• Title/Summary/Keyword: clo value

Search Result 43, Processing Time 0.02 seconds

Physiological Responses and Subjective Sensations by Clo Values at -10℃ (환경온도 -10℃에서 Clo값에 따른 인체 생리반응 및 주관적 감각)

  • Kim, Ji-Yeun;Song, Min-Kyu;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.12 no.4
    • /
    • pp.531-537
    • /
    • 2010
  • The purpose of this study was to review physiological responses and subjective sensations in the cold environment when the subjects wore ensemble with different clo values. Seven healthy male subjects participated in this experiment. This experiment was conducted in a climatic chamber with $-10^sC$ and 50%RH. Subjects wore five different kinds of ensemble[C1 (4.453 clo), C2 (3.452 clo), C3 (2.865 clo), C4 (2.387 clo), and C5 (2.280 clo)]. The experiment was composed of 20 min of rest period, 20min of treadmill exercise(6 km/h) period, 30 min of recovery period. We monitored skin temperature on 7 sites, clothing microclimate and subjective sensations. The clo value had positive correlations with mean skin temperature and clothing microclimate. The subjects feel more warm and humid as the clo value goes up. The subjects reported comfort when they wore C1 and C2 ensemble having over 3 clo value. However, they felt less comfortable during the exercise period since there was high humidity. Skin temperature on the extremities were more dramatically changed by the exercise rather than clo value. Thus it seems that in the cold environment, heat balance can mostly be controlled by the choice of clothing, and the clothes with high clo values can provide higher insulation. In conclusion, our findings suggest that it would be more effective to control clo value depending on the activity level for maintaining comfort level in the cold environment.

Physiological Responses of Cold Protective Clothing with Different clo Value (보온력 차이에 따른 방한복 상의의 인체착의 생리반응)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

The Evaluation of Thermal Properties of Pesticide Protective Clothing using the Surface Temperature Controlled Thermal Manikin (열 마네킹을 이용한 부직포 농약 방호복의 열적 성능 평가)

  • Choi, Jong-Myoung
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.119-127
    • /
    • 1998
  • The purpose of this study was to evaluate thermal properties of pesticide protective clothing made of three different nonwoven fabrics which have barrier properties of pesticide. In order to assay the thermal properties of experimental clothing, thermal resistance measurements for clo value and thermographic assessment were conducted using a surface temperature controlled thermal manikin. The thermal manikin was dressed with underwear and experimental clothing. Air temperature in a climate chamber was kept at $28^{\circ}C$ and its humidity was 70% RH. Air velocity was controlled at less than 0.15m/s. Inner radient temperature was almost equal to the air temperature. The basic thermal insulation value(Icl) of underwear was 0.28 clo. The thermal properties of the experimental clothing were varied according to the type of material used in construction. The basic clothing insulation value for C1(spunbonded nonwoven fabric), C2(spunlaced nonwoven fabric), C3(SMS nonwoven fabric) were 0.705 clo, 0.725 clo, 0.738 clo respectively. The C3 experimental clothing made of SMS resulted in higher surface temperatures than the others with more yellowing spots being evident on the thermogram.

  • PDF

A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value (착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구)

  • Lee, Chul-Sung;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions - (한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 -)

  • Song, Min-Kyu;Kwon, Seo-Yoon;Jung, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.14 no.4
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.

The Diagnostic Usefulness of Endoscopic Findings and Detection Rates of CLO and HpKit Test for Helicobacter pylori Infection in Children (소아의 Helicobacter pylori 감염에 있어서 위내시경 소견의 진단적 의의와 CLO 및 HpKit 검사의 검출률)

  • Lee, Seung Yeon;Yoo, Ji Hyung;Chung, Ki Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.482-488
    • /
    • 2002
  • Purpose : We performed this study to evaluate the diagnostic usefulness of endoscopic finding of nodular gastritis, CLO and HpKit test for H. pylori infection in children. Methods : Gastroduodenal endoscopy and mucosal biopsy were performed on 212 children who visited our hospital between Jul. 1999 and May 2000 due to abdominal pain. We performed CLO and HpKit test for H. pylori with the time interval of 15, 30 minutes, 1, 2, 3, 24, 48, 72, 96, 120 and 144 hours. Histological examination of H. pylori was made by H-E or Alcian yellow stain with biopsy specimens. Sensitivity, specificity, positive predictive and negative predictive value of nodular gastritis, CLO and HpKit test were calculated from the analysis of above data. Results : Sensitivity and specificity of 3 hour-CLO test was 68.4% and 100% respectively. Sensitivity and specificity of 3 hour-HpKit test was 65.8% and 100% respectively. No significant difference in sensitivity and specificity was found between in 3 hour-CLO and HpKit test(P>0.05). Sensitivity of CLO test increased as time lapsed, but corresponding specificity did not decrease as time lapsed(sensitivity and specificity at 144 hours : 89.5% and 94.8% respectively). However, sensitivity of HpKit test increased as time lapsed, but specificity markedly decreased. Sensitivity and specificity of the nodular gastritis was 78.9% and 93.7% respectively. Conclusion : Both CLO and HpKit test have relatively low sensitivity and specificity for the detection of H. pylori in 3 hours of testing in children. The endoscopic finding of nodular gastritis is another good standard in the diagnosis of H. pylori infection in children.

