• Title/Summary/Keyword: clothing microclimate temperature

Search Result 113, Processing Time 0.025 seconds

Human Responses to Pattern Ease of Base Layer with Abdominal Heating Pads (복부 가열 패드를 부착한 상의 베이스 레이어의 여유량에 따른 인체 반응)

  • Lee, Gyeongmi;Hong, Kyunghi;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.687-697
    • /
    • 2017
  • To figure out an appropriate pressure level for a body warming base layer, human responses were observed when the pattern reduction of base layers varied. Under the condition of $2^{\circ}C$, 60% RH, 0.1m/s, ten male subjects participated in the experiment with four sizes of experimental vests where heating pads were attached. The subjective evaluations of the heating vests with different sizes were reported using 7 or 9 point scales. We simultaneously observed chest, abdomen and scapula skin temperatures and microclimate humidity. It was found that the tight pattern as in the case of A or B provided a warmer subjective sensation and skin temperature than C or D; however, there were no differences in skin temperature at the chest. Eventually, the chest temperature decreased after about 30 mins of heating; however, temperature of abdomen increased and indicated that heating with two commercial pads used was inadequate for whole body warming. The pressure sensation of 'tight' was improved after warming the abdomen in a cold environment. Overall, the gaps beyond the original circumference of the abdomen, as in C or D, were not desirable for the local heating of abdomen under the conditions of this experiment where walking was included in the protocol. The experiment garment B with nude waist circumference was the best, and D with the largest ease, was the worst for a comfortable warming vest.

Effectsd of posture on physiological thermal responses with Ondol heating system (온돌난방에서의 자세에 따른 온열생리적 반응의 성차)

  • 신정화;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

A Study on Thermoregulation by different allowance of T-shirts (상의의 여유량 차이에 따른 체온조절반응 연구)

  • 장지혜;이소진;류정민
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.5
    • /
    • pp.39-47
    • /
    • 2001
  • The purpose of this study was to investigate two different kinds of t-shirts on thermal responses at air temperature of $23{\pm}2^{\circ}C$, relative humidity of $70{\pm}5%$ and wind velocity not more than 0.5 m/sec. Five healthy men wearing boxy type t-shirts or fitted type t-shirts, participated as the subjects. Rectal temperature, skin temperatures, heart rate, clothing microclimate and subjective sensation were measured every 2 minute during experiment(rest, walking, recovery each 20 min.) and compared between two experimental garments(boxy type and fitted type t-shirts). Rectal temperature was lower in recovery phase at wearing fitted type t-shirts. Chest skin temperature was higher at wearing fitted type t-shirts and thigh and leg skin temperature were higher at wearing boxy type t-shirts.

  • PDF

Wearing Comfort Evaluation of a Summer Flight Suit to Improve Ventilation (통기성 향상을 위한 하계비행복 설계 및 착용쾌적성 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.3
    • /
    • pp.485-491
    • /
    • 2014
  • This study verified the effect of summer flight ventilation developed in a previous study based on wearing comfort evaluation. Seven healthy males in their twenties volunteered for this experiment conducted in aclimatic chamber. The experiment consisted of three consecutive periods of rest (20 minutes), running on a treadmill (10 minutes) and recovery (20 minutes). A comparative evaluation was conducted on the general flight suit which had no ventilation holes and summer flight suit that use subjective satisfaction measures and objective measures. The subjective satisfaction was evaluated according to the criteria of temperature sensation, wet sensation, thermal comfort and fatigue sensation. The objective satisfaction was measured by skin temperature, microclimate (temperature and humidity), sweat rate and thermography. The comparative wearing evaluation identified the summer flight suit decreased the temperature between skin and suit by $0.42^{\circ}C$ (upper arm), $0.9^{\circ}C$ (calf) and the skin temperature by $0.3^{\circ}C$ (shoulder), $0.4^{\circ}C$ (upper arm), $0.5^{\circ}C$ (calf) as compared to the general flight suit. The humidity inside the summer flight suit decreased at head (7.73%), shoulder (5.86%), upper arm (5.26%), and calf (8.73%) compared to the one inside the general flight suit. Thermography showed that the air flowed through ventilation holes (neck and armpit). The design of ventilation holes applied to the summer flight suit can be applicable to overall clothing that requires thermal comfort such as dust-free garments, mechanical clothing and combat uniforms.

