• 제목/요약/키워드: cold environment

검색결과 922건 처리시간 0.026초

도시 열환경을 고려한 녹지관리방안 수립 연구 (A Study on Green Space Management Planning Considering Urban Thermal Environment)

  • 주창훈;김정호;윤용한
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

압축냉각공기와 오일미스트를 이용한 환경친화 연삭가공기술 (Ecological Grinding Technology Using Compressed Cold Air and Oil Mist)

  • 이석우;최헌종;허남환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2002
  • The environmental problems by using coolant demanded the new cooling methods. As one of them, the studies on the finding with compressed cold air and oil mist have been done. The cooling method using compressed cold air was effective through going down the temperature of compressed air supplied below $-25^{\circ}$ and increasing the amount of compressed cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using oil mist newly were suggested. This method can satisfy both cooling effect and lubrication with only small amount of coolant, also have the benefit in the point of decreasing the environmental pollution. This paper focused on analyzing the grinding characteristics of the cooling method using oil mist. The grinding test according to compressed cold air, oil mist spray pressure and oil mist supply direction were done.

  • PDF

추위 훈련이 신체 조성에 미치는 영향 -체중, 체지방량, 골격근량을 중심으로- (Effect of Cold Acclimatization Training on Body Composition)

  • 박주희;최정화
    • 한국의류학회지
    • /
    • 제35권7호
    • /
    • pp.713-720
    • /
    • 2011
  • This study investigated the effect of cold acclimatization training on body composition including weight, fat mass, and muscle mass with 10 subjects (5 males and 5 females). During the 3-week acclimatization training program, they visited an artificial climate chamber ($15^{\circ}C$) 15 times and were exposed to cold environment with light clothing for 2 hours. Body composition was measured before and after cold training using bioelectric impedance analysis that was later compared by a paired t-test. In the process of thermoregulation, muscle contraction was accompanied by increased substrate metabolism for rising heat production. After cold training, the muscle mass increased and fat mass decreased significantly (p<.1, p<.05), subsequently the body composition changed. It was found that cold acclimatization training could be used as a treatment for obesity. It was suggested that further investigation on the long term effects of mild cold exposure using clothing and its potential applicability as an obesity treatment.

한파에 따른 표층수온의 지연시간 고찰 - 서해, 남해 - (Consideration of Time Lag of Sea Surface Temperature due to Extreme Cold Wave - West Sea, South Sea -)

  • 김주연;박명희;이준수;안지숙;한인성;권미옥;송지영
    • 해양환경안전학회지
    • /
    • 제27권6호
    • /
    • pp.701-707
    • /
    • 2021
  • 본 연구에서는 강한 한파가 발생했던 2018년과 온난 한파가 발생했던 2019년의 기온에 따른 수온의 반응 및 지연시간과 북풍계열 바람 빈도와의 상관관계를 분석하였다. 사용된 시간 자료는 국립수산과학원에서 제공하는 7개 지점 해역별 수온자료와 수온관측소 인근 7개 지점 AWS 기온자료를 이용하였다. 관측되지 못한 자료는 내삽법으로 근사값을 계산하였고, FIR Filter를 이용하여 자료의 주기성을 파악하였다. 그 결과, 강한 한파가 발생했던 2018년은 북풍계열 바람을 통해 차가운 공기가 남하하면서 기온을 하강시켜 전 해역에 저수온을 유발한 반면 온난 한파가 발생했던 2019년은 평년 수준의 기온으로 하강하였지만 수온은 크게 변화하지 않았다. 강한 한파가 발생했던 2018년 기온 하강에 따른 수온의 지연시간은 평균 14시간으로 0.7 이상의 높은 상관성을 나타냈고 온난 한파가 발생했던 2019년은 평균 지연시간이 20시간으로 0.44-0.67 사이의 상관성을 보였다. 본 연구를 통해 해역별로 기온 하강에 따른 표층수온의 반응을 해석하였고 지연시간을 파악함으로써 양식생물의 피해를 최소화하고 한파 피해의 신속한 대응에 기여할 수 것으로 기대한다.

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

도시환경개선을 위한 산림 기반 바람길 관리 계획 - 낙동정맥을 사례로 - (Management Planning of Wind Corridor based on Mountain for Improving Urban Climate Environment - A Case Study of the Nakdong Jeongmaek -)

