• 제목/요약/키워드: coaxial

Search Result 1,000, Processing Time 0.031 seconds

A Study on the Errors for the Improved Version of the Virtual Transmission-Line Model (개선된 가상의 전송선로 모델의 오차 연구)

  • 조유선;김세윤;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.971-981
    • /
    • 2002
  • An open-ended coaxial probe method has been considered as one of effective tools for measuring electrical properties of its contacted material without shaping and fitting. The measured reflection coefficient at the probe's end is able to convert into the corresponding complex permittivity by employing the improved version of virtual transmission-line model Presented by our lab already. But the error of complex permittivity converted by equivalent model increases as the operating frequency ascends high. The errors of complex permittivity in the open-ended coaxial probe can be yielded compositively by the imperfect contact or probe, manufacture error of probe and complex permittivity error of reference material etc. Therefore it is necessary to limit the problem to identify the error causes in high frequency. In this paper, the errors which are resulted from the measurement of reflection coefficient are removed by using the FDTD(Finite-Difference Time-Domain) method, the error causes are limited the conversion model problem. And the error study of the improved conversion model is performed from several viewpoints. At first, the local minimum of parameter to be calculated by the iteration method in the conversion model is checked. At second, the modeling of the equivalent model is checked in the frequency range. From this study, we know the valid range of the improved conversion model.

A Study of Dual-Frequency Microstrip Patch Antenna (이중공진 마이크로스트립 패치 안테나에 관한 연구)

  • 장준영;김준모;윤영중;엄순영;전순익
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.515-525
    • /
    • 1998
  • In this paper, for both transmission and reception with single antenna system of satellite communication, dual-frequency antennas which operate simultaneously at 12.5 GHz and at 14.25 GHz are designed, constructed and measured. Also by using dual feeding structure, the problems of single-fed dual-frequency antenna such as the separation of transmitting and receiving signals and single polarization, are solved. Microstrip patch as a radiation element of dual-fed dual-frequency antenna has width and length which are the resonance lengths of the corresponding frequencies for transmission and reception, respectively. The effects of the feed line on the other frequency feeding are minimized with the optimal matching scheme for the feed lines. For solving the space problems of dual-fed two-dimensional array antennas, microstrip-line and coaxial probe feedings are used for each frequency and a two-dimensional $2\times2$ array antenna was designed and measured their characteristics. The experimental results show that errors of resonance frequencies are less than 1.44%, the return losses are less than -21 dB and the isolations between two feeding ports are less than -21 dB. The characteristics of radiation patterns of dual frequency microstrip antenna are measured and evaluated. The directivities, sidelobe levels and cross polarizations are also measured and compared with the simulations. The results show some errors due to the misalignment of coaxial probe feeding.

  • PDF

Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition (난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.116-123
    • /
    • 2008
  • In order to study the heat transfer, effectiveness and pressure drop of an internal heat exchanger (IHX) for $CO_2$, heat pump under heating condition, the experiment and numerical analysis were performed. Four kinds of IHXs were used. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of IHX on the flow rate of refrigerant, the IHX length, the operating condition of a gas-cooler and an evaporator and the type of IHXs were investigated. With increasing the flow rate, the heat transfer rate increased about 25%. The heat transfer of the micro-channel tube was larger about 100% than that of the coaxial tube. With increasing the IHX length, the heat transfer rate decreased. The low-side pressure drop was larger compared with that of the high-side. And the pressure drop of the microchannel tube was larger about 100% than that of the coaxial tube. With increasing the high-side temperature and decreasing the low-side temperature, the heat transfer rate increased about 3%. From this study, we can see that new correlation on $CO_2$ heat transfer characteristics and tube type is necessary.

Results of Cold Flow Test and Design of Injectors for Oxidizer-rich Preburner (산화제 과잉 예연소기용 분사기 설계 및 수류 시험 결과)

  • So, YoonSeok;Woo, SeongPil;Lee, Kwang-Jin;Yu, ByungIl;Kim, Jinhyung;Cho, Hwangrae;Bang, Jeongsuk;Han, YeongMin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.52-57
    • /
    • 2018
  • This paper presents the design and cold flow test results of oxidizer-rich preburner injectors for a 9 tonf-class staged combustion engine cycle. Three types of coaxial swirl injectors were designed, and 12 injectors were designed for each type. The diameters of the fuel tangential holes are identical. The diameters of the oxidizer tangential holes were varied to investigate the influence of combustion in the oxidizer-rich preburner according to the momentum ratio of the gas oxidizer generated from combustion in the injector chamber and liquid oxidizer through the cooling channel. It will be verified through a powerpack and combustion test using an oxidizer-rich preburner. In the cold flow test, the fuel flow rate and oxidizer tangential hole flow rate reached the target value based on the designed differential pressure.

