• 제목/요약/키워드: coaxial

검색결과 1,000건 처리시간 0.028초

A Square Coaxial Transmission Line with a Thin-Wire Inner Conductor to Measure the Absorbing Performance of Electromagnetic Absorbers

  • Kang, Tae-Weon;John Paul;John Paul
    • Journal of electromagnetic engineering and science
    • /
    • 제4권1호
    • /
    • pp.43-49
    • /
    • 2004
  • A low-frequency coaxial reflectometer(LCR) with a thin-wire inner conductor is designed and constructed to measure nondestructively the absorbing performance of electromagnetic absorbers in the frequency range of 10 MHz to 200 MHz. The LCR consists of a square coaxial transmission line and a network analyzer with a time-domain measurement capability. Inherent characteristics of a square coaxial line with a thin-wire inner conductor which deteriorate the impedance matching of the input port of the LCR are addressed. And the characteristics are improved by employing a multiwire inner conductor. Measured and calculated reflection losses of a flat ferrite tile absorber are presented.

대전류 측정용 Tubular Coaxial Shunt 특성에 관한 연구 (The Study of Characteristics of Tubular Type Coaxial Shunt for High Current Measuring System)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.834-836
    • /
    • 2003
  • This paper describes the optimal design, construction and performance evaluation of coaxial shunts used in high current testing laboratory for current measuring system. These shunts, which are of tubular type coaxial shunts, the currents to be measured range from Amperes to several kiloAmperes, and the frequency of the signals has a bandwidth from DC to megaHertz. The shunt must have the mechanical strength to support the forces produced by the transient current, above all, the measuring capabilities of shunt are dependent upon short response time and it must be as free as possible of inductive effects. In this paper presents both characteristic of shunt and design of tubular type coaxial shunt.

  • PDF

레이저를 이용한 의료기기용 미세 동축케이블의 실드선 탈피 (Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Laser)

  • 이정완;김정훈
    • 한국정밀공학회지
    • /
    • 제26권9호
    • /
    • pp.64-71
    • /
    • 2009
  • Recently as ultrasonic medical devices are gradually developed, many of those require smaller and more precision coaxial cables in the probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper we use the Nd:YAG laser for the efficient striping of conduct wire of cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, we propose a pre-process of the cable before stripping in order to enhance the performance.

2차원 유한요소 해석을 이용한 고속용 마그네틱 기어의 형상에 따른 특성 해석 (Characteristic Analysis of High Speed Coaxial Magnetic Gear by Two-Dimensional Finite Element Analysis)

  • 이정인;신경훈;방태경;이상화;최장영
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.36-43
    • /
    • 2019
  • In this paper, the characteristics of the coaxial magnetic gear according to the shape of the same gear ratio are analyzed using the two - dimensional finite element analysis. The rotor shape is SMCMG, CPCMG and RCMG. After this we analyzed the characteristics according to three shapes. Also, the amount of permanent magnet used in each shape was compared. Next, characteristics analysis of the magnetic gear according to the shape at the same torque was performed. And the total weight and efficiency of the magnetic gears were compared and verified.

물방울 감지 센서의 제작에 관한 연구 (A Study on the Manufacture of the Water Sensor)

  • 김진국;이윤민
    • 디지털산업정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.37-45
    • /
    • 2014
  • This paper is a study of the water sensor using a coaxial cavity resonator. This water sensor uses the resonant frequency variation of the coaxial cavity resonator when there is a water drop of the used coaxial cavity resonator. And we made resonant frequencies by controlling the input voltage of the oscillator which will be mainly resonated in the coaxial cavity resonator. First, we made the coaxial cavity resonator by simulating the resonator structure with the proposed size and we expect the resonant frequency from the simulation and then we decide the VCO from the result. Second, we made the water drop detecting sensor circuit and measured the water sensor. We decided the size of the resonator as inner conductor 5mm, outer conductor 14mm, the height of resonator 9.5mm, and the height of the glass 6mm from the simulated result. The simulated resonant frequencies are 3.09GHz and we made the VCO frequency ranges from 2.56GHz to 3.2GHz. The measured resonant frequency is 2.97GHz and the return loss is under -8. 4 dB at the center frequency. When the water is dropped on the glass of the resonator, the voltage has changed from 690mV to 145mV. It shows the proposed water sensor can detect the water by the resonant frequency variation of the resonator.

이중 대역 소형 동축 도파관 급전 혼 설계 (Design of a Compact Coaxial Waveguide Feed Horn for Dual Band)

  • 윤소현;엄만석;염인복
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.109-113
    • /
    • 2015
  • 본 논문은 초점 반사판 안테나를 위한 이중 대역 급전 혼에 대한 연구 결과를 제시하였다. 반사판 안테나의 초점에 위치하는 급전혼에 의한 전파 장애를 최소화하기 위해 동축 도파관 구조를 적용하였다. 동축 도파관의 내부 영역은 높은 주파수 대역을 위한 원형 도파관 TE11 모드가 여기 되도록 하였다. 외부 영역은 낮은 주파수 대역을 위해 사용되고, 동축 TE11 모드는 진행하고 기본 TEM 모드는 억제되도록 설계하였다. 각각의 여기 모드 생성을 위해서는 구조적 제약이 따르고, 이는 반사 손실 및 패턴 성능을 저하시킨다. 본 논문은 용량성 및 유도성 아이리스를 사용하여 반사 손실을 개선하였다. 또한 이중 모드에 의한 개선된 패턴 성능을 보였다. 본 논문에서 제시한 혼 설계는 제작 및 시험을 통해 성능을 검증하였다.

핀라인-마이크로스트립 변환을 이용한 동축선로 도파관 형태의 공간 결합기 (A Coaxial Waveguide-based Spatial Combiner Using Finline-to-Microstrip Transitions)

  • 김보기;이수현;김형종;신석우;김상훈;김재덕;최진주;김선주
    • 한국ITS학회 논문지
    • /
    • 제10권5호
    • /
    • pp.79-86
    • /
    • 2011
  • 본 논문에서는 S-대역에서 동작하는 동축선로 도파관 형태의 공간 결합기 구조를 제안하였다. 제안된 결합기는 동축 선로 도파관, 임피던스 변환기, 핀라인-마이크로스트립 변환기로 구성되어 있다. 동축선로 도파관은 구형 도파관과는 달리 균일한 전자기장 분포를 얻을 수가 있기 때문에 전력을 균일하게 공급할 수 있는 장점을 가진다. 핀라인-마이크로스트립 변환기는 Antipodal 안테나를 이용하여 설계 하였으며, 소반사(small reflection) 이론을 적용하여 낮은 반사계수를 얻었다. Back-to-back으로 연결된 공간 결합기를 측정한 결과 최대 95%의 결합 효율을 얻었다.

적외선 카메라를 이용한 초음속 충돌 동축제트의 벽면 온도 측정 (An Experimental Study of the Wall Temperature of the Supersonic Impinging Coaxial Jet Using an FLIR)

  • 곽종호;;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1631-1636
    • /
    • 2004
  • The supersonic impinging jet has been extensively applied to rocket launching system, gas jet cutting control, gas turbine blade cooling, etc. In such applications, wall temperature of an object on which supersonic jet impinges is a very important factor to determine the performance and life of the device. However, wall temperature data of supersonic impinging jets are not enough to data. The present study describes an experimental work to measure the wall temperatures of a vertical flat plate on which supersonic, dual, coaxial jet impinges. An Infrared camera is employed to measure the wall temperature distribution on the impinging plate. The pressure ratio of the jet is varied to obtain the supersonic jets in the range of over-expanded to moderately under-expanded conditions at the exit of coaxial nozzle. The distance between the coaxial nozzle and the flat plate was also varied. The coaxial jet flows are visualized using a Shadow optical method. The results show that the wall temperature distribution of the impinging plate is strongly dependent on the jet pressure ratio and the distance between the nozzle and plate.

  • PDF

동축 마그네틱 기어의 고 기어비 적용을 위한 다중 기어 조합분석 (Multi-gear Combination Analysis for High Gear Ratio of Coaxial Magnetic Gear)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.355-362
    • /
    • 2021
  • 동축 마그네틱 기어는 비접촉 동력전달을 사용하기 때문에 기존 기계식 기어의 동력전달과정에서 발생하는 마찰, 마모, 소음, 발열을 최소화할 수 있다. 현재 다양한 산업에 적용하기 위한 연구가 활발히 진행되고 있으나 동축 마그네틱 기어가 갖는 특징 중, 높은 기어비에서 토크밀도가 급격히 감소하는 문제가 거론되었다. 본 논문은 높은 토크밀도를 갖는 저 기어비 동축 마그네틱 기어를 이용하여, 이들을 다중으로 결합하는 방향을 제시하였다. 해당 방법의 유효성을 확인하기 위해 단일형태의 고 기어비 모델과 토크밀도를 비교하고 다중 동축 마그네틱 기어의 기어비 조합을 분석함으로써 가장 우수한 조합을 선정하는 설계 방향을 나타내었다.

초음속 환형동축 자유 제트유동에 관한 실험적 연구 (보조제트 압력비 영향에 관하여) (The Experimental Study of Supersonic, Dual, Coaxial, Free, Jets (The effects of the assistant jet pressure ratio))

  • 이권희;이준희;김희동
    • 한국추진공학회지
    • /
    • 제5권2호
    • /
    • pp.51-58
    • /
    • 2001
  • 본 연구에서는 이중동축노즐로부터 대기로 방출되는 초음속 자유제트유동을 실험하였다. 출구마하 수가 2.0이고 충돌각이 다른 축소확대노즐 및 출구마하수가 1.0이고 충돌각이 다른 축소노즐을 사용하고, 주제트 압력비와 보조제트 압력비를 각자 4.0∼10.0, 1.0∼4.0으로 변화시켜 가면서 자유제트 유동장 특성을 조사하였다. 본 연구의 결과로부터 보조제트 압력비가 동축자유제트유동 특성에 영향을 미치며, 주제트 및 보조제트 압력비가 증가할수록 동축제트의 초음속 길이도 증가한다는 것을 알았다.

  • PDF