• Title/Summary/Keyword: coaxial

Search Result 1,005, Processing Time 0.031 seconds

Improvement of Power Capability and Field Uniformity with Tapered Coaxial Matching Units in Strip Line for Measuring Electromagnetic Immunity of Vehicular Components

  • Chung, Yeon-Choon;Kang, Tae-Won;Park, Dong-Chul
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.60-64
    • /
    • 1997
  • The design process and construction method of a strip line is described for measuring radiated susceptibility of vehicular components having electrical cables more than 2 min length. he characteristic impedance of the trip line was determined 90$\Omega$ to obtain the field uniformity of $\leq$${\pm}$3 dB in the frequency range from 100 kHz to 500 MHz. Tapered coaxial lines were used instead of the traditional lumped circuit element for the impedence matching units, therefore, the strip line has high power capability. Using these techniques, the field uniformity and power capability of a strip line could be considerably improved.

  • PDF

Uncertainty in the Calibration of Coaxal Thermal Noise Sources using a Noise Figure Measuring Equipment

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 2004
  • In this paper, the uncertainty in the calibration of coaxial thermal noise sources using a noise figure measuring (NFM) equipment is evaluated. Contributions to the uncertainty such as the calibration uncertainty of the standard noise source, mismatch, measurement of adapter efficiency, ambient temperature variation, and repeatability are evaluated in the frequency range of 10 MHz to 18 ㎓. Results show that the expanded uncertainty(k=2) is 0.23 ㏈ for the noise sources of 5 ㏈ and 15 ㏈ ENR, and 0.27 ㏈ for those of 21 ㏈.

Comparison of the Measured Electrical Properties of Pig Internal Organs with the Given Values for Human Organs

  • Jung, Ji-Hyun;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.161-165
    • /
    • 2012
  • The electrical properties of pig internal organs including lung, liver, heart, kidney, blood, stomach, and small intestine are measured using an open-ended coaxial probe and an improved virtual transmission-line model. The measured complex permittivities of the pig organs are compared with the given values of the corresponding human organs. A similarity between these values is confirmed. For organs such as lung, liver, heart, and kidney that have regular texture and contents, the complex permittivities are almost identical to those of the corresponding human organs. The complex permittivities of human and pig blood are also very close in value. However, relatively large deviations are observed for the cases of stomach and small intestine because the internal contents of these organs significantly affect the measured electrical properties.

RF and Microwave Power Standards from 10 MHz to 40 GHz over Decades

  • Kang, Tae-Weon;Kwon, Jae-Yong;Park, Jeong-Il;Kang, No-Weon
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.88-93
    • /
    • 2018
  • Radio frequency (RF) and microwave power is one of the key quantities in the framework of electromagnetic measurement standards. Therefore, the stability of the power standard is essential to users' reliable measurements in various areas. Coaxial and waveguide thermistor mounts are used as transfer standards of RF and microwave power. Over decades, the effective efficiencies of thermistor mounts have been measured using coaxial and waveguide microcalorimeters in the frequency range of 10 MHz-40 GHz. The measurement uncertainty of the effective efficiency is evaluated. Results show that the power standards have been well maintained within the measurement uncertainty.

Evaluation of Discharge Characteristics Followed by the Development of Blumlein Pulsed Power Source (Blumlein 펄스파워 전원개발 및 방전특성 평가)

  • Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.99-105
    • /
    • 2010
  • This paper discussed the theoretical simulation results for developing the blumlein pulsed power source and showed the circuit configuration and the discharge characteristics of the realistic manufactured pulsed power system. In the simulation, the output voltage characteristics at a load resistor showed the general impulse shape when the impedance of a single coaxial cable is matched with the that of a load resistor. In addition, it is confirmed that output values of the pulsed power can be easily controlled by the duplication of coaxial cables and the pulsed waveform showed the general impulse characteristics. Specifically, the inception discharge voltage in the gap distance of 5[mm] between needle and plane electrodes is about 20[kV] and which is lower than about 29[kV] in 9[mm] due to the difference of the reaching time of the inception voltage. Therefore, this paper showed that the output voltage of the blumlein pulsed power source can be easily controlled.

Using leak coaxial cable, a wireless communications network plan in high-rise buildings (기술사마당: 기술자료 -초고층(超高層) 건물(建物) 내(內)에서 누설동축케이블을 이용한 무선통신(無線通信)네트워크 구축(構築) 방안-)

  • Lee, Soon-Jong;Lee, Moon-Ho
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.5
    • /
    • pp.42-47
    • /
    • 2011
  • Currently, wireless communication environment in high-rise buildings are limited in the basement and ground floor facilities are not in common use do not part, in case of disaster is difficult for efficient repression. In this paper, wireless communication facilities on the ground floor of the skyscraper by building infrastructure, wireless communications is proposed to eliminate shadows. That the presence of various wireless communication systems, wireless communication system proposed by this paper, TPS laying coaxial cable seals leak, and the propagation shades in place by installing indoor antenna is the solution to eliminate shadows. The wireless communications solutions reveal the advantages and features, a method of constructing the proposed design.

  • PDF

A SHIELDING EFFECTIVENESS of COATED CONDUCTIVE POLYMER for ELECTROMAGNETIC SHIELDING (전자파 차폐용 전도성 고분자 코팅재료의 차폐효율)

  • 최재옥;임윤석;장용무;서광석;구자윤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.624-627
    • /
    • 2000
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power which passes through the material under test. To measure the shielding effectiveness materials made by conductive polymer, the flanged coaxial transmission-line holder based in ASTM D4935-89, was fabricated. This apparatus has dynamic range between 95dB and 120dB in frequency range of 50Mhz-2Ghz. Furthermore, this system can be utilized to measure the shielding effectiveness of materials produced by conductive polymer and can be adapted for shielding materials design.

  • PDF

Spray Characteristics of Coaxial Swirl Injector under Ambient High Pressure Conditions (고압환경에서 동축 와류형 분사기의 분무특성)

  • Lim Byoungjik;Kim Jong-Gyu;Moon Il-Yoon;Kim Seung-Han;Han Yeoung-Min;Seol Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.288-291
    • /
    • 2004
  • The spray characteristics of coaxial swirl injector under ambient high pressure conditions were investigated in this paper. Three injectors were used to study the effect of recess length and fuel injector type(open or closed). In this research, experimental conditions(ambient gas density) were calculated by Buckingham Pi-theory and spray characteristics of the injectors were represented by mass flow rate according to the injection pressure, the spray angle, mass distribution, and mean diameter of droplet.

  • PDF