• Title/Summary/Keyword: coaxial

Search Result 1,000, Processing Time 0.031 seconds

A Study on Design of Microstrip Patch Antenna for Mobile Communication Systems using IE3D (IE3D를 이용한 단일 급전 이동통신용 마이크로스트립 패치 안테나 설계에 관한 연구)

  • Park, Jong-Dae;Park, Byeong-Ho;Shim, Woo-Seop;Kim, Myeong-Dong;Seong, Hyeon-Kyeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.316-319
    • /
    • 2012
  • In this paper, a novel particle swarm optimization method based on IE3D is used to design a mobile communication Microstrip Patch Antenna. The aim of the thesis is to Design and fabricate an inset fed rectangular Microstrip Antenna and study the effect of antenna dimensions Length (L), Width (W) and substrate parameters relative Dielectric constant (${\varepsilon}r$), substrate thickness on Radiation parameters of Band width. When the antenna was designed, a dual-band, dual-polarized antenna was used to secure the bandwidth and improve performance, and a coaxial probe feeding method so that the phased array of antenna is easy.

  • PDF

Implementation of Line Scan Camera based Training Equipment for Technical Training of Automated Visual Inspection System (자동 시각 검사 시스템 기술훈련을 위한 라인스캔 카메라 기반의 실습장비 제작)

  • Ko, Jin-Seok;Mu, Xiang-Bin;Rheem, Jae-Yeol
    • Journal of Practical Engineering Education
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • The automated visual inspection system (machine vision system) for quality assurance is important factory automation equipment in the manufacturing industries, such as display, semiconductor, etc. There is a lot of demand for the machine vision engineers. However, there are no technical training courses for machine vision technologies in vocational schools, colleges and universities. In this paper, we present the implementation of line scan camera based equipment for technical training of the automated visual inspection system. The training system consists of the X-Y stage which is widely used in machine vision industries and its variable image resolution are set to $10-30{\mu}m$. Additionally, this training system can attach the industrial illumination, either the direct illuminator or coaxial illuminator, for verifying the effect of illuminations. This means that the trainee can have a practical training in various equipment conditions and the training system is similar to the automated visual inspection system in industries.

Design and Implementation of the Combline Bandpass Filter for the Satellite Transponder using Least-squares Curve-fitting Method (Least-squares Curve-fitting 방법을 이용한 위성중계기용 Combline 대역통과여파기의 설계 및 제작)

  • 정근욱;이재현;박광량;김재명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.8
    • /
    • pp.1485-1492
    • /
    • 1994
  • In this paper, we design and implement the Combline Bandpass Filters for the satellite transponder by using the least-squares curve-fitting method. The Combline Bandpass Filters are located front of the mixer and behind of it, which is the component of down converter. Comparing with the filters which have $\lambda$/4 resonance length. Combline Filter has wide range of stop-band by using $\lambda$/8. So, it is useful to the satellite transponder owing to its low mass and small size. The filters described are realized as coupled rectangular coaxial transmission lines. The choice of this type is due to the ease of machining and wide variations in coupling coefficients rather than the use of the round rod resonators. We determine 800 MHz bandwidths for the combline bandpass filters. By using Chebyshev filter function, we design and implement 4-pole combline filters.

  • PDF

A Study on the Exhaust Gas Recirculation in a MILD Combustion Furnace by Using the Coanda Nozzle Effect (MILD 연소로에서 Coanda 노즐 효과를 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.967-972
    • /
    • 2013
  • A MILD (Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow rate of hot exhaust gas to the combustion furnace. The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of coanda nozzle geometrical parameters, nozzle passage gap length, nozzle passage length, nozzle angle and expansion length. The optimal configuration of coanda nozzle for the best entrainment flow rate was gap length, 0.5 mm, expansion angle, 4o and expansion length, 146 mm. The nozzle passage length was irrelevant to the exhaust gas entrainement.

Input Impedance Calculation of the Power Line Communication System (전력선 통신 시스템의 입력 임피던스 계산)

  • Chun, Dong-wan;Lee, Jin-taek;Park, Young-Jin;Kim, Kwan-Ho;Shin, Chull-Chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.983-990
    • /
    • 2004
  • In this paper, we calculated the input impedance of the power line communication(PLC) networks using medium voltage power line. First of all, we proposed input and output teoninal model of PLC network, and calculated the input impedance applying the attenuation constants by radiation loss, conductor loss, dielectric loss. From the calculation result, we knew that the attenuation by radiation loss was largest, and the input impedance appears like a standing wave fonn with a fixed cycle because the high reflection at the input terminal for the characteristic impedance of the power line is very large. And also the cycle of input impedance depends on the coaxial cable length, and the amplitude depends on the characteristic impedance of power line and losses. From the measurement result, calculated result was very similar to the measured result.

Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan (2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구)

  • Cho, Jin-Soo;Cho, Lee-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

A study on the Application of Non Prism Totalstation to Facility Survey (시설물측량에서의 무프리즘 토털스테이션 활용성 연구)

  • 박경식;이현직;함창학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.2
    • /
    • pp.155-164
    • /
    • 2003
  • The entrance of non prism totalstation brought the application possibility to many fields including a topographic survey and a facility measurement. In this research we would try to examine the errors and the problems which will be happened in measuring object with non prism totalstation and to evaluate the accuracy and applicability. For this purposes, We checked accuracy change according to the observation ang1e and material of the object, and analyzed how much accuracy was effected with the color of the object surface and laser divergency which is proportional to the distance. By measuring the facility practically and analyzing it's results, We evaluated possibility of practical use of a non prism totalstation for a facility measurement. Consequently, We propose that the observation accuracy of non prism totalstation is not depend on the hardness or material of the object and can get a good result only when we use non prism totalstation with coaxial focusing system for a facility survey.

Relative Timing of Shear Zone Formation and Granite Emplacement in the Yechon Shear Zone, Korea (예천(醴泉) 전단대(剪斷帶)의 생성(生成)과 화강암(花崗岩) 관입(貫入)의 상대적(相對的)인 시기(時期))

  • Chang, Tae Woo
    • Economic and Environmental Geology
    • /
    • v.23 no.4
    • /
    • pp.453-463
    • /
    • 1990
  • The Yechon shear zone developed by strike-slip movement was formed in a relatively high temperature condition just after the Jurassic syntectonic granites had been emplaced during Daebo Orogeny. Post-emplacement formation of the shear zone is favored by continuity of foliations and lineations within and without the granites, development of mylonitic structures in the wallrocks, deformation of pegmatite and felsite dikes, and pretectonic growth of porphyroblasts in the wallrocks. A variety of shear sense indicators in the shear zone are predominantly observed in the intensely to extremely deformed rocks. They show that bulk non-coaxial detormation has occurred, and that the sense of shear is consistently dextral with S-C fabrics, grain shape fabrics, asymmetric porphyroclast systems, mica fish, asymmetric extension structures and quartz C-axis fabrics.

  • PDF

Effect of Injector Cooling on Ignition of Cryogenic Spray (분사기 냉각이 초저온 분무의 점화에 미치는 영향)

  • Kim, Do-Hun;Lee, Jin-Hyuk;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.222-229
    • /
    • 2012
  • The cooling of a injector effects on the vapor pressure of cryogenic oxidizer spray, and it decides the phase transition point at the ignition process, when the combustion chamber pressure increases drastically. The phase transition of oxidizer spray affects the ignition characteristics, and several ignition tests with the LOx/$GCH_4$ uni-element coaxial swirl injector was performed in the different initial temperatures of oxidizer injector, in order to investigate the effect of injector cooling on the ignition transient characteristics. At the transition point of oxidizer phase, where the combustion chamber pressure increased over the LOx vapor pressure, the temporary quenching phenomenon of the flame occurred. The lower temperature of chilled down injector and tubing tends to move up the phase transition earlier.