Preparation and Physical Characteristics of High-Performance Heat Storage.Release Fabrics with PCMMc : Wet coating process (상전이 마이크로캡슐이 함유된 고기능성 축열.발열 직물의 제조 및 물리적 특성 : 습식코팅)

  • Koo, Kang;Choe, Jong-Deok;Choi, Jong-Suk;Kim, Eun-Ae;Park, Young-Mi
    • Textile Coloration and Finishing
    • /
    • v.19 no.1 s.92
    • /
    • pp.24-30
    • /
    • 2007
  • Heat storage/release system in textile is a useful tool to increase energy efficiency and enhance comfortable microclimate of clothing. Phase change materials(PCM) are used in regulating storage and release properties of thermal energy. To investigate the temperature regulating ability of fabrics with PCM microcapsule(PCMMc), Nylon fabrics were coated with PCMMc via wet processing and they were characterized by SEM, DSC and infrared thermal analyzer. Also, water moisture transpiration, water penetration resistance, peel strength and washing durability of the fabrics were assessed. The water vapor permeation and water penetration resistance decreased with increasing PCMMc content. In DSC analysis, it can be seen that the microencapsulated fabric showed both exothermic md endothermic phenomena at specific temperature. Peel strength was decreased with increasing PCMMc content.

Effects of Wear Training for Improving Vascular Compliance on Blood Pressures and Blood Lipid Profiles in Prehypertensive Subjects (온열요법으로서의 착의훈련이 고혈압 전단계자의 혈압 및 혈중 지질성분에 미치는 영향)

  • Yoo, Shin-Jung;Park, Joon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.21 no.1
    • /
    • pp.141-149
    • /
    • 2012
  • This study investigates the effects of wear training on blood pressure and blood lipid profiles. For the purpose of this research, 'wear training' refers to the alternating stimulation of temperature while using specific clothing under controlled situations ($18.8{\pm}0.2^{\circ}C$, $38{\pm}3%RH$). The participants alternated between two different garments producing a $1.5^{\circ}C$ difference in the innerest microclimate temperature over a period of 4 weeks. The experiments in this study were conducted in a comfortable environment after sufficient rest. The results were as follows. The systolic blood pressure and mean arterial pressure were lower in the post test than in the pre test (p<.05). The atherogenic index (AI) was also reduced and the LDL-C/HDL-C ratio increased (p<.05) in the post test. These results demonstrated that wear training positively affected improvement in vascular stiffness.

Permissible Safety Limits in Local Cooling Focused on the Parts of Human Body (신체 부위별 냉각허용한계온도에 관한 연구)

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Kim, Kyung-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.119-130
    • /
    • 2007
  • The objects of this study were to investigate responses and peculiarity during local cooling by parts of the human body and to show permissible safety limits without injurious to his health because of excessive cooling when he works hot environments. It were measured rectal temperature, skin temperature, heart rate, total body weight loss, local sweat in back and thigh, clothing microclimate and subjective sensation on 8 subjects and cooling parts were head, neck, chest, abdomen, back, waist, hip, upper arm, forearm, hand, thigh, calf and foot. According to above-mentioned the first experiment, we chose permissible safety limits by parts of the human body for one hour. In the second experiment, it was showed permissible safety limits by parts which examined their safety about health through 4 hours cooling test on 3 subjects. The results are as follows: 1. As a result of the first experiment, we chose permissible safety limits by parts, as follows, head $25^{\circ}C$, neck $20^{\circ}C$, chest $27^{\circ}C$, abdomen $25^{\circ}C$, back $20^{\circ}C$, waist $20^{\circ}C$, upper arm $20^{\circ}C$, forearm $20^{\circ}C$, hand $23^{\circ}C$, thigh $20^{\circ}C$, calf $20^{\circ}C$ and foot $23^{\circ}C$ in $37^{\circ}C$, 50%R.H. environment for 1 hour. 2. As a result of the second experiment, cooling on these safety limits temperatures except chest didn't have a bad effect on health. So it was proved that right permissible safety limits of chest was $28^{\circ}C$. From these results, it has been suggested that skin temperature didn't fall below permissible safety limits when human body was to be cool by parts.

