• Title/Summary/Keyword: coil array

Search Result 94, Processing Time 0.031 seconds

Design and Analysis of a Vibration-Driven Electromagnetic Energy Harvester Using Multi-Pole Magnet

  • Munaz, Ahmed;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.172-179
    • /
    • 2012
  • This paper presents the design and analysis of a vibration-driven electromagnetic energy harvester that uses a multi-pole magnet. The physical backgrounds of the vibration electromagnetic energy harvester are reported, and an ANSYS finite element analysis simulation has been used to determine the different alignments of the magnetic pole array with their flux lines and density. The basic working principles for a single and multi-pole magnet are illustrated and the proposed harvester has been presented in a schematic diagram. Mechanical parameters such as input frequency, maximum displacement, number of coil turns, and load resistance have been analyzed to obtain an optimized output power for the harvester through theoretical study. The paper reports a maximum of 1.005 mW of power with a load resistance of $1.9k{\Omega}$ for 5 magnets with 450 coil turns.

A Study on the Q-Factor Characteristics of Integrated Inductors Array (박막 인덕터 어레이의 Q-Factor 특성에 관한 연구)

  • Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2105-2107
    • /
    • 2004
  • In this study, Spiral inductors on the $SiO_2$/Si(100) substrate were fabricated by the magnetron sputtering method. Cu thin film with the thickness of 2 ${\mu}m$ was deposited on the substrate. Also we fabricated square inductors through the wet chemical etching technique. The inductors are completely specified by the turn width and the spacing between spirals. Both the width and spacing between spirals were varied from 10 to 60 ${\mu}m$ and from 20 to 70 ${\mu}m$, respectively. Inductance and Q factor dependent on the RF frequency were investigated to analyze performance of inductor arrays. Also, We recommend that the reasonable Q-factors, spec's turns and thickness of the coil for inductors cab be set to be ideal condition.

  • PDF

Development of Spectrometer with 1 GFLOPs Digital Signal Processors

  • 김휴정;정민영;김치영;고광혁;이상철;이흥규;안창범
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.178-178
    • /
    • 2001
  • 목적: 본 연구에서는 초당 $10^{9}$ 부동점 연산이 가능한 Texas Instrument사의 TMS320C6701 DSP를 이용하여 연속적으로 변하는 경사자계를 real-time으로 계산하여 후, 4 채널의 phase array 코일을 이용하여 영상을 얻은 후 빠른 재구성을 통하여 영상을 확인할 수 있는 spectrometer를 개발하였다. 대상 및 방법: 실시간 구현을 위하여 DSP 보드에 Texas Instruments(Tl)사의 TMS320C6701을 장착하였다. Transmitter, receiver, 그리고 gradient를 담당하는 DSP 보드들과 이들과 연결되어 rf modulation, gradient waveform을 만드는 analog board와 phased array coil을 위한 4 채널까지 측정이 가능한 receiver board로 구성하였다. Gradient 보드의 경우 각 경사자계의 채널(Gx, Gy, Gz)의 sampling points를 real-time으로 각각 계산함으로써 blipped-EPI 뿐만 아니라, 경사자계 파형이 연속적으로 변화하는 spiral-EPI의 실험도 가능하게 하였다.

  • PDF

Improved Center Array-Sequensing Phase Unwrapping(ICASPU) method for reconstruction of MR phase image (자기공명 위상영상 재구성을 위한 향상된 중심배열 정렬 위상 펼침 방법)

  • Han, Y.H.;Kim, K.S.;Jung, W.B.;Kim, Y.S.;Lee, S.H.;Jung, S.H.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.23-26
    • /
    • 2009
  • This study proposed an improved center array-sequencing phase unwrapping (ICASPU) algorithm. 2% agarose phantom dopped with 0.6mM/l MnCl2 was used with clinical 1.5T MRI system and commercial knee coil. Obtained k-space data(raw-data) was transmitted to PC and reconstructed into phase image with MATLAB software. Previous center array-sequence phase unwrapping algorithm wascompared with proposed ICASP algorithm using second order regression analysis. As a result, we found that the amount of error on proposed ICASPU method is less about 5 times than that of previous CASPU method. In this study, we exploit improved Center array-sequence phase unwrapping algorithm and expect to apply to images including phase informations.

  • PDF

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

GMR Sensor Applicability to Remote Field Eddy Current Defect Signal Detection in a Ferromagnetic Pipe (강자성 배관의 원격장 와전류 결함 신호 검출에 GMR Sensor의 적용성 연구)

  • Park, Jeong Won;Park, Jae Ha;Song, Sung Jin;Kim, Hak Joon;Kwon, Se Gon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.483-489
    • /
    • 2016
  • The typical methods used for inspecting ferromagnetic pipes include the ultrasonic testing (UT) contact method and the following non-contact methods: magnetic flux leakage (MFL), electromagnetic acoustic transducers (EMAT), and remote field eddy current testing (RFECT). Among these methods, the RFECT method has the advantage of being able to establish a system smaller than the diameter of a pipe. However, the method has several disadvantages as well, including different sensitivities and difficult-to-repair coil sensors which comprise its array system. Therefore, a giant magneto-resistance (GMR) sensor was applied to address these issues. The GMR sensor is small, easy to replace, and has uniform sensitivity. In this experiment, the GMR sensor was used to measure remote field and defect signal characteristics (in the axial and radial directions) in a ferromagnetic pipe. These characteristics were measured in an effort to investigate standard defects at changing depths within a pipe. The results show that the experiment successfully demonstrated the applicability of the GMR sensor to RFECT signal detection in ferromagnetic pipe.

Characteristic Analysis of Double sided Slotless Halbach Array Permanent Magnet Linear Generator with Three Phases Concentrated Winding of Cored Type by using Analytical Method (해석적 방법을 이용한 3상 집중권 권선을 갖는 양측식 슬롯리스 고정자 Halbach 배열 영구자석 선형 발전기의 특성해석)

  • Seo, Sung-Won;Choi, Jang-Young;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2015
  • This paper deals with the generating characteristic analysis of permanent magnet linear generator (PMLG) with double-sided Halbach magnet array mover and three phases concentrated stator windings by using analytical method. On the basis of a magnetic vector potential and Maxwell's equations, governing equations are obtained, and magnetization modeling for Halbach magnet array is performed analytically by using the Fourier series. And then, we obtain electrical parameters such as back-EMF constant, resistance, and coil inductance based on magnetic field calculations. Finally, analytical results for generating performance are confirmed by comparing with finite element analysis results.

Optimal design of a Linear Active Magnetic Bearing using Halbach magnet array for Magnetic levitation (자기부상용 Halbach 자석 배열을 이용한 선형 능동자기 베어링의 최적설계)

  • Lee, Hakjun;Ahn, Dahoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.792-800
    • /
    • 2021
  • This paper presents a new structure for a linear active magnetic bearing using a Halbach magnet array. The proposed magnetic bearing consisted of a Halbach magnet array, center magnet, and single coil. The proposed linear active magnetic bearing has a high dynamic force compared to the previous study. The high dynamic force could be obtained by varying the thickness of a horizontally magnetized magnet. The new structure of Halbach linear active magnetic bearing has a high dynamic force. Therefore, the proposed linear active magnetic bearing increased the bandwidth of the system. Magnetic modeling and optimal design of the new structure of the Halbach linear active magnetic bearing were performed. The optimal design was executed on the geometric parameters of the proposed linear active magnetic bearing using Sequential Quadratic Programming. The proposed linear active magnetic bearing had a static force of 45.06 N and a Lorentz force constant of 19.54 N/A, which is higher than previous research.

Sensor Calibration of a Helmet MEG System (헬멧형 뇌자도 장치의 센서 교정)

  • Kwon, H.;Kim, K.;Yu, K.K.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.