• Title/Summary/Keyword: co-curing

Search Result 449, Processing Time 0.023 seconds

Properties and Suitability of Bark Extractives from Larix leptolepsis as a Bonding Agent (낙엽송(落葉松) 수피추출물(樹皮抽出物)의 특성(特性)과 접착제화(接着劑化)의 적합성(適合性))

  • Oh, Jung Do;Ahn, Won Yung
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.294-302
    • /
    • 1988
  • The experiment was carried out to investigate the properties of bark extractives form Larix epilepsies and to evacuate their suitability as a bonding agent. The yield and reactivity were measured to examine the influence of temperature and time and the effect of carbonation and sulfonation. To define the possibility of practical application as wood adhesives the viscosity and gelation time were measured at 33% concentration. The results obtained were summarized as follows : 1. As the both yield and reactivity were high, extraction for 2 hours at $80^{\circ}C$ was the optimal temperature and time. 2. The highest effect achieved at 1% $Na_2CO_3$ about carbonation and 1% $Na_2SO_3$ : $NaHSO_3$ and 0.25% $Na_2SO_3$ about sulfonation. The sulfonation of 0.25% $Na_2SO_3$ increased the yield and reactivity most highly. 3. By using hot water as extraction liquid the yield was 17.2%, while the addition of 1% and 5% NaOH to the extraction liquid increased the yield to 38.6% and 44.6%, respectively. 4. Hot water extracts showed the highest reactivity(68.8%). The addition of 1% and 5% NaOH led to decrease in reactivity(49.3% and 25.8%, respectively). 5. At 33% concentration of the extracts the viscosity appeared very variable. Significantly high values of viscosity was measured in 1% NaOH solution, while very low values appeared for 5% NaOH solution. 6. The shortest gelation time was determined at pH 7 to 10 and the highest at pH 4. The use of paraformaldehyde resulted in gelation times longer than those of 37% formaldehyde solution. 7. Except the sulfonation extracts of hot water and 1% NaOH, the other extracts were found unsuitable due to high viscosity(1% NaOH extracts, sulfonation extracts) or to curing inability(5% NaOH extracts, sulfonation extracts of 5% NaOH). 8. From the three extract solutions which appeared to be suitable for use as bonding agents the hot water extracts and the sulfonation extracts of hot water were superior in extract reactivity, while the sulfonation extracts of 1% NaOH exceeded the other two extracts in extract yield.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS (All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향)

  • Lee, Bum-Eui;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.66-78
    • /
    • 2004
  • The objective of this study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration in enamel and dentin achieved with those gained using the conventional technique and vibration technique. For enamel specimens, thirty teeth were sectioned mesio-distally. Sectioned two parts were assigned to same adhesive system but different treatment(vibration vs. non-vibration). Each specimen was embedded in 1-inch inner diameter PVC pipe with a acrylic resin. The buccal and lingual surfaces were placed so that the tooth and the embedding medium were at the same level. The samples were subsequently polished silicon carbide abrasive papers. Each adhesive system was applied according to its manufacture's instruction. Vibration groups were additionally vibrated for 15 seconds before curing. For dentin specimen, except removing the coronal part and placing occlusal surface at the mold level, the remaining procedures were same as enamel specimen. Resin composite(Z250. 3M. U.S.A.) was condensed on to the prepared surface in two increments using a mold kit(Ultradent Inc., U.S.A.). Each increments was light cured for 40 seconds. After 24 hours in tap water at room temperature, the specimens were thermocycled for 1000cycles. Shear bond strengths were measured with a universal testing machine(Instron 4465, England). To investigate infiltration patterns of adhesive materials, the surface of specimens was examined with scanning electron microscope. The results were as follows: 1. In enamel the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration group(group 1, 3, 5). The differences were statistically significant except AQ bond group. 2. In dentin, the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration groups(group 1, 3, 5). But the differences were not statistically significant except One-Up Bond F group. 3. The vibration group showed more mineral loss in enamel and longer resin tag and greater number of lateral branches in dentin under SEM examination.