Physiological Responses to Different Exercise Intensities while Wearing Different Types of Sportswear Materials (스포츠웨어 착용에 따른 운동시 온열생리반응에 미치는 영향)

  • Kim, Tae-Gyou;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.8 no.1
    • /
    • pp.123-128
    • /
    • 2006
  • For the purpose of examining the relationship of physiological and subjective responses to different exercise intensities and varied types of sportswear material, under environmental condition $20{\pm}1^{\circ}C$ $50{\pm}3%$RH, five men who wear four different kinds of sportswear which have same clothing cover area. The subjects exercised for 20 min with a 20 min pre-exercise rest period and another 20 min post-exercise recovery period. Throughout the 60 min. duration, we monitored the local skin temperature, rectal temperature, clothing microclimate and subjective sensation. The mean skin temperature was recorded to range from $33.5{\sim}34.1^{\circ}C$ for the entire duration of the experiment with the highest temperature observed at the 7th min after starting the exercise. During the exercise intensity at THR 20, the lowest recorded temperature was at the 5th min of the recovery time and stabilized at the 10th min. However, in the exercise intensity condition at THR 70, the temperature declined steadily until the end of the experiment. With regard to clothing materials, cotton 100% and Polyester/Cotton blended fabrics knit(35/65) was $0.5{\sim}0.7^{\circ}C$ maintained lower than Polyester 100% and polyester/Cotton blended woven fabrics (65/35). In the case of the rectal temperature at THR 70 in case of PET 100%, Polyester/Cotton blended woven fabrics (35/65) was higher $0.2{\sim}0.5^{\circ}C$ than other sportswear throughout the duration of the experiment.

A Study on Clothing Weight and Cornell Medical Index in Elderly Women (노인여성의 착의량과 건강관련변인)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.18 no.5
    • /
    • pp.1087-1092
    • /
    • 2009
  • From the environmental adaptation point of view, the clothing habits made by the thermal sensation and clothing weight of elderly women have changed according to the thermal sensation and health condition. The purpose of this study was to obtain the basic data for developing healthy and comfortable clothing for elderly women. Clothing weight, thermal sensation, clothing microclimate, resistance to cold and heat of 198 elderly women in Taejeon were surveyed from October 9, 2007 to October 19, 2007. 1. Clothing weight per body surface area was $830.4g/m^2$ of total clothing weight, $242.8g/m^2$ of underwear clothing weight, $617.3g/m^2$ of outerwear clothing weight, $419.8g/m^2$ of upper clothing weight, and $420.4g/m^2$ of lower clothing weight. 2. More than 90% of the respondents replied that they felt comfortable when the temperature inside the clothing was $33.5^{\circ}C$ and humidity inside the clothing was 30.2%. 3. The elderly women were more sensible to cold than to hot, those who felt cold had a tendency to wear heavier clothing. 4. The appeal rate for physical pain of older and lower income people, especially those with an income under 1,000,000 won, was higher than that of others. On the other hand, the lower the subjective economic level, the younger they were, and the more the monthly average income was, the higher the rate of mental pain. 5. The heavier the total clothing weight was, the higher the appeal rate for general pain.

Effect of Ondol on physiological Responses during Sleep (I) -On the focus of Bedclimate in Autumn and Winter- (온돌환경이 수면시의 생리반응에 미치는 영향(제1보) -가을, 겨울철 수면시 침실내 온열환경과 침상기후-)

  • Lee, Sun-Won;Gwon, Su-Ae;Choe, Jeong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.4
    • /
    • pp.697-706
    • /
    • 1996
  • The actual conditions of bed climate are investigated depending on the regions and housing styles used on ondol in autumn and winter. Sixty healthy men and women (30 of them live in apartmrnt and 30 of them live in detached house, 20 of them live in Wonju, 20 of them live in Wonju, 20 of them live in Cheongju and 20 of them live in Pusan) The results are as follows: 1) No significant differences was shown between the seasons of bedclothes thickness. 2) In the autumn, the temperature and humidity of bedroom, on the mattress, inside the bedquilt, and inside the sleep-wear were higher than those in the winter. The temperature of ondol floor and under the mattress in winter were higher than those in the autumn. 3) The differences of the temperature and humidity of bedroom, the bed climate, and the clothing microclimate were significant by the regions and housing styles in both seasons. In both seasons, the temperature of bedroom, on the mattress, inside sleep-wear in the apartment were higher than those in the detached house. 4) The differences of subjective sensation on the bedroom conditions were not significant by the sextons, the regions, and the housing styles. Most subjects perceived that the conditions of bedroom were somehow hot and dry, but comfortable.

  • PDF