• Title/Summary/Keyword: collecting shoe

Search Result 8, Processing Time 0.025 seconds

The Study on the Third Rail Current Collecting Characteristics for Light Rail Transit (경량전철 제 3궤조 집전특성에 관한 연구(I))

  • 정락교;김연수;박성혁;목진용;이정식
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.530-536
    • /
    • 1998
  • In the design of the light rail transit which is more reliable and economical, it is essential to develope a efficient third rail system. Especially, the analysis for the conductivity of conduct rail and the wear of collecting shoe is the first step of its development. In this paper, experiments for conductivity in conductor rail, wear in collecting shoe were performed respectively as different materials of conductor rail and current collector. Noise level and interruption, wear and contact resistance of collecting shoe were proposed as design parameters for the development of this system. Experimental equipment and methods of design parameter stated above were proposed, which is expected that analyzed results will be used as a basic data for the development of the system.

  • PDF

A study on the performance increasing of current collecting system with a sliding contact (슬라이딩 접촉에 의한 집전시스템의 성능향상의 연구)

  • Jeong, R.G.;Kim, Y.S.;Yoon, Y.Ki.;Park, S.H.;Chung, S.G.;Lee, B.S.;Mok, J.Y.;Choi, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.455-457
    • /
    • 1999
  • In this paper, the wearing characteristics of current collecting shoes, interruption phenomena and contact resistances between collecting shoes and conductor rails are established as design parameters for development of the third rail current collector. An experimental analysis for established design parameters is performed as the materials of current collector shoe, contact force, sliding velocity and contact condition(dry/wet condition) between current collectors shoe and conductor rails. As a result of this study, the magnitude of contact force is in proportion to the amount of wear in the collecting shoe, but is in inverse proportion to the interruption and contact resistance between the collecting shoe and the conductor rail. And optimal values of design parameters are pre sented through analyzing the experimental results of the amount of wear, interruption and contact resistance.

  • PDF

Effects of High-heeled Shoe with Different Height on the Balance during Standing and Walking (하이힐 높이에 따른 균형성)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.479-486
    • /
    • 2010
  • The purpose of this study was to determine the effects of high-heeled shoe on the quiet standing and gait balance. Twenty women (mean height: $161.6{\pm}3.3\;cm$, mean body mass: $53.8{\pm}6.3\;kg$, mean age: $23.8{\pm}2.7$ yrs..) who were without history or complain of lower limb pain took part in this study. They were asked to stand quietly on a force platform for 30 sec and walk on it at their preferred walking speed (mean speed $3.14{\pm}0.5\;km/hr$.) with wearing three different high-heeled shoe, 3, 7, 9 cm high for collecting data. Data were randomly recorded to collect two trials for quiet standing and five trials for walking The parameters to have been analyzed for comparison between three conditions of the height of high-heeled shoe were COP(Center of Pressure) range, COP velocity, sway area, and free moment on the static balance and COP range, COP velocity, and free moment on the dynamic balance. In this study, high-heel height affected on the COP range and velocity in the ante-posterior direction during walking, dynamic balance, but didn't affect on the quiet standing, static balance.

The Analysis on the Structural Relation of Brand Image, Brand Reliability, Brand Loyalty and Purchase Intention of Sports Product Customers who contacted the Sports Product Collectors' Introduction (스포츠 상품 수집가의 스포츠 제품 소개를 접한 소비자의 브랜드 이미지, 신뢰도, 충성도, 구매의도간의 구조관계 분석)

  • Lee, Young-Jun;Oh, Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.840-852
    • /
    • 2019
  • The influences of sporting shoe brands wants to exert on consumers in the sports shoe market has been tried in many forms, and its effectiveness has also been proven. A variety of marketing strategies are being proven by each brand that they consider to be worth using. However, marketing strategies using sports shoe collectors have never been empirically proven in their influence. This is because the collecting behaviors shown in the traditional sports shoe market is very low in comprehension. This study was initiated by critical thought that determined a new marketing strategy was needed in the sports shoe market, which is considered to be somewhat limited, and is aimed at setting and demonstrating the path to influence in establishing a marketing strategy using sports shoe collectors. To achieve the purposes of this study, 231 consumers who were exposed to stimuli for describing the products of a hypothetical sports shoe collectors were used. For data analysis, frequency analysis, reliability analysis, correlation analysis, and confirmative factors analysis and structural equation method using PASW 21.0 and AMOS 20.0 were used. Based on the results derived from this study, we have found a new path to a new marketing strategy based on the expertise held by sports shoe collectors in the sports shoe market, which we hope will serve as one of the new growth engines for the sluggish sports shoe market in Korea.

Comparison of Step Counting Methods according to the Internal Material Molding Methods for the Module of a Smart Shoe

  • Jang, Si-Woong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.90-99
    • /
    • 2021
  • Recently, studies on wearable devices in ubiquitous computing environments have increased and the technology collecting user's activities to provide services has received great attention. We have compared the step counting methods according to sensor molding methods in case of counting steps by using the piezoelectric sensor. We have classified the cases which could result from the course of molding the internal module of a smart shoe as follows: (i) the module is unmolded, (ii) molded but only to the extent that a sensor is fixed or (iii) molded to the extent that a sensor is not moved. Moreover, we have made comparison to verify which algorithm should be used to increase the accuracy of counting steps by the respective cases. Based on the comparison result, we have confirmed that the accuracy of counting steps is higher when using gradient value rather than when using threshold value. In the case of no molding and small molding under the condition of using gradient value, it was turned out to be 100% accuracy for step counting.

The Development of Third-Rail System Applied to Turn-out Section for Urban Maglev (도시형 자기부상열차 분기기 구간의 제3궤조 전차선 시스템 개발)

  • Min, Byong-Chan;Heo, Young-Tae;Hong, Du-Young;Lee, Won-Joo;Jo, Su-Yeon;Jeong, Nam-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3046-3051
    • /
    • 2011
  • The third-rail system is an important device supplying power directly to the Maglev train through physical contact with the collecting shoe. It is directly related to safety and reliability for the running of Maglev. However, most the third-rail system used in Korea depend on foreign product or technologies, Korea Urban Maglev in the development of appropriate power feeding is urgent. In particular, the turnout section is the weakness point in the system because bending force by turnout section movement and fatigue caused by repetitive motion as well as the expansion by temperature, the forces by Maglev collecting shoe is added th the third-rail. Therefore, this paper proposes the third-rail system appropriate for Korean Urban Maglev of turnout section. To verify the structural stability of POSCO ICT third-rail system, the finite element analysis and physical testing was performed. The third-rail is fixed on each side of the turn-out section steel structure by epoxy insulation supporter and the integral behaviors are occurred. Therefore, the maximum horizontal displacements of each support are investigated and then, it is applied to finite element model of the third-rail to investigate the moments and stress. Also, the bending test about one million times and Expansion Joint for the third-rail was performed. The third-rail system safety and reliability was identified by test line on Korea Institute of Machinery & Materials in Deajeon for under the actual usage environment such as the Maglev and turn-out operation.

  • PDF

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.