• Title/Summary/Keyword: coaxial

Search Result 1,005, Processing Time 0.032 seconds

Analysis of Local Distribution of Illuminating Angles for Designing Illuminators of Automated Optical Inspector (자동 광검사 장비용 조명광학계 설계를 위한 국부적인 조명각 분포의 분석)

  • Kim, Seung-Yong;Jeong, Sang-Cheol;Kim, Dae-Chan;Ju, Dong-Ik;Choe, Tae-Il;Lee, Baek-Gyu;O, Beom-Hwan;Lee, Seung-Geol
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.300-301
    • /
    • 2009
  • In order to design a special illuminator required for an automated optical inspection system, distributions of illuminating angles and intensities of illuminating rays incident on a specimen surface are taken into consideration. This methodology is tried to optimize coaxial illuminating systems by using the specially-coded program.

  • PDF

Generation of Full Poincaré Beams on Arbitrary Order Poincaré Sphere

  • Wang, Jue;Wang, Lin;Xin, Yu
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.631-636
    • /
    • 2017
  • We firstly develop a straightforward method to generate full $Poincar{\acute{e}}$ beams with any polarization geometry over an arbitrary order $Poincar{\acute{e}}$ sphere. We implement this by coaxial superposition of two orthogonal circular polarized beams with alternative topological charges with the help of a Mach-Zehnder interferometer. Secondly we find the existence of singularity points. And the inner relationship between their characteristics and the order of $Poincar{\acute{e}}$ spheres is also studied. In summary, this work provides a convenient and effective way to generate vector beams and to control their polarization states.

Folded Monopole Antenna Using the Rectangular Patch for Multi-band Wireless USB Dongle Applications (다중대역 무선 USB 동글 장치를 위한 사각 패치를 이용한 폴디드 모노폴 안테나)

  • Lee, Yun Min;Lee, Jae Choon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.2
    • /
    • pp.11-15
    • /
    • 2013
  • We in order to use WLAN communication device planned wireless USB dongle internal antenna of 2.4 GHz/5.8 GHz band. So it uses square patch dual-wideband and quality is satisfactory and it designed print folded monopole antenna of the shape which is simple. The thickness of the antenna was fed by a $50{\Omega}$ coaxial cable feeding 1mm dielectric constant 4.4 FR4 substrate was used. The overall size of the antenna is $20mm{\times}50mm$. So the internal antenna is suitable. Measurement results of the fabricated antenna, the return loss of more than 10 dB in the two bands could be obtained. Radiation pattern has a maximum gain of 3.75 dBi value.

ACCELEROMETER SELECTION CONSIDERATIONS Charge and Integral Electronic Piezo Electric

  • Lally, Jim
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.1047-1051
    • /
    • 2004
  • Charge amplifier systems benefit from the very wide dynamic range of PE accelerometers by offering flexibility in adjusting the electrical output characteristics such as sensitivity and range. They are well suited for operation at high temperatures. Modern charge systems feature improved low noise operation, simplified digital controls, and dual mode operation for operation with charge or IEPE voltage mode sensors. high impedance circuitry is not well suited for operation in adverse field or factory environments. The resolution of a PE accelerometer may not be specified or known since noise is a system consideration determined by cable length and amplifier gain. IEPE accelerometrs operate from a constant current power source, provide a high-voltage, low-impedance, fixed mV/g output. They operate through long, ordinary, coaxial cable in adverse environments without degradation of signal quality. They have limited high temperature range. IEPE sensors are simple to operate. Both resolution and operating range are defined specifications. Cost perchannel is lower compared to PE systems since low-noise cable and charge amplifiers are not required.