  • PDF

PROPERTIES OF FLUORIDE-RELEASING RESIN COMPOSITE RESTORATIVE MATERIALS (불소방출성 콤포짓트 레진계 수복재의 특성)

  • Kim, Sang-Hoon;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.418-426
    • /
    • 2008
  • The objectives of this study were to examine the properties of fluoride-releasing resin composite restorative materials. Four commercially available compomer materials (Compoglass F: CF, $Dyract^{(R)}$ AP: DA, $Dyract^{(R)}$ flow: DF, F2000: FT) and one fluoride-releasing composite resin ($Tetric^{(R)}$ Ceram: TC) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Disk-shaped specimens were fabricated in the split teflon mold with diameter of 15mm and thickness of 1mm. After curing for an hour, specimens were immersed in deionized water at $37^{\circ}C{\pm}1^{\circ}C$ for 30 days. All specimens were thermocycled for 10,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Toothbrush abrasion test was conducted under a load of 1.5 N and the abraded surfaces were examined with surface roughness tester (SV-3000, Mitutoyo Co, Japan) and SEM (JSM-5800, JEOL, Japan). Fluoride recharging was done by toothbrushing for 3 min. using a fluoride toothpaste (Perio Alpine Herb, LG Household & Health Care, Korea). The results obtained were summarized as follows; 1. The highest tensile strength value of 32.3 MPa was observed in TC group and the lowest value of 16.8 MPa was observed in CF group. The tensile strength of TC group was significantly higher than those of CF and DF groups (P<0.05). 2. The lowest Ra value of 0.287 was observed in TC group and the highest value of 1.516 was observed in FT group. The Ra value of FT group was significantly higher than other groups (P<0.05). 3. The abraded surfaces revealed the increase of surface roughness due to the protrusion and missing of filler particles. 4. The release of fluoride of compomers after tooth brushing by Perio Alpine Herb was initially large and then followed by small and continuously. But it remains small and constant in fluoride-releasing composite resin of TC. 5. The highest value of fluoride release after toothbrushing by Perio Alpine Herb was $2.064{\mu}g/cm^2$ in CF group and the lowest value was $0.1119{\mu}g/cm^2$ in TC group. The amount of fluoride release of CF group was significantly higher than other groups (P<0.05).

  • PDF

Effects of Polyimide Passivation Layers and polyvinylalcohol Passivation Layers for Organic Thin-Film Transistors(OTFTs) (폴리이미드 패시베이션과 폴리비닐알콜 패시베이션 레이어 성막이 고성능 유기박막 트렌지스터에 주는 영향)

  • Park, Il-Houng;Hyung, Gun-Woo;Choi, Hak-Bum;Hwang, Sun-Wook;Kim, Young-Kwan
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.195-198
    • /
    • 2008
  • In this paper, it was demonstrated that organic thin-film transistors (OTFTs) were fabricated with the organic passivation layer by vapor deposition polymerization (VDP) processing. In order to form polymeric film as a passivation layer, VDP process was also introduced instead of spin-coating process, where polymeric film was co-deposited by high-vacuum thermal evaporation from 6FDA and ODA followed by curing. In order to investigate by compared with different passivation layer, the other OTFTs is fabricated to passivation by Polyvinylalcohol using spincoating. We can see that two different ways of passivation layer affect electric characteristic of OTFTs. The initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.24cm^2/Vs$, -3V, and $10^6$, respectively. Then after polyimide passivation layer, field effect mobility change from $0.24cm^2/Vs$ to $0.26cm^2/Vs$, threshold voltage from -3V to 1V and on-off current ratio from $10^6$ to $10^6$, respectively. In the case of polyvinylalcohol passivation, the initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.13cm^2/Vs$, 0V, and $10^6$, respectively. Then after polyvinylalcohol passivation layer, field effect mobility changes from $0.13cm^2/Vs$ to $0.13cm^2/Vs$, threshold voltage from 0V to 2V, and on-off current ratio from $10^6$ to $10^5$, respectively.