  • 성욱제;손정민;엄정희;민진규
    • 한국지리정보학회지
    • /
    • 제26권1호
    • /
    • pp.21-40
    • /
    • 2023
  • 본 연구는 도시 환경 개선을 위한 방안으로 최근 관심이 높아지고 있는 바람길 관리방안을 제안하고자, 도시로 유입될 수 있는 찬공기 형성에 유리한 낙동정맥을 대상으로 찬공기 특성을 분석하였다. 또한 유역 분석을 기반으로 낙동정맥의 구체적인 바람길 유역을 설정하고 유역별 찬공기 기능 확대를 위한 방안을 제안하였다. 낙동정맥의 찬공기 분석 결과, 찬공기는 낙동정맥의 북부 산림에서 강하게 생성되었으며, 계곡 지형을 따라 인근 도시로 유입되었다. 평균적으로는 낙동정맥의 동쪽에 위치한 도시에서 찬공기 풍속이 높았으며, 반면 서쪽에 위치한 도시에서는 찬공기층 높이가 높게 나타났다. 이러한 찬공기 특성 및 유역 분석 결과를 종합하여 낙동정맥의 바람길 관리유역을 8개로 분류하였으며, 이를 '찬공기 기능 보전유역', '찬공기 기능 관리유역', '찬공기 기능 집중관리구역'으로 설정하여 정맥의 기온 저감 기능을 보전 및 강화하기 위한 방안을 제안하였다. 또한, 찬공기의 기온 저감 기능을 검증하고자 기상관측 정보를 활용하여 야간 기온 저감 효과를 찬공기 분석 결과와 비교하였다. 그 결과 찬공기 특성이 강한 지점의 관측소에서 야간 기온 저감 효과가 상대적으로 크게 나타나 찬공기의 기온 저감 기능을 확인할 수 있었다. 본 연구의 결과는 낙동정맥의 찬공기 기능 확대를 위한 체계적 보전 및 관리계획 마련 시 기초자료로 활용될 수 있을 것으로 기대한다.

WA 숫돌을 이용한 원통 연삭 시 압축냉각공기와 연삭유의 냉각효과에 관한 연구 (A Comparison of the Cooling Effects for the Compressed Cold Air and Coolant on the Cylindrical Grinding with WA Wheel)

  • 이석우;최헌종;정해도
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.155-161
    • /
    • 2000
  • Recently, environmental pollution has become a big problem in industry and many researches have been done in order to preserve the environment. In the grinding process, the coolant has great influence on environment. It contains several chemicals(sulfur, phosphorus and chlorine) to improve the grinding efficiency. If these additives go into the workplace atmosphere, it is harmful for workers. It can also cause the environment pollution. Because of these reasons many studies have been done to minimize the amount of coolant. However the small amount of coolant can cause the thermal defect on the ground surface layer. This study forced the effects of the compressed cold air when the spindle shaft materials(SCM4 & SCM21) were cylindrical ground with WA wheel. The compressed cold air was used as the coolant and grinding performance was compared with that of the conventional grinding fluids(emulsion). Many experiments were carried out with these two cooling materials. The surface roughness, residual stress, and roundness were measured for the cylindrical grinding. The test results showed that the compressed cold air was very useful as the cooling materials for grinding process. It was also efficient to minimize the thermal defects of workpiece and could also play a role in solving environmental pollution.

  • PDF

수도권지역 승용차에 의한 Cold Start와 Evaporative VOC를 고려한 배출량 추정 (Estimation of the Emission form Passenger Car Considering Cold Start and Evaporative VOC Emission in the Capital Area)

  • 장영기;최상진;홍영실
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.157-158
    • /
    • 2003
  • 급증하는 자동차 수요로 인해 발생되는 배출량 증가는 자동차 운행의 특성상 대도시 대기오염의 주원인으로 작용하고 있다. 자동차 배출오염물질의 배출량 추정 및 관리에 있어 연간 배출량 뿐만 아니라 월별 기온변화에 따른 배출량의 시간분포 또한 고려되어야 한다. 본 연구에서는 Hot emission에 부가되는 Cold start emission과 Evaporative VOC emission의 산정에 있어서 차종/차령에 대해서 월별 배출량을 추정하여 보았다. (중략)

  • PDF

무선인식 리더기와의 연동을 위한 이동 게이트웨이 구현에 관한 연구 (Implementation of Mobile Gateway Integrated RFID Reader)

  • 박진희;김희수;김대환
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.251-252
    • /
    • 2009
  • In smart cold chain, environment monitoring (for example temperature, humidity, and etc) is an important. Especially, because monitoring may be broken on passage, in order to success of cold chain management, it is important that seamless monitoring. To solve this problem, we implement mobile gateway supporting RFID and demonstrate using of RFID middleware emulator.

  • PDF

국내 승용차의 1회 평균 주행거리에 의한 Cold Start Emission과 Evaporative Emission 추정 (Estimation of the Cold Start Emission and Evaporative Emission by Passenger Cars Trip Length)

  • 장영기;최상진;신문기;조규탁
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.143-144
    • /
    • 2000
  • 급증하는 자동차 수요로 인해 발생되는 배출량 증가는 자동차 운행의 특성상 대도시 대기오염의 주원인으로 작용하고 있다. 자동차 배출오염물질의 배출량 추정에 있어 국내 차량의 배출계수 개발도 시급하지만 우리 나라 자동차 운행패턴에 관한 연구도 같이 병행되어야 한다. 본 연구에서는 Cold start emission과 Evaporative VOC emission의 산정에 있어서 국내 승용차의 1회 주행거리(Trip length)를 이용하여 승용차 부문 배출량 영향정도와 계절별 배출량 변화를 추정하여 보았다. (중략)

  • PDF