;Inyong Park;Sang Bok Kim;Daehoon Park;Yeawan Lee;Dong-Keun Song;Yong-Jin Kim;Bangwoo Han;Hak-Joon Kim
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.

A Field Verification Study on the Effect of Filter Layers on Groundwater Level Drop Characteristics, Permeability, Optimum Yield and Well Efficiency in the Unconfined Aquifer Well for Riverbank Filtration Intake (강변여과수 취수를 위한 충적우물에서 필터층이 수위강하특성, 투수성, 적정양수량 및 우물효율에 미치는 영향에 대한 현장실증 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.509-529
    • /
    • 2019
  • This study performs to evaluate the role of filter material at alluvial well for intake of riverbank filtration and the applicability and improvement effect of dual filter well. To achieve this objective, dual filter intake well and single filter intake well were installed with different filter conditions at riverbank free surface aquifer in soil layer then we evaluated filter material condition, permeability, optimum yield and well efficiency according to yield in drawdown test. As a results, we assumed forming dual filter layer minimizes sudden speed changes at boundary between aquifer and filter layer by cushioning of groundwater flow. This suppresses warm current then intake groundwater efficiently, therefore it seems decreasing peripheral groundwater level changes in spite of higher intake water amount than single filter intake well. Furthermore, we confirmed by test, installing dual filter improves permeability, optimum yield and well efficiency. The result will be used by combining with former study to set up standard of design/construction of dual filter intake well at alluvial aquifer layer. Furthermore, we expect this result will be used to prove application effect of dual filter intake well compared to single filter one and radial collector well which are mainly applied on riverbank filtration.

A New Strategy to Fabricate a Colloidal Array Templated $TiO_2$ Photoelectrode for Dye-sensitized Solar Cells

  • Lee, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.8.1-8.1
    • /
    • 2011
  • Nanocrystalline titanium dioxide ($TiO_2$) materials have been widely used as an electron collector in DSSC. This is required to have an extremely high porosity and surface area such that the dye can be sufficiently adsorbed and be electronically interconnected, resulting in the generation of a high photocurrent within cells. In particular, their geometrical structures and crystalline phase have been extensively investigated as important issues in improving its photovoltaic efficiency. In this study, we present a new strategy to fabricate a photoelectrode having a periodic structured $TiO_2$ film templated from 1D or 3D polystyrene (PS) microspheres array. Monodisperse PS spheres of various radiuses were used for colloidal array on FTO glasses and two types of photoelectrode structures with different $TiO_2$ materials were investigated respectively. One is the igloo-shaped electrode prepared by $TiO_2$ deposition by RF-sputtering onto 2D microsphere-templated substrates. At the interface between the film and substrate, there are voids formed by the decomposition of PS microspheres during the calcination step. These holes might be expected to play the predominant roles as scattering spherical voids to promote a light harvesting effect, a spacious structure for electrolytes with higher viscosity and effective paths for electron transfer. Additionally the nanocrystalline $TiO_2$ phase prepared by the RF-sputtering method was previously reported to improve the electron drift mobility within $TiO_2$ electrodes. This yields solar cells with a cell efficiency of 2.45% or more at AM 1.5 illumination, which is a very remarkable result, considering its $TiO_2$ electrode thickness (<2 ${\mu}m$). This study can be expanded to obtain higher cell efficiency by higher dye loading through the increase of surface area or multi-layered stacking. The other is the inverse opal photonic crystal electrode prepared by titania particles infusion within 3D colloidal arrays. To obtain the enlargement of ordered area and high quality of crystallinity, the synthesis of titania particles coated with a organic thin layer were applied instead of sol-gel process using the $TiO_2$ precursors. They were dispersed so well in most solvents without aggregates and infused successfully within colloidal array structures. This ordered mesoporous structure provides the large surface area leading to the enough adsorption of dye molecules and have an light harvesting effect due to the photonic band gap properties (back-and-forth reflection effects within structures). A major advantage of this colloidal array template method is that the pore size and its distribution within $TiO_2$ photoelectrodes are determined by those of latex beads, which can be controlled easily. These materials may have promising potentials for future applications of membrane, sensor and so on as well as solar cells.

  • PDF