Clinical Usefulness of 14C-Urea Breath Test for the Diagnosis of H. pylori Infection (H. pylori 감염 진단 시 14C-요소호기검사의 임상적 유용성)

  • Kim, Yoon-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.271-276
    • /
    • 2007
  • Helicobacter pylori (H. pylori) infection is common in korea and high incidence at gastric ulcer and duodenal ulcer. $^{14}C-urea$ breath test ($^{14}C-UBT$) is regarded as a highly reliable and non-invasive method for the diagnosis of H. pylori infection. The purpose of this study was to evaluate the diagnositc performance of a new and rapid $^{14}C-UBT$, which was equipped with Geiger-Muller counter and compared the results with those obtained by gastroduodenoscopic biopsies (GBx). One hundred sixty-eight patients (M : F = 118 : 50) underwent $^{14}C-UBT$, rapid urease test (CLO test), and GBx. The results of $^{14}C-UBT$ were classified as positive (>50 cpm), borderline (25$^{14}C-UBT$ or CLO test results with GBx as a glod standard. In the assessment of the presence of H. pylori infection, the $^{14}C-UBT$ global performance yielded positive predictive value, negative predictive value and accuracy of 93.3% and 83.3%, respectively. However, the CLO test had performance yielded positive predictive value, negative predictive value and accuracy of 76.9%, 50.0%, respectively. In this study $^{14}C-UBT$ is a highly accurate, simple and non-invasive method or the diagnosis of follow up H. pylori infection.

  • PDF

Clinical Usefulness of Helicobactor pylori Ag Stool Test (Immunochromatographic Assay) for Diagnosis of H. pylori Infection (Helicobacter pylori 감염진단에 있어 H. pylori Ag Stool 검사 (면역크로마토그라피법)의 임상적 유용성)

  • Seo, Seol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.1
    • /
    • pp.38-45
    • /
    • 2010
  • The aim of this study was to assess the Clinical Usefulness of Helicobacter pylori Stool Antigen (HpSA) immunochromatographic assay for the diagnosis of H. pylori infection. In this study, we had compared HpSA-immunochromatographic assay with CLO test and UBT test. From a total of 140 patients (M:F=88:52) with upper endoscopy, biopsy specimens were obtained for CLO test. Stool specimens was collected from all patients and tested using a HpSA-immunochromatic assay. H. pylori infection status was defined as infected if the results of both CLO test and UBT test were positive. CLO test and UBT test findings showed that 92 patients were H. pylori positive and 48 patients were H. pylori negative. According to this definition, the sensitivity, specificity, and positive or negative predictive value (PPV, NPV) of HpSA-immunochromatographic assay were 97.8%, 100%, 100%, and 96%, respectively. Cross reactivity test of HpSA-immunochromatographic assay were performed with 10 enteric bacteria strains in fecal habitat, and there were no false positive reaction. We evaluated the usefulness of HpSA assay for eradication therapy with 10 of 92 H. pylori positive patients, positive results of them at pre-eradication therapy were converted to negative at post-eradication. The HpSA-immunochromatographic assay is a highly sensitive and specific non-invasive diagnostic method for detection of H. pylori infection, a useful diagnostic method for H. pylori in post eradication stage.

  • PDF

Designing New Hanbok Products Using Saekdong -Using with CLO 3D- (색동을 활용한 신한복 제품의 디자인 개발 -CLO 3D 프로그램을 활용하여-)

  • Heeyoung Kim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.6
    • /
    • pp.945-962
    • /
    • 2022
  • This study examines the use of traditional patterns by new Hanbok brands. A Saekdong print pattern based on previous research was developed and applied to clothing designs. A total of 488 images of printed products from the seven new Hanbok brands and 219 images from the collections of the National Folk Museum of Korea were analyzed. Traditional patterns accounted for 47.4% of the total printed products of the new Hanbok designs, with the following ratio of use, in descending order: flower patterns, traditional paintings, animals, geometrical designs, Dancheong, text and others, Jogakbo, and Saekdong. Saekdong was found in three brand products, and the color or shape was modified. To develop the Saekdong image, five colors - red, yellow, blue, white, and green - were selected. The ratio of use for each color and the width of each color were determined with reference to previous studies. The average color value was determined through color analysis of the Saekdong collections. A total of seven items were designed for the print pattern, and four items were added for coordination to consist of four styles. This study aims to use the results of this analysis to provide insights into product development using traditional patterns.

Building up the foundation for the elderly apparel industry through the development on shirt sloper of elderly obese males - Applying CLO 3D program - (노년 비만남성의 셔츠원형 개발을 통한 실버 의류산업 활성화 기반 구축 - CLO 3D 가상착