  • PDF

Arterial Complication of Percutaneous Transluminal Angioplasty - A Report of Case - (경피 경관 혈관 성형술후 발생한 동맥내 합병증의 치험 1례)

  • 김상익
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1273-1277
    • /
    • 1992
  • Percutaneous Transluminal Angioplasty[PTA] was introduced by Dotter and JudKins [1964], using coaxial catheters of increasing diameter. The remarkable advances in vascular catheter technology over the past several decades have permitted the development. But the application of the balloon catheters carries with it the risk of arterial injury, thrombosis, embolism, and loss of life or limb. A 53-year-old man was admitted to other hospital due to a intermittent claudication in his right leg for 10 years. and PTA was performed at that hospital. Thereafter he was transferred to our hospital because of coldness, pulselessness, rest pain, ischemic ulcer, and progressing gangrene at the anterior aspect of left lower leg. The left lower extremity was salvaged by left ilio-femoral bypass and later saphenous in situ femoro-popliteal bypass.

  • PDF

Rheological Properties of Cement Pastes Blended Finex-Slag Powder (파이넥스 슬래그 미분말을 혼합한 시멘트 페이스트의 유동특성)

  • Lee, Keun-Jae;Byun, Seung-Ho;Song, Jong-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.657-661
    • /
    • 2009
  • In this study, rheological properties of cement pastes containing ground Finex-slag (4000, 6000, 7000 c$m^2$/g) were investigated bymini-flow test and coaxial cylinder viscometer. And also blast furnace slag(4000, 6000, 7000 c$m^2$/g) were used for comparison. According to the experimental results, Finex-slag and blast furnace slag showed very similar trend in the rheological properties of the cement pastes. The fluidity of cement pastes blended Finex-slag and blast furnace slag powder were improved by high replacement ratio. In the relationship of plastic viscosity and yield stress appeared the tendency of the proportion greatly. And in the relationship of plastic viscosity, yield stress and mini-flow appeared the tendency of the inverse proportion.

Development of Inspection System for the IC package (반도체 패키지 외관 검사 시스템 개발)

  • Lee, Jung-Seob;Kwon, Oh-Min;Joo, Hyo-Nam;Kim, Joon-Sik;Rew, Keun-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.453-461
    • /
    • 2008
  • In this paper, new inspection method is proposed for the surfaces of lead frame and IC's. Optimal optical system and the accurate algorithm for the surface inspection are needed in machine vision area. The proposed optical system is composed of rectangular oblique light illumination and coaxial light illumination for the higher contrast and the results shows the better performances through experiments. The markings of IC surface are inspected using the accurate proposed method using the partitioned correlation coefficient, and the result shows reduction of under kill ratio compared to the previous method.

A Study on the construction of Broad-Band Twisted-Wire Quadrature Hybrid (광대역 Twisted-Wire Quadrature Hybrid 회로구성에 관한 연구)

  • 박정기;김성진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.78-85
    • /
    • 1980
  • A symmetrical 3-dB quadrature hybrid circuits, consisting mainly of bifilar pair of taitoted wires, is described. A cascade of two such hybrid circuits can achieve an octave bandwidth hybrid circuit with a small coupling loss. Since the proposed type is simple, compact, and low In cost 1 its applicarion may be preferred to the more common coaxial line or printed -circuit type hybrid version in the frequency region below 1 GHz. This study provides a design method for a hybrid circuit mixing two different antenna signals for the anti - ghosting of television signal.

  • PDF

Modified Monopole Antenna for Microwave Thermal Therapy (마이크로파 에너지를 이용한 열 치료용 링-모노폴 안테나)

  • 문명호;곽상태
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.86-90
    • /
    • 2001
  • Modified coaxial-slot antenna for minimally invasive microwave thermal therapy for liver tumor is studied in this paper. Minimally invasive microwave antenna in medicine are applied for hyperthermia for medical treatment for cancer, cardiac catheter ablation for ventricular arrhythmias treatments, microwave treatment of Benign prostatic hypertrophy, and so on. Microwave hyperthermal ablation for liver tumors is expected for enthusiasts as an alternative to curative surgical resection. Tumors have to heated up to 60 degree C to coagulate .cancer cells but less than 100 degree C to avoid evaporation. Temperature dependence of properties of the tissues should be considered for wide range of treatment. Electrical properties of liver tissue were measured for different temperatures. SAR distribution around the antenna into the liver are simulated using Remcom's XFDTD.

  • PDF