• Title/Summary/Keyword: coal waste

Search Result 249, Processing Time 0.032 seconds

Physico-chemical characterization of individual particles emitted from the air pollution point sources (대기 점오염원에서 배출되는 개별입자상물질의 물리화학적 특성)

  • Park Jeong-Ho;Suh Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.761-770
    • /
    • 2005
  • Scanning electron microscopy / energy dispersive X-ray analyzer(SEM/EDX) has played an important role for evaluation the source of atmospheric particle because it is a powerful tool for characterizing individual particles. The SEM/EDX system provides various physical parameters like optical diameter, as well as chemical information for a particle-by-particle basis. The purpose of the study was to classify individual particle emitted from the point sources based on clustering analysis and physico-chemical analysis by SEM/EDX. The total of 490 individual particle were analyzed at 8 point sources including coal-fired power plant, incinerator, H-C oil boiler, and metal manufacturing industry. The main components were Si and AI in the coal-fired power plant, Cl and Na in the domestic waste Incinerator, S in the H-C oil boiler and S and Fe in the metal manufactory industry, respectively.

The Construction Work Method of Mixed Coal Ash in Ash Pond to Recycle as a Horizontal Drain Material (수평배수재로 재활용하는 회사장 혼합석탄재의 시공 방안)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • The design for horizontal drain layer on soft ground starts from the decision that the material could be used or not, by verifying material condition in permeability of horizontal drain material according to the weight percent of the dry soil retained on #200 sieve. In the next step of the design, we estimate the thickness of horizontal drain layer to confirm trafficability of heavy machinery in construction work. Successively, the long-term functionality for good drainage of horizontal drain layer is checked and if needed, some means are considered. In this study, the system to recycle mixed coal ash in ash pond successfully as a horizontal drain material on soft ground is presented through the process and the result of its practical construction work. Namely, the pact is confirmed that mixed coal ash in ash pond should be sorted out by sieve screen to a certain extent and the remainders of this mixed coal ash on sieve openings be recycled, because the amount of finer particles than $75{\mu}m$ contained in mixed coal ash in ash pond is quite massive and irregular depending on the coal power plant or the location in same ash pond. In order to sort at large scale in situ, the dimension of a sieve squre hole and the sort-out method, etc. should be decided before the sort-out process. And, it is described that we need to manufacture classifier to sort out mixed coal ash in ash pond, too.

Effect on blood heavy metal concentration in gas poisoning by combustion of ignition coal: Pilot study (착화탄 연소에 의한 가스 중독 환자에서 혈중 중금속 농도의 영향에 대한 예비연구)

  • Lee, Sang Hwan;Lee, Juncheol;Cho, Yongil;Ko, Byuk Sung;Oh, Jaehoon;Kang, Hyunggoo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.127-132
    • /
    • 2021
  • Purpose: It is known that the most common cause of gas poisoning in Korea is suicide attempts by burning ignition coals. Ignition coals are made from waste wood, and studies have been reported that heavy metals are emitted when this coal is burned. However, there was no study on how much heavy metal poisoning occurs in the human body through this, so this study was planned to find out whether the concentration of heavy metals in the blood increased in patients exposed to ignition coal combustion. Methods: From April 2020 to April 2021, blood lead, mercury, and cadmium concentrations were investigated in carbon monoxide poisoning patients who visited one regional emergency medical center in Seoul, and their association with exposure time, source of poisoning, and rhabdomyolysis were investigated. Results: During the study period, a total of 136 carbon monoxide poisoning patients were tested for heavy metals, and 81 cases of poisoning by ignition coal were reported. When comparing poisoning caused by combustion of ignition coal and other substances, there was no difference in the concentrations of lead, mercury, and cadmium in the blood, and there was no difference in the number of patients above the reference range. However, the patients exposed to more than 5 hours of ignition coal gas exposure are more frequent than those in the group less than 5 hours in lead (51.4% vs. 23.9%, p=0.012). Conclusion: Compared to poisoning with other combustible substances, the blood concentration of lead, mercury, and cadmium does not increase further in patients with gas poisoning by ignition coal. However, prolonged exposure may result in elevated levels of lead.

