• Title/Summary/Keyword: coagulant dosage

Search Result 133, Processing Time 0.029 seconds

The Method of Automathic Operation of Coagulant Dosage by the quality of water (수질에 따른 응집제 주입 자동운영 방안)

  • Jun, Uk-Pyo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.278-283
    • /
    • 2005
  • Generally Jar-Test is available to determine the coagulant dosage rate. Disadventages associated with Jar-Test are that regular samples have to be taken requiring manual intervention and the limitation to feedback control. To deal with this difficulty, determined optimized dosage rates of coagulant to investigates the union operation method of the statistical equation which uses the multi-regression method and the SCD.

  • PDF

The Method of Optimum Operation of Coagulant Dosage Facility (응집제 주입설비 최적 운영방안)

  • Jun, Uk-Pyo;Oh, Sueg-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.275-281
    • /
    • 2004
  • Generally Jar-Test is available to determine the coagulant dosage rate. Disadventages associated with Jar-Test are that regular samples have to be taken requiring manual intervention and the limitation to feedback control. To deal with this difficulty, determined optimized dosage rates of coagulant to Investigates the union operation method of the statistical equation which uses the multi-regression method and the SCD.

  • PDF

A Study on the Coagulant Dosage Control in the Water Treatment Using Real Number Genetic-Fuzzy (실수형 유전-퍼지를 이용한 정수장 응집제주입제어에 관한 연구)

  • Kim, Yong-Yeol;Kang, E-Sok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.312-319
    • /
    • 2004
  • The optimum dosage control is presumably the goal of every water treatment plant. However it is difficult to determine the dosage rate of coagulant, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the real number genetic-fuzzy system was used in determining the dosage rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population which consists of codings of parameter set. To apply this algorithms, we made the real number rule table and membership function from the actual operation data of the water treatment plant. We determined optimum dosages of coagulant(LAS) using the fuzzy operation and compared them with the dosage rate of the actual operation data.

Characteristics of Mixing and Coagulation in an Inline Coagulant Mixing System (인라인 응집제 혼화시스템의 혼화 및 응집특성)

  • Yang, Hei-Cheon;Park, Sang-Kyoo;Wang, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3139-3143
    • /
    • 2007
  • The objective of this paper was to investigate the mixing characteristics of an three-stage inline coagulant mixing system experimentally. Wastewater samples of pH 8.5 and initial turbidity 1,000NTU were taken from a site of tunneling work. At the constant dosage, 0.36mL/L, of polymer as coagulant aids, the coagulation efficiency with the dosage of PAC as coagulant was about 4${\sim}$6% at 10 minutes after sampling. In the case of 2 different velocity gradient conditions, the efficiency of turbidity removal was increased about 6.5${\sim}$8% with increasing the dosage of coagulant while, the efficiency was increased about 20${\sim}$21.5% with increasing the dosage of coagulant aids. The efficiency of turbidity removal with the settling time after sampling was about 90% after 1 minute, and the efficiency was about 95% after 5 minutes.

  • PDF

Automatic T-P Coagulation Control System using an EC in the MSBR Process - Full Scale Study - (MSBR 공정에서 전기전도도를 이용한 인 제거 자동제어시스템 - 현장 적용 중심 -)

  • Jang, Hee-seon;Lee, Ho-sik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.90-96
    • /
    • 2017
  • Many sewage treatment plants have applied the advanced technology of chemical coagulant system to remove phosporus in Korea. However there are some problems for the injection of optimum coagulant dosage. In order to solve these problems, the research related to the more cost-effective automatic total phosphorus coagulation control system using an EC(Electrical Conductivity) have been in progress. This study was conducted by the same process and operation method as the Lab-scale for public small town sewage treatment plant. First, it confirmed the correlation among the EC, PO4-P and coagulant dosage in the Lab-scale MSBR(Membrane Sequencing Batch Reactor) process. Next, it analyzed that correlation coefficient of EC and the coagulant dosage was 0.92 in the Full-scale MSBR process. As a result, not only T-P removal efficiency was doubled but also it satisfied the effluent water quality standard in a stable manner. In addition, by applying the automatic control system using the EC, compared to the fixed coagulant injection system the coagulant dosage could be reduced by 28%.

Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities (하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토)

  • Jang, Yeoju;Jung, Jinhong;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

Study on Change of Microbial Activity and Removal Efficiency of Phosphorus with Alum Injection in the Biological Process (생물학적 처리공정 내 Alum 주입에 따른 인 처리 효율과 미생물 활성도 변화에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.188-193
    • /
    • 2011
  • The effects of coagulants on the microorganisms when they are injected directly into the biological treatment facility for T-P removal have been easily observed from the results of past experiments. As such this study is set out to derive the effective plans for the coagulant dosage by analyzing the effects of the injected coagulant on the microbial activity during the chemical treatment for T-P removal. The research methods entailed the assessment of removal efficiency of T-P according to the coagulant dosage while changing the molar ration between Alum and influent phosphorus. At the same time Specific Oxygen Uptake Rate (SOUR) according to the coagulant dosage was measured. SOUR was used as a method for indirect assessment of the microbial activity according to the coagulant dosage. The results from the study showed that with the increase in the alum dosage, the removal efficiency T-P tended to increase. On the other hand, the increase in coagulant dosage resulted in the decrease in SOUR, which indicates the decrease in the microbial activity. Such reduction in the activity could be explained by the increase in the concentration of removal efficiency of $TBOD_5$. Based on experiment results from the study, it is determined that coagulant dosage affects the microbial activity. Moreover, the indirect assessment on the microbial activity using SOUR is considered possible.

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF

Fuzzy modeling and control for coagulant dosing process in water purification system (상수처리시스템 응집제 주입공정 퍼지 모델링과 제어)

  • 이수범;남의석;이봉국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.282-285
    • /
    • 1996
  • In the water purification plant, the raw water is promptly purified by injecting chemicals. The amount of chemicals is directly related to water quality such as turbidity, temperature, pH and alkalinity. At present, however, the process of chemical reaction to the turbidity has not been clarified as yet. Since the process of coagulant dosage has no feedback signal, the amount of chemical can not be calculated from water quality data which were sensed from the plant. Accordingly, it has to be judged and determined by Jar-Test data which were made by skilled operators. In this paper, it is concerned to model and control the coagulant dosing process using jar-test results in order to predict optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride). The considering relations to the reaction of coagulation and flocculation, the five independent variables(turbidity, temperature, pH, Alkalinity of the raw water, PAC feed rate) are selected out and they are put into calculation to develope a neural network model and a fuzzy model for coagulant dosing process in water purification system. These model are utilized to predict optimum coagulant dosage which can minimize the water turbidity in flocculator. The efficacy of the proposed control schemes was examined by the field test.

  • PDF

Utilization of response surface methodology to optimize a coagulation-flocculation process for tunnel wastewater treatment (반응표면분석법을 이용한 터널폐수 응집-혼화 공정의 주요인자 영향 분석 및 최적화)

  • Jeong, Se-Uk;Lee, Jae-Hyun;Park, Tae-Won;Kim, Young Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.601-608
    • /
    • 2014
  • A coagulation-flocculation (CF) process using aluminum sulfate as a coagulant was employed to treat highly suspended solids in tunnel wastewater. Response surface methodology (RSM) based on a Box-Behnken design was applied to evaluate the effects of three factors (coagulant dosage, pH and temperature) on total suspended solids (TSS) removal efficiency as well as to identify optimal values of those factors to maximize removal of TSS. Optimal conditions of coagulant dosage and pH for maximum TSS removal changed depending on the temperature ($4{\sim}24^{\circ}C$). As temperature increased, the amount of coagulant dosage and pH level decreased for maximum TSS removal efficiency during the CF process. Proper adjustment of optimal pH and coagulant dosage to accommodate temperature fluctuations can improve TSS removal performance of the CF process.