• Title/Summary/Keyword: closed and ventilated system

Search Result 6, Processing Time 0.02 seconds

Characteristics of Beeswax-treated Hanji Aged by Closed and Ventilated Chamber (밀폐 및 배기조건에서 열화된 밀랍지의 열화특성 분석)

  • Kang, Yeong Seok;Yang, Eun Jeong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.6
    • /
    • pp.9-14
    • /
    • 2012
  • Currently a variety of efforts to conserve and restore the injured the Annal of the Joseon Dynasty are continued and many studies about the aging pathway of the beeswax-treated volume have being progressed. In this study, two chambers were set up to assess the influence of VOCs(Volatile Organic Compounds) generated in process of beeswax deterioration. One chamber was closed and the other was continuously ventilated in order to remove the VOCs. In results, the acid compounds of beeswax-treated Hanjis aged in closed chamber was more than that aged in ventilated chamber. The folding endurance of beeswax-treated Hanjis aged in closed chamber was lower than that aged in ventilated chamber. Accumulated acid compounds of beeswax-treated Hanji in closed chamber may cause accelerated aging and strength decrease. In conclusion, accumulated acid compounds can accelerate the aging of beeswax-treated Hanji and cause the severe deterioration of inside of beeswax-treated volume. Therefore, to preserve more safely beeswax-treated volumes of the Annals of the Joseon Dynasty, it is essential that VOCs emitted from beeswax-treated volume are ventilated.

Visualization of ventilated supercavitation phenomena around a moving underwater body (수중 운동체 주변에 형성되는 환기 초공동(ventilated supercavitation) 현상 가시화)

  • Chung, Jaeho;Cho, Yeunwoo
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.26-29
    • /
    • 2015
  • A laboratory experiment was carried out to observe and visualize ventilated supercavitation phenomena around a moving underwater body which is attached to a newly designed high-speed (Max. 20 m/s) carriage system in a wave tank. Compared to the existing many other experimental studies using cavitation tunnels, where the body is at rest and the fluid is in motion in a bounded or closed environment, the present experimental study deals with super-cavity formation in unbounded or free-surface bounded environments, where the body is in motion and the fluid is at rest. Main attention is paid to the effective visualization of the steady-state cavity formations around a moving body and, those cavity formations are reported pictorially according to the body speed, ventilated air-pressure, and with or without a cavitator.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

Comparison of Two Different Smoke Extraction Schemes of Transversely Ventilated Tunnel Fire

  • Rie, Dong-Ho;Kim, Hyung-Taek;Yoo, Ji-Oh;Shin, Hyun-Jun;Yoon, Sung-Wook
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.30-35
    • /
    • 2005
  • In case of tunnel fire, one of the most effective facilities to save lives is the smoke control system. In this study, two different smoke extraction schemes of transversely ventilated tunnel were compared. One is the smoke extraction using the fixed exhaust ports on the false ceiling to achieve the uniform and distributed smoke extraction (uniform exhaust). The other is that using the remote controlled smoke extraction where only vents close to the fire is opened whereas the others are closed to enhance the limitation of the smoke spread (localized exhaust). A number of numerical simulations were performed to find out the optimal smoke extraction rate at each smoke extraction scheme to allow the tunnel users to escape to the safe area without endangering their lives by smoke.

Effects of a Closed Endotracheal Suction System on Oxygen Saturation, Ventilator-Associated Pneumonia, and Nursing Efficacy (폐쇄형 흡인술이 인공호흡기 환자의 산소포화도, 인공호흡기 관련 폐렴 및 흡인간호 효율성에 미치는 영향)

  • Lee Eun-Sook;Kim Sung-Hyo;Kim Jung-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.7
    • /
    • pp.1315-1325
    • /
    • 2004
  • Purpose: The purpose of this study was to examine the effects of a closed endotracheal suction system(CES) on oxygen saturation, ventilator associated pneumonia(VAP), and nursing efficacy in mechanically ventilated patients. Method: This study was conducted in the intensive care unit of a University Hospital in Gwangju City. Data was collected from July to October, 2003. Seventy mechanically ventilated patients were randomly divided into two groups; 32 for CES and 38 for open endotracheal suction system(OES) protocol. Twenty one nurses were also involved to examine the nurses' attitude of usefulness about CES. Result: $SaO_2$ was significantly different between CES and OES. The incidence of VAP in CES was lower than that of OES. Nursing efficacy was related to time, cost, and usefulness of the suction system. Time of suctioning in CES was shorter than that of OES. CES also contributed significantly to lower the cost of treatment than OES. The usefulness score of CES increased after 6 months of use. Conclusion: CES prevented VAP, was cost effective, and a safe suctioning system. CES can be used with patients with sensitivity to hypoxygenation and with a high risk of VAP.

Endotracheal Colonization and Ventilator-associated Pneumonia in Mechanically Ventilated Patients according to Type of Endotracheal Suction System (기관 흡인술 유형에 따른 인공호흡기 적용 환자의 기관 내 균집락화와 폐렴 발생률)

  • Cha, Kyeong-Sook;Park, Ho-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • Purpose: This study was conducted to identify endotracheal colonization and the incidence of ventilator-associated pneumonia related to the type of endotracheal suction system. Methods: The participants in this study were ICU patients hospitalized between October 2009 to March 2010 who used ventilators for over 48 hr with closed (CSS, n=30) or open (OSS, n=32) suction systems. To standardize the pre-intervention suction system, a suctioning protocol was taught to the ICU nurses. Collected data were analyzed using ${\chi}^2$-test, Fisher's exact test, Wilcoxon rank sums test, Wilcoxon test, Log-rank test and Poisson regression. Results: Endotracheal colonization was higher in OSS than CSS from day 1 to day 8 while using a ventilator and there was a significant difference between the two groups. The CSS reached 50% of endotracheal colonization by the 4th day, whereas for the OSS, it was the 2nd day (p=.04). The incidence of ventilator-associated pneumonia showed no significant difference. Conclusion: For patients with a high risk of pneumonia, CSS must be used to lower endotracheal colonization.