Characterization of artificial aggregates fabricated from coal bottom ash containing much unburned carbon (미연탄소가 다량 함유된 석탄바닥재로 제조된 인공골재의 물성분석)

  • Kang, Min-A;Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • The artificial aggregates (AAs) were manufactured from the parent batch powders consisting of bottom ash containing excess unburned carbon and dredged soil, 7 : 3 weight ratio by direct sintering method and those physical properties were evaluated. Especially, the effects of waste glass or frit (NWG) which was made by addition of 5 wt% $Na_2O$ to the waste glass upon the bloating phenomenon of AAs were analyzed. The AAs manufactured from the parent batch powders showed a lower specific gravity than that of specimens containing waste glass or NWG due to excess u$Na_2O$nburned carbon which usually obstructs a sintering process. But, the waste glass added on parent batch powders promoted the sintering and densification thus increased the specific gravity of AAs. Also the specific gravity of AAs added with 5 wt% NWG, was lowered compared to that of AAs added with as-received waste glass. This is because of bloating of shell which captures gases owing to the lowered viscosity of liquid formed at the specimen surface caused by $Na_2O$ addition. In conclusion, the AAs sintered at above $1100^{\circ}C$ in this study showed characters of lightweight aggregate of specific gravity 1.15~1.34 and water absorption 11~19 %, and the bloating phenomenon of AAs was occurred at the shell rather black core part.

A Study on Recycling of Waste Polyethylene Film (폐폴리에틸렌 필름의 재활용에 관한 연구)

  • Lee, Hwan-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.182-188
    • /
    • 2008
  • The compounds of recycled polyethylene(PE) and fly-ashes were prepared. Polymers used were sorted PE from mixed plastics of household waste and Low Density Polyethylene(LDPE) and Linear Low Density Polyethylene(LLDPE) recycled from the scrap of packaging film plants. Fly-ashes were from the power plant and from the household waste incinerator. The tensile strength of recycled LDPE and LLDPE compounds decreased and the flexural modulus increased with greater amount of the power plant fly-ash. Anthracite fly-ash gave rise to slightly higher tensile and flexural strength of the LLDPE mixtures than bituminous coal fly-ash presumably due to higher content of unburned carbon. The incinerator fly-ash introduced to household waste PE enhanced both tensile strength and flexural modulus of the compounds. When LDPE and household waste PE were used together, the synergistic effect of incinerator fly-ash to household waste PE was offset by reduced crystallization of LDPE due to the filler particle. The compounds of household waste PE and incinerator fly-ash might be applied to structural materials for such as sewage pipe, which reduces the waste treatment cost and conserve the environment and resources.

Synthesis of Low-Priced Catalyst from Coal Fly Ash for Pyrolysis of Waste Low Density Polyethylene (석탄비산재(石炭飛散災)로부터 저밀도(低密度) 폴리에틸렌 폐기물(廢棄物) 열분해용(熱分解用) 저가(低價) 촉매(觸媒) 합성(合成))

  • Jeong, Byung-Hwan;Na, Jeong-Geol;Kim, Sang-Guk;Mo, Se-Young;Chung, Soo-Hyun
    • Resources Recycling
    • /
    • v.16 no.2 s.76
    • /
    • pp.48-55
    • /
    • 2007
  • A low-priced catalyst for pyrolysis of LDPE has been synthesized. Fly ash, which is waste material generated from coal-fired power plants was used as silica and alumna sources for solid acid catalyst. Amorphous silica-alumina catalysts (FSAs) were pre-pared by dissolution of silica and alumina from fly ash, followed by co-precipitation of the dissoluted ions. A series of LDPE pyrolysis were carried out in a thermogravimetric analyzer to investigate the effects of synthesis conditions such as NaOH/fly ash weight ratio and activation time one catalytic performance of FSAs. The physical properties of FSAs were examined and related to their catalytic performances. FSA(1.2-8) synthesized with NaOH/fly ash weight ratio of 1.2 and the activation time of 8 hours showed the best catalytic performance. The catalytic performance of FSA(1.2-8) was comparable with that of commercial catalysts and it was concluded that the FSA could be a good candidate for catalytic use in the recycling of waste polyolefins.

Establishment of a Safe Blasting Guideline for Pit Slopes in Pasir Coal Mine (파시르탄광의 사면안전을 위한 발파지침 수립 연구)

  • Choi, Byung-Hee;Ryu, Chang-Ha;SunWoo, Coon;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.418-426
    • /
    • 2008
  • A surface blasting method with a single tree face is currently used in Pasir Coal Mine in Indonesia. The single free face is usually the ground surface. This kind of blasting method is easy to use but inevitably causes enormous ground vibrations, which, in turn, can affect the stability of the slopes comprising the various boundaries of the open pit mine. In this regard, we decided to make a specific blasting guideline for the control of found vibrations to ensure the safety of the pit slopes and waste dumps of the mine. Firstly, we derived a prediction equation for the ground vibration levels that could be occurred during blasting in the pits. Then, we set the allowable levels of ground vibrations for the pit slopes and waste dumps as peak particle velocities of 120mm/s and 60mm/s, respectively. From the prediction equation and allowable levels, safe scaled distances were established for field use. The blast design equations for the pit slopes and waste dumps were $D_s{\geq}5\;and\;D_S{\geq}10$ respectively. We also provide several standard blasting patterns for the hole depths of $3.3{sim}8.8m$.

