• Title/Summary/Keyword: cold period

Search Result 966, Processing Time 0.026 seconds

Storage Characteristics of Rough Rice by Storage Method (저장방법에 따른 벼의 저장특성)

  • Lee, J.S.;Hong, H.K.;Kang, T.H.;Li, H.;Ham, T.M.;Kim, Y.H.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • The objective of this study was to investigate the adequate storage method that was able to maintain the high quality of rough rice according to storage methods and period. The quality change of the rough rice during the storage period was evaluated by storage method such as cooling bin using winter cold air, ordinary temperature bin, freezing, refrigeration and indoor storage. Moisture content, brown rice whiteness, hardness, crack ratio and germination ratio were measured in this study. Moisture content of rough rice stored in cooling bin using winter cold air and ordinary temperature bin were decreased by 0.07% and 0.42%, respectively, which were lower than the other storage method. The hardness of brown rice increased in order of storage method such as winter cooling bin, normal bin, freezing storage, refrigeration storage and indoor storage. Crack ratio by indoor and ordinary temperature bin storage were increased by 2.68% and 3.63%, respectively, whereas cooling bin using winter cold air, refrigeration and freezing storage showed below 1.0%. The highest germination rate was found in cooling bin using winter cold air. As a result, cooling bin using winter cold air can be evaluated for the adequate storage method of rough rice.

A Study on Latent-gi by Yexiangyan "Wenrejingwei" ("온열경위(溫熱經緯)" 중(中) 섭향암(葉香巖)의 삼시복기외감(三時伏氣外感)에 관한 연구(硏究))

  • Ahn, Joon-Mo;Song, Ji-Chung;Jeong, Hyun-Jong;Keum, Kyung-Soo
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.16 no.2
    • /
    • pp.163-187
    • /
    • 2010
  • The concept of latent-gi(伏氣) was first mentioned in Yellow Emperor's Canon of Internal Medicine. For example, Elementary Questions states, "Damage by cold in winter necessarily engenders warm disease in the spring." Zhang Zhong-Jing of Han Dynasty in On Cold Damage and Miscellaneous Diseases mentions warm disease, stating, for example, "Greater yang disease with heat effusion and cough and without aversion to cold is warm disease. If sweating is applied, and there is generalized heat, this is wind warmth." However, the concept of warm disease was not central to his systematic presentation of externally contracted disease which placed the emphasis on wind and cold as the major causes of these diseases. Zhang Zhong-Jing's theories centuries after in the Sung Dynasty were to become the focus of the cold damage school, whereas the concept of warm disease was to become the focus of a rival school, the warm disease school. In the Sui-Tang Period, The Origin and Indications of Disease mentions warm diseases, their causes, patterns, and major principles of treatment. Successive generations of doctors wrote about warm disease, and in the Ming Dynasty writings on the subject become more prolific. This development is attributable on the one hand to the opening up of the south of China where febrile diseases tended to be of a different nature than in the north, and on the other to pestilences arising as a result of wars. In this period, Wu You-Xing in On Warm Epidemics explained in detail the laws governing the origin, development and pattern identification of warm epidemics. Notably, he posed the etiological notion of a contagious perverse gi.

  • PDF

Effect of cold storage method for 'Sulhyang' strawberry mother plants on mother plant growth and the number of runners and daughters

  • Lee, Inha;Kim, Hyun-Sook;Nam, Myeong Hyeon;Oh, Sang-Keun
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.625-632
    • /
    • 2020
  • This test was conducted to determine the appropriate conditions of temperature, storage period, and soil moisture content when using cold storage of potted mother plants of as a means of sufficient dormant breaking and safe overwintering of the strawberry (Fragaria × ananassa Duch. cv. Sulhyang) mother plants. In the treatment by temperature for the dormant breaking of strawberry mother plants, the survival rate of natural overwintering was 91%, whereas the survival rate was 100% at 0, - 2, and - 5℃. As the storage temperature was decreased, the plant height of the mother plants became shorter which tended to decrease after planting. Survival of the mother plants was possible at - 5℃, but after planting, the growth and number of daughter plants decreased significantly. The number of daughter plants was highest at 22.8 per plant at - 2℃ storage. The strawberry mother plants could be stored for up to 8 months in cold storage. However, when the mother plants were stored for a long period, the number of daughter plants was small. When they were stored for 4 months, the growth of the mother plants was vigorous, and the number of runners and daughter plants was high. When the water content of the soil was less than 10 percent (%, w/w) in the cold storage of the pot, the survival rate was 85 percent, which was high due to the dryness. The survival rate was 100 percent at 30 and above, and the growth of the mother plants after planting and the number of daughter plants were high at 30 to 50.

Carbonation Behavior of GGBFS-based Concrete with Cold Joint Considering Curing Period (재령 변화에 따른 콜드조인트를 가진 GGBFS 콘크리트의 탄산화 거동)

  • Cho, Sung-Jun;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.259-266
    • /
    • 2018
  • In the work, the carbonation behavior and strength characteristics in cold-joint concrete are evaluated for OPC(Ordinary Portland Cement) and GGBFS(Ground Granulated Blast Furnace Slag)concrete considering three levels of curing age (28, 91 and 365 days). The compressive strength in GGBFS concrete is level of 86% of OPC concrete at the 91 days of curing period, but is level of 107% at 365 curing days due to hydration reaction. Carbonation velocities in both OPC and GGBFS concrete significantly decease after 91 curing days. The effect of cold joint on carbonation is evaluated to be small in GGBFS concrete. The increasing ratios of carbonation velocity in cold joint are 1.06 and 1.33 for 28-day and 365-day curing condition, respectively. However they decreases to 1.08 and 1.04 for GGBFS concrete for the same curing conditions.

Evaluation of Acute Respiratory Infections(ARI) Control Programme in a Korean Rural Community -The Patterns of Antibiotic Prescription- (한 농촌지역에서 실시한 소아 급성호흡기감염 관리사업의 평가 -항생제 사용을 중심으로-)

  • Lee, Young-Seong;Kim, Chang-Yup;Kim, Yong-Ik;Shin, Young-Soo;Ko, Jae-Wook
    • Journal of agricultural medicine and community health
    • /
    • v.18 no.2
    • /
    • pp.105-119
    • /
    • 1993
  • The purpose of this study was to evaluate the program for the control of acute respiratory infections(ARI) in children in a Korean rural area(Yonchon county). Evaluating the program, we focused on the pattern of prescription and appropriateness of antibiotics prescribed by the health personnel who had participated in the ARI Control Program. It was implemented at the primary health care setting in rural area, such as district hospital, health subcenters, and health posts. During six-months programme monitoring period, medical records were reviewed and collected data were analysed by the pediatrician, research coordinator of this study. The baseline data were collected from medical records of the same period(six months) of one year before the implementation of the ARI programme. The study results were as follow : 1. Common cold was the most prevalent disease(78.7%. 594 cases) among the all ARI cases (755 cases). The less frequent cases were bronchitis(11.9%), acute pharyngitis(5.2%), and pneumonia(1.8%). 2. Significant reduction in the use of antibiotics was observed after the programme implementation. Ninety three(15.7%) of 594 common cold cases were received antibiotics compared with 282(35.2%) of 802 in the baseline period. In the cases of bronchitis and acute pharyngitis, the reduction rates were 15.1% and 23.2% respectively compared to the baseline period. 3. Mean duration of antibiotics prescription was 1.81-1.75 days, similar to the baseline data. 4. The appropriateness rate of antibiotics prescriptions were 84.3%(common cold), 35.6% (bronchitis) and 28.2%(acute pharyngitis). In the case of pneumonia, the antibiotics prescription was compatible to the criteria developed. 5. Pediatrician prescribed antibiotics more appropriately for all cases than general practitioners in health sub-center, and nurse practitioners in health posts. 6. Antibiotics therapy was shown to be of no effect in the treatment of the all ARI cases. At the 5 and 10 days check-up of common cold cases after visits, proportion of improved patients were 58.3% in the antibiotics-used group and 51.4% in the control group. In the other cases of ARI, the patterns of response were similar to common cold. None of the differences in outcome between the antibiotics-used and control group was statistically significant. This ARI programme may have substantial a substantial impact on antibiotics use at the public health institutions(district hospital, health subcenters, health posts) which are of major domain for primary health care in Korean rural areas.

  • PDF

A Study for Fast Light-Off of a Catalyst During Cold Start (냉시동시 촉매의 예열시간 단축에 관한 연구)

  • Cho, Y.S.;Lee, Y.S.
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.69-77
    • /
    • 1998
  • In order to meet the stringent emission regulations, fast light-off of a catalyst is essential to reduce the HC and CO emissions during cold start. Cranking Exhaust Gas Ignition (CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds after cold start. The CEGI system cuts off the ignition signal for a few seconds during the cranking period. so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst. Results from the FTP-75 tests showed that the exhaust emissions with the CEGI reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF

Cold Storage of Sperm in Marbled Sole Limanda yokohamae (문치가자미, Limanda yokohamae 정자의 냉장보존)

  • 장영진;고강희;임한규
    • Journal of Aquaculture
    • /
    • v.10 no.4
    • /
    • pp.381-386
    • /
    • 1997
  • A series of experiments were conducted to compare the effects of various diluents in cold storage on the marbled sole, Limanda yokohamae sperm. Various diluents of glucose, L. yokohamae serum, marine fish Ringer's solution, sodium citrate and Ca2+ free artificial seawater (ASM) (tris-HCI, pH 7.4) containing 3 mM ethylene glycol-bis (2-aminoethyl ether) tetraacetic acid (EGTA) were used to store the sperm at 4℃. The storage effect was evaluated using motility index and survival rate of sperm. Glucose and sodium citrate were found to be better diluents which maintained high motility and survival rate of sperm for a storage period of 10 days. Some morphological changes of spermatozoa were observed during the cold storage with diluents. In particular, a detachment of the nuclear enveloped and of the plasma membrane from the nucleus in spermatozoa was observed. Morphological normality of the stored spermatozoa diluted with 0.3 M glucose was better than that of the stored spermatozoa undiluted or diluted with Ca2+ free ASW containing 3 mM EGTA.

  • PDF

Mesoscale Features and Forecasting Guidance of Heavy Rain Types over the Korean Peninsula (한반도 호우유형의 중규모 특성 및 예보 가이던스)

  • Kim, Sunyoung;Song, Hwan-Jin;Lee, Hyesook
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.463-480
    • /
    • 2019
  • This study classified heavy rain types from K-means clustering for the hourly relationship between rainfall intensity and cloud top height over the Korean peninsula, and then examined their statistical characteristics for the period of June~August 2013~2018. Total rainfall amount of warm-type events was 2.65 times larger than that of the cold-type, whereas the lightning frequency divided by total rainfall for the warm-type was only 46% of the cold-type. Typical cold-type cases exhibited high cloud top height around 16 km, large reflectivity in the upper layer, and frequent lightning flashes under convectively unstable condition. Phenomenally, the cold-type cases corresponded to cloud cluster or multi-cell thunderstorms. However, two warm-type cases related to Changma and typhoon were characterized by heavy rainfall due to long duration, relatively low cloud top height and upper-level reflectivity, and the absence of lightning under the convectively neutral and extremely humid conditions. This study further confirmed that the forecast skill of rainfall could be improved by applying correction factor with the overestimation for cold-type and underestimation for warm-type cases in the Local Data Assimilation and Prediction System (LDAPS) operational model (e.g., BIAS score was improved by 5%).

Comparative Studies on Cold Responses wearing Traditional Costume of Korean and Japanese (한·일 양국민의 민족복 착용에 따른 한랭반응의 비교)

  • Sung, Su-Kwang;Yasukouchi, Akira
    • Fashion & Textile Research Journal
    • /
    • v.1 no.1
    • /
    • pp.69-73
    • /
    • 1999
  • Korean and Japanese, both people have a lot of similarity and complexity in terms of physical constitution and culture. This study might be the first implementation that tries to figure out constitutional differences of both people in scientific way. In this study, subjects were from each country, had been exposed $5^{\circ}C$ environment wearing each country's traditional costume- so called Hanbok and Kimono- and all through this experiment we'd compared physiological responses and analyzed differences of cold response go with their own clothing culture. We've obtained following results: Korean had kept maintaining low mean skin temperature basically in cold circumstance, compared with Japanese, have stronger cold tolerance. However, there's no significant difference between Korean and Japanese. Owing to huge influence of wearing other country's traditional costume itself even makes differences of rectal temperature in a cold environment. In addition, in a period of time that wearing other country's traditional costume, thermal sensation would be different according to exposed surrounding temperature.

  • PDF

Changes in Moisture Content and Quality of Oriental Hybrid Lily (Lilium oriental cv. Siberia) Cut Flowers during Storage at Cold and Dry Condition and Subsequent Exposure to Ambient Temperature (오리엔탈 나리 '시베리아' 절화의 포장내 건식저장 기간별 수분함량과 품질 변화)

  • Lee, Jung-Soo;Rhee, JuHee;Kang, Yun-Im;Choi, Ji Weon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • In order to determine the relationship between water content and flower qualities of oriental hybrid lily cv. 'Siberia' cut flower, flowers were subjected to dry and cold storage at $5^{\circ}C$ for 3, 6, and 12 days and subsequently exposed to ambient temperature ($26^{\circ}C$) in bottles with water for up to 16 days. Flowers stored at $22^{\circ}C$ in dry condition for 3 days were used as the control. Changes in fresh weight, moisture content, water balance, flowering stages, osmolality and vase life of cut flowers were observed. Flowers treated with cold and dry storage had higher moisture content compared to control sample. However, this trend was evident only for 3-day cold and dry stored sample during the whole storage period. The fresh weight of cut flowers increased gradually when the samples were transferred to ambient temperature in water bottles and then declined steadily before reaching the peak in between 6-8 days of vase life. However, the changes of fresh weight of control sample were substantially faster than samples pre-treated with cold and dry storage. This was also correlated with the water balance of cut flower as it reached the minus (-) value in 6-8 days of vase life at ambient temperature. Cut lily flowers showed high osmolality values corresponding with the duration of dry storage regardless of low or higher temperature. However, osmolality had no effect on vase life since flower stem absorbed water rapidly at the end of dry storage period. Our vase life results suggest that cold and dry storage of lily cut flowers for a certain period could ensure longer vase life at ambient temperature. It was observed that prolonging the storage period at cold and dry condition for more than a week significantly increased bud abortion, reduced longevity of flowers and reduced the vase life of cut flowers. On the other hand, the shorter cold and dry storage treatment delayed the bud opening and senescence of the flowers, thus, slowering the normal maturation and aging. Results indicated that dry and cold storage at $5^{\circ}C$ for 3 days was effective in maintaining and preserving overall quality and vase life at ambient condition of oriental hybrid lily cut flowers.