An Experimental Study of the Wall Temperature of the Supersonic Impinging Coaxial Jet Using an FLIR

적외선 카메라를 이용한 초음속 충돌 동축제트의 벽면 온도 측정

  • 곽종호 (안동대학교 기계공학과 대학원) ;
  • ;
  • 김희동 (안동대학교 기계공학부)
  • Published : 2004.04.28

Abstract

The supersonic impinging jet has been extensively applied to rocket launching system, gas jet cutting control, gas turbine blade cooling, etc. In such applications, wall temperature of an object on which supersonic jet impinges is a very important factor to determine the performance and life of the device. However, wall temperature data of supersonic impinging jets are not enough to data. The present study describes an experimental work to measure the wall temperatures of a vertical flat plate on which supersonic, dual, coaxial jet impinges. An Infrared camera is employed to measure the wall temperature distribution on the impinging plate. The pressure ratio of the jet is varied to obtain the supersonic jets in the range of over-expanded to moderately under-expanded conditions at the exit of coaxial nozzle. The distance between the coaxial nozzle and the flat plate was also varied. The coaxial jet flows are visualized using a Shadow optical method. The results show that the wall temperature distribution of the impinging plate is strongly dependent on the jet pressure ratio and the distance between the nozzle and plate.

Keywords