• 제목/요약/키워드: closed loop system

검색결과 1,430건 처리시간 0.031초

냉각수 순환 형태의 파이프 쿨링 공법의 설계 (Design of Closed Loop Pipe Cooling System)

  • 박찬규;왕인수;구자중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.52-57
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. The pipe cooling method leads to the decrease of curing period by lagging materials as well as the decrease of temperature difference between center and surface of mass concrete member, There are two methods in the pipe cooling system, which are open loop system and closed loop system. However open loop pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation in the central area of city, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance results of hydration heat control with closed loop pipe cooling system.

  • PDF

비구조적인 불확실성을 가지는 시스템에 대한 반복 제어기의 설계 (Design of a repetitive controller for the system with unstructured uncertainty)

  • 도태용;문정호;정명진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.779-782
    • /
    • 1996
  • Repetitive control is a proposed control strategy in view of the internal model principle and achieves a high accuracy asymptotic tracking property by implementing a model that generates the periodic signals of period into the closed-loop system. Since the repetitive control system contains a periodic signal generator with positive feedback loop, which reduces the stability margin, in the overall closed-loop system, the stability of the closed-loop system should be considered as an important problem. In case that a real system has plant uncertainties which are not represented through modeling, the robust stability problem of the repetitive control system has not been considered sufficiently. In this paper, we propose the robust stability condition for the system with modeling uncertainty. The proposed robust stability condition will be obtained using the robust performance condition in the H$_{\infty}$ control. Moreover, by use of the proposed robust stability condition, we propose a procedure that designs a repetitive controller and a feedback controller simultaneously which can stabilize the overall closed-loop system robustly and which can also do the closedloop system without repetitive controller..

  • PDF

폐로식별기법에 의한 TRMS 모델링 (Modeling for Twin Rotor System Using CLID)

  • 이정경;권오규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.644-646
    • /
    • 2004
  • The closed loop identification(CLID) is a very useful method for on-line applications since it can identify the plant in the closed-loop system composed of the plant and the controller. There are some literatures on CLID, but they and mainly focused on SISO(Single-Input/Single-Output) problem. In this paper, a CLID method is proposed for MIMO(Multi-Input/Multi-Output) systems. The CLID method is applied to a MIMO benchmark plant, TRMS(Twin-Rotor MIMO System). To illustrate the performance of the closed-loop system identification., unit step responses in the TRMS are represented and compared with the open-loop identification via some simulation.

  • PDF

무금형 성형장치를 이용한 폐루프 판재성형 (Closed-loop Sheet Metal Forming Using Dieless Forming Apparatus)

  • 양승훈;박종우;홍예선;양현석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.62-65
    • /
    • 2002
  • A dieless forming system which consists of hydraulic punch elements and elastomer/fluid pads, was developed for sheet metal forming. 2-D curved surface forming was carried out using open-loop, closed-loop, and repeated forming method. Closed-loop exhibited higher decision than open-loop forming. Repeated forming also showed reduced spring back and possibility of high precision.

  • PDF

Robust Pole Assignment in a Specified Disk

  • Nguyen, Van-Giap;Nguyen, Tan-Tien;Lee, Gun-You;Kim, Sang-Bong
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권2호
    • /
    • pp.116-120
    • /
    • 2000
  • This paper presents a method to assign robustly the closed loop system's poles in a specified disk by a state feedback for a linear time invariant system with structured or unstructured uncertainties. THe proposed robust design procedure includes two steps. Firstly, the perturbed closed loop matrix $A_{cl p}$ = $A_{cl}$ + Δ$A_{cl}$ is rearranged such that it is a function of the nominal closed loop matrix $A_{cl}$. Hence, we can control the positions of the perturbed closed loop poles by choosing $A_{cl}$ appropriately. Secondly, the feedback control law F that assigns the closed loop poles of the perturbed system in a specified disk is determined from the equation $A_{cl}$ = A + BF. A procedure for finding F is proposed based on partitioning every matrix of the equation $A_{cl}$ = A + BF in the horizontal direction.

  • PDF

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

주파수역에서의 피드백시스템의 성능향상을 위한 제어기 Atuo-tuning 기법 (Controller Auto-tuning Scheme for Improving Feedback System Performance in Frequency Domain)

  • 정유철;이건복
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.26-30
    • /
    • 2001
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the con-ventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF

페푸프 제어 시스템을 위한 퍼지-신경망 기방 고장 진단 시스템의 개발 (Development of Neuro-Fuzzy-Based Fault Diagnostic System for Closed-Loop Control system)

  • 김성호;이성룡;강정규
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.494-501
    • /
    • 2001
  • In this paper an ANFIS(Adativo Neuro-Fuzzy Inference System)- based fault detection and diagnosis for a closed loop control system is proposed. The proposed diagnostic system contains two ANFIS. One is run as a parallel model within the model in closed loop control(MCL) and the other is run as a series-parallel model within the process in closed loop(PCL) for the generation of relevant symptoms for fault diagnosis. These symptoms are further processed by another classification logic with simple rules and neural network for process and controller fault diagnosis. Experimental results for a DC shunt motor control system illustrate the effectiveness of the proposed diagnostic scheme.

  • PDF

주파수역에서 피드백시스템의 성능향상을 위한 제어기 Auto-turning기법 (Controller Auto-tuning Scheme Improving Feedback System Performance in Frequency Domain)

  • 정유철;이건복
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.144-147
    • /
    • 2000
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the conventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF

냉각수 순환 형태의 파이프 쿨링 공법을 이용한 매스콘크리트 수화열 제어 (Hydartion Heat Control with Closed Loop Pipe Cooling System)

  • 박찬규;손상현;이승훈;장기욱;정재홍;김명식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.403-408
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. However, open pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance result of hydration heat control with closed loop pipe cooling system.