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF

Interpretation of Limestone Provenance, Materials and Making Characteristics for Lime-Soil Mixture on Tomb Barrier of the Yesan Mokri Site in Joseon Dynasty (조선시대 예산 목리유적 회격묘의 재질 및 제작특성과 석회의 산지 해석)

  • Lee, Chan Hee;Cho, Ji Hyun;Kim, Jiyoung
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.471-490
    • /
    • 2016
  • This study investigated provenance of raw materials and making technique of lime-based materials used in the tomb barriers of the Yesan Mokri tombs from Joseon dynasty on the basis of analysis to material characteristics and physical properties. In the barrier materials, dry density and porosity are the highest value ($1.82g/cm^3$) and the lowest value (25.20%) in the south wall of No. 1 tomb, respectively. Dry density and porosity are inversely proportional in all barrier materials, but unconfined compressive strength, which is the highest value of $182.36kg/cm^2$ in the No. 2 tomb, does not show an interrelation with porosity and density. Mineral components in the lime-soil mixtures of the tomb barrier are mainly quartz, feldspar, mica and calcite about 200 to $600{\mu}m$ size with yellowish brown matrix. Hydrotalcite and portlandite are detected in the lime mixture, and kaolinite in the soils. The lime materials of the tomb barrier occurred in large quantities weight loss and variable endothermic peaks caused by decarbonization reaction of $CaCO_3$ in the range from 600 to $800^{\circ}C$ in thermal analysis. Making temperature of lime for the tomb barrier is presumed approximately about $800^{\circ}C$ based on the occurrences, compositions and thermal analysis. The tomb barriers are revealed to very wide composition ranges of major elements and loss-on-ignition (22.5 to 33.6 wt.%) owing to mixture of the three materials (lime, sand and clay). It is interpreted that low quality construction technique was applied as the limes are very heterogeneous mixture with aggregates, and curing of the lime was poorly processed in the tomb barriers. Possible limestone sources are distributed in many areas around the Mokri site where limestone conformation and quarries for commercial production are found within Yesan and Hongseong areas. Therefore, we estimated that raw materials were possibly supplied from the local mines near the Mokri site.

EFFECT OF ACID-TREATMENT ON DENTIN BONDING (산 처리가 상아질 접착에 미치는 영향)

  • Kim, Young-Kyong;Kim, Sung-Kyo;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.73-83
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of various acid treatments on dentin bonding. Freshly extracted human teeth were uprightly embedded in self curing acrylic resin, and their occlusal surfaces were grinded to expose flat dentin surfaces. The specimens were divided into 4 groups. Specimens of one group were not treated so as to be a control and those of the other three groups were threated with 10% polyacrylic acid, 10% phosphoric acid, and 10-3 solution(10% citric acid/3% ferric chloride) respectively. Primer, bonding resin and composite resin were applied over the treated dentin surfaces sequentially. All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, then the tensile bond strength was measured and the treated dentin surfaces and fracured dentin surfaces were examined under a scanning electron microscope. The results were as follows: Bond strengths of acid-treated groups were higher than those of the untreated group. In the acid-treated groups, bond strength was found to be the highest in the 10-3 solution group followed by the 10% phosphoric acid group and the 10% polyacrylic acid group(P<0.01). On SEM examination of dentin surfaces, the untreated dentin surface showed a remaining smear layer and closed dentinal tubules. Dentin surfaces treated with 10 % polyacrylic acid showed a clean dentin surface without the smear layer, but showed remaining smear plugs in dentinal tubules. A dentin surface treated with 10% phosphoric acid or 10-3 solution showed open dentinal tubules without the smear layer or smear plugs. On SEM observation of the fractured dentin-resin interface, the untreated group showed that failure occurred in the smear layer. The group treated with 10% polyacrylic acid showed no resin tag remained in the dentinal tubules, but resin tags in the dentinal tubules were observed in the group treated with the 10% phosphoric acid or the 10-3 solution. On the failure mode examination, the higher the bond strength of the group, the higher the frequency of cohesive failure. The coefficient between bond strength and cohesive failure rate was 0.71.

  • PDF

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).