Assessment of Water Pollution by the discharged water of the Abandended Mine

  • Kim, Hee-Joung;Yang, Jae-E.;Lee, Jai-Young;Park, Beang-Kil;Choi, Sang-Il;Jun, Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.167-174
    • /
    • 2004
  • Several metalliferous and coal mines, including Myungjin, Seojin and Okdong located at the upper watershed of Okdong stream, were abandoned or closed since 1988 due to the mining industry promotion policy and thus disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water pollution in the downstream areas. AMD and waste effluents from the closed coal mines were very strongly acidic showing pH ranges of 2.7 to 4.5 and had a high level of total dissolved solid (TDS) showing the ranges of 1,030 to 1,947 mg/L. Also heavy metal concentrations in these samples such as Fe, Cu, Cd and anion such as sulfate were very high. These parameters of AMD and effluents were considered to be highly polluted as compared to those in the main stream area of the Okdong river and be major pollutants for water and soil in tile downstream area. Pollution indices of the surface water at the upper stream of Okdong river where AMD of the abandoned coal mines was flowed into main stream were in the ranges of 16.3 to 47.1. On the other hand, those at the mid stream where effluents from tailing dams and coal mines flowed into main stream were in tile ranges of 10.6 to 19.5. However, those at the lower stream were ranged from 10.6 to 14.9 These results indicated that mining wastes such as AMD and effluents from the closed mines were tile major source to water pollution at the Okdong stream areas.

  • PDF

A Study on the Development of the Mercury Emission Factor from Coal-fired Power Plant (석탄 화력발전시설에서의 수은 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Park, Jung-Min;Jang, Kee-Won;Lee, Sang-Bo;Jung, No-El;Song, Deok-Jong;Hong, Ji-Hyung;Lee, Suk-Jo;Kim, Sang-Kyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.172-181
    • /
    • 2012
  • Mercury is one of the most hazardous air pollutants. Recently, mercury has been a concern in domestic and overseas because it has lethal toxicity, long distance transport, persistence and bioaccumulation in the environment. Stationary combustion sources such as coal-fired power plants, waste incinerators, and cement kilns are the major sources of mercury emissions. The objectives of this study were to measure the concentration for mercury from coal-fired power plants and to calculate emission factor to estimate its emission. The results showed that the mercury concentrations in the flue gas were 1.63-3.03 mg/$Sm^3$ in anthracite-fired power plants (average 2.32 mg/$Sm^3$) and 1.95-3.33 mg/$Sm^3$ in bituminous-fired power plants (average 2.6 mg/$Sm^3$). Mercury emission factor was estimated as 25.74 mg/ton for anthracite-fired power plants and 12.48 mg/ton for bituminous-fired power plants. Because actual measurements are limited in quantity, it is desirable to refine our estimates by extending the actual measurements.

Preparation and characterization of SRF(Solid Refuse Fuel) using heavy oil fly ash (중유회를 활용한 고형연료 제조 및 특성)

  • Min, Hong;Cho, Sung-su;Seo, Minhye;Lee, Soo-Young;Choi, Changsik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.4
    • /
    • pp.83-90
    • /
    • 2019
  • In this study, the characteristics of the SRF (Solid Refuse Fuel) prepared by blending each of the additives (citrus peel, waste wood, coal) in the heavy oil fly ash, evaluating the heavy oil fly ash recyclability. Recycling SRFs were fabricated by pellet extruding method after blending the heavy oil fly ash and additives based on 30% moisture content. As a result, the formability of the SRFs was excellent under condition of blending heavy oil fly ash with coal or citrus peel and the highest calorific value was 4,274 kcal/kg at heavy oil fly ash mixed with coal. Therefore, the formability and calorific value were improved when the heavy oil fly ash was mixed with coal(20 wt%) at 30% moisture content. From these results, the applicability of SRFs with additives was confirmed by using the heavy oil fly ash from J thermal power plant.