Wideband 6-port Phase Correlator Using Caxial Cable Impedance Transformer and Wireline Coupler (동축선 임피던스 변환기와 Wireline Coupler를 이용한 광대역 6-단자 위상 상관기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1188-1195
    • /
    • 2022
  • The 6-port phase correlator consists of one in-phase power divider and three 3-dB 90-degree phase difference power dividers, and is mainly used in a demodulation circuit that determines the phase of an input signal. This paper proposes the wideband 6-port phase correlator that consists of an in-phase power divider using a wideband 2:1 impedance transformer with three 37.5-Ω coaxial cables, and a 3-dB 90-degree phase difference power divide using Wireline. The proposed wideband phase correlator fabricated at a center frequency of 1000MHz has the value of the input reflection coefficient(S11 and S22) -14dB or less in the frequency range of 640~1270MHz. Also, the signal transmission characteristic(Si1), from the in-phase power divider input port to four output ports, has the amplitude of -6.5±0.6dB and the phase error of within ±3.4°, and the signal transmission characteristic(Si2), from the 90 degree phase difference power divider input port to four output ports, has the amplitude of -6.1±0.6dB and the phase error of within ±6.2°.

Design and fabrication of a RFID Reader Antenna in 900MHz Band (900MHz 대역 RFID 리더기 안테나 설계 및 제작)

  • Kim, Chan-Baek;Park, Seong-Il;Ko, Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.125-128
    • /
    • 2008
  • In this paper, a stand-type planar antenna of 900MHz RFID band is designed and fabricated. As the proposed antenna is stand-type use of air permittivity, Bandwidth used ground height at rectangle patch structure and coaxial feed line is widen. Also wideband width can solve problem that RFID tag attached to things happens frequency shift keying phenomenon by liquid, special metal, temperature, humidity etc. Bandwidth of fabricated antenna to VSWR less than 2 is satisfied 11.9% at $890MHz{\sim}1000MHz$. And proposed antenna is circular polarization antenna of operating characteristics that axial ratio is less than 2 and gain is 6dBi.

  • PDF

Ozone Generation Characteristics in Dielectric Barrier Discharge (유전체 장벽 방전내에서 오존발생 특성)

  • Lee, Hyeong-Ho;Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

Electrical Properties of Transformer Oils (II) (변압기유의 전기적인 특성 (II))

  • Lee, Yong-Woo;Cho, Don-Chan;Shin, Man-Seob;Lee, Soo-Won;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1123-1125
    • /
    • 1995
  • In order to investigate the electrical properties for transformer oils, the dielectric properties and volume resistivity were made researches. To measure the characteristics of dielectric liquid, volume resistivity and dielectric loss, coaxial cylindrical liquid electrode was used, geometric capacitance was confirmed to 16[pF]. Highmegohm meter of VMG-1000 was used for measuring volume resistivity, the appling voltages were DC 100, 250, 500[V] in the temperature range of $20{\sim}100[^{\circ}C]$. Experiments for measuring the dielectric loss were performed at $20{\sim}120[^{\circ}C]$ in temperature range, $30{\sim}1.5{\times}10^5$[Hz] in frequency range and $300{\sim}1500$[mV] in voltage range and then, the result of experiment for the movement of carrier and the physical constants to contribute dielectric properties is introduced.

  • PDF

Optimized Design of T-Shaped Microstrip Antenna with Various Dimensions (T형 마이크로스트립 안테나의 면적 비에 따른 최적 설계)

  • Kim, Jin-Bok;Lee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.5
    • /
    • pp.53-59
    • /
    • 2010
  • There are various types of antenna fed method; coaxial probe, coupling, parasitic elements, and impedance matching. In this paper, the fed method of the proposed antenna is microstrip line type. The high frequency structure simulator (HFSS) is used to analyze the characteristics of the T-shaped microstrip antenna with various patch dimensions. In comparison with the basic microstrip antenna, this proposed T-shaped microstrip antenna with 40.38 % of patch dimensions has the optimum characteristics of resonant frequency, return loss, and radiation pattern at 2.0 GHz band.

Design and Realization UHF Power Amplifier for Air Traffic Control (항공교통관제용 UHF대역 전력 증폭기 설계 및 구현)

  • Kang, Suk-Youb;Song, Byoung-Jin;Park, Wook-Ki;Go, Min-Ho;Park, Hyo-Dal
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.167-172
    • /
    • 2006
  • In this paper, the 25W power amplifier for UHF band radio transceiver has been designed and realized. The power amplifier was composed of drive, power amplifier and control stages. Feedback topology and coaxial line baluns were used for wide band operation. The VDMOS, which has reliable performance for linearity and efficiency, was used for power device and designed to operate as push-pull amplification at Class AB Bias. The power amplifier designed in such a way was found to show stable AM modulation performance when voice signal was detected at the gate stage, with being designed and realized to meet output specifications of commercial air traffic control transmitter.

  • PDF