• 제목/요약/키워드: cold plate

검색결과 343건 처리시간 0.03초

전기자동차용 Cold Plate의 열전달 및 압력손실 특성 연구 (Heat Transfer and Pressure Drop Characteristics of the Cold Plate for an Electric Vehicle)

  • 함진기;이준엽;송석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1566-1571
    • /
    • 2003
  • The cold plate used for a CEU(Control Electronics Unit) of an EV(Electric Vehicle) is extremely important since the dissipation of the heat generated from power devices like IGBT(Insulated Gate Bipolar Transistor) and diode has a significant effect on the performance as well as the durability of the CED. The cold plate consists of seven power devices, and coolant flows through the passage bonded to a groove of the cold plate. In order to find out heat transfer and pressure drop characteristics, series of numerical analyses for the cold plate with enhanced coolant passages were conducted. Based on results of the numerical analyses, an improved model of the cold plate has been proposed. The experiments under the various conditions have been conducted to compare the performance of the proposed cold plate to the present one. As a result of the numerical analyses together with the experiments, the ideal design of the cold plate could be offered.

  • PDF

로봇 냉각을 위한 수냉식 냉각판의 성능 평가 (Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 이석원;강상우;황규대;김서영;리광훈
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.

유한요소법과 최적설계기법을 활용한 히트싱크 콜드 플레이트 최적 설계 (Optimized Design of a Cold Plate Heat Sink using FEM and Optimization)

  • 홍석무;서형준;김종문;심재원;황지훈
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.419-424
    • /
    • 2014
  • In order to improve efficiency, an outdoor unit using a refrigerant cooling method is designed into many air conditioner systems. The heat exchanger is composed of a Cu tube and an plate. The optimal design for the cold plate is very important because the efficiency of the heat transfer depends on the contact area between the Cu tube and the cold plate. The current study focused on the design of the cold plate to obtain a uniform contact between the Cu tube and the cold plate. Both FE(finite element) analysis and optimization were used in the design. The contact area between the tube and plate was predicted and improved by 16% through the press forming simulations. The springback after press forming was also reduced when the optimized design parameters were used. To verify the validity of the optimal cold plate design, a verification test was conducted. As a result, the performance of the heat exchanger improved by 34% when compared to benchmarked products.

FEM해석을 이용한 후판 냉간교정 연구 (Research on Cold Leveler in Thick Plate Mill using FEM)

  • 이종빈;천명식;박해두
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.233-235
    • /
    • 2007
  • Finite element analysis was conducted for cold roller leveler to verify numerical model of roller leveler developed by POSTECH. On-line model of roller leveler was developed to predict rapid and precise roll intermesh of roller leveler in thick plate mill. The cold roller leveler in thick plate mill was analyzed using MARC & MENTAT and the results are compared with the results of numerical model of roller leveler calculated by POSTECH.

  • PDF

Cold plate를 이용한 휴대용 컴퓨터 냉각 시스템의 열성능에 관한 연구 (A Study on Thermal Performance of Cooling System for a Laptop Computer Using a Cold Plate)

  • 박상희;조남해;최성대
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.83-89
    • /
    • 2009
  • This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.

  • PDF

알루미늄 냉각 판을 이용한 하이브리드/전기차용 배터리 냉각시스템의 수치적 연구 (Thermal Analysis of a Battery Cooling System with Aluminum Cooling Plates for Hybrid Electric Vehicles and Electric Vehicles)

  • 백승기;박성진
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.60-67
    • /
    • 2014
  • The battery cells in lithium-ion battery pack assembled with high-capacity and high-power pouch cells, are commonly cooled with thin aluminum cooling plates in contact with the cells. For HEV/EV lithium-ion battery systems assembled with high-capacity, high-power pouch cells, the cells are commonly cooled with thin aluminum cooling plates in contact with the cells. Thin aluminum cooling plates are cooled by cold plate with coolant flow paths. In this study, the effect of the battery cooling system design including aluminum cooling plate thickness and various position of cold plate on the cooling performance are investigated by using finite element methods (FEM). Optimal cooling plate and cold plate design are proposed for improving the uniformity in temperature distributions as well as lowering average temperature for the cells with large capacities based on the simulation results.

수소저장금속의 형상과 변형 (Shapes and Deformation of the Hydrogen Absorption Metal)

  • 정영관;박규섭;이근진;김경훈;김세웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1382-1385
    • /
    • 2003
  • Deformation on shapes of the hydrogen absorption metal in this paper was investigated on hydrogen absorption-desorption cycling. In order to study this problem, the cold rolled palladium plate and the cold extrusion palladium bar as specimens had been used. By using the electrochemical method, the palladium specimens were cyclically hydrogenated in the 0.1 mol H$_2$SO$_4$ electrolyte. As results, it is noted that the thickness of the plate specimen gradually increased in increasing hydrogenation cycles whereas the width and the length decreased. But both the diameter and the length of the bar specimen increased with increasing hydrogenation cycles. Also, grains in the plate specimen were greatly deformed after hydrogenation cycling whereas internal grains in the bar specimen were pulverized. And deterioration of the hydrogen absorption rate of the bar specimen was lager than the plate specimen.

  • PDF

수소저장-방출싸이클링과 냉간가공과의 관계 (The Relation between Hydrogen Absorption-Desorption Cycling and Cold Work)

  • 정영관;이근진;박규섭;김경훈;김세웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.829-832
    • /
    • 2002
  • Deformation of the specimens was investigated on hydrogen absorption-desorption cycling. In order to study this problem, the cold rolled and the annealed palladium thin plate as specimens had been used. By using the electrochemical method, the palladium plate specimens were cyclically hydrogenated in the 0.1mol $H_2SO_4$ electrolyte. As results, it is noted that the thickness of the plate specimens gradually increased in increasing hydrogenation cycles whereas the width and the length decreased. Also, Deformation of the cold rolled palladium specimen was lager than the annealed palladium specimen. And grains in the plate specimen were greatly deformed after hydrogenation cycling. But hydrogen absorption rate scarcely changed.

  • PDF

Local buckling and shift of effective centroid of cold-formed steel columns

  • Young, Ben
    • Steel and Composite Structures
    • /
    • 제5권2_3호
    • /
    • pp.235-246
    • /
    • 2005
  • Local buckling is a major consideration in the design of thin-walled cold-formed steel sections. The main effect of local buckling in plate elements under longitudinal compressive stresses is to cause a redistribution of the stresses in which the greatest portion of the load is carried near the supporting edges of the plate junctions. The redistribution produces increased stresses near the plate junctions and high bending stresses as a result of plate flexure, leading to ultimate loads below the squash load of the section. In singly symmetric cross-sections, the redistribution of longitudinal stress caused by local buckling also produces a shift of the line of action of internal force (shift of effective centroid). The fundamentally different effects of local buckling on the behaviour of pin-ended and fixed-ended singly symmetric columns lead to inconsistencies in traditional design approaches. The paper describes local buckling and shift of effective centroid of thin-walled cold-formed steel channel columns. Tests of channel columns have been described. The experimental local buckling loads were compared with the theoretical local buckling loads obtained using an elastic finite strip buckling analysis. The shift of the effective centroid was also compared with the shift predicted using the Australian/New Zealand and American specifications for cold-formed steel structures.

냉간 성형용 열연 고강도 강판의 교정 중 잔류음력 변화와 절단 후 camber 발생 거동 연구 (Residual Stress Evolution during Leveling of Hot Rolled Cold Forming Purpose High Strength Coils and Camber Prediction)

  • 박기철;류재화
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.112-115
    • /
    • 2007
  • In order to investigate the residual stress evolution during the leveling process of hot rolled high strength coils for cold forming, the in-plane residual stress of plate sampled at SPM, rough leveler and finish leveler were measured by cutting method. Residual stress was localized near the edge of plate. As the thickness of plate was increased, the region with residual stress was expanded. The gradient of residual stress within plate was reduced during the leveling process. But the residual stress itself was not removed at the ranges of tested conditions. From the measured residual stress distribution within the plate, camber of plate cut to small width was predicted exactly within error range of experiment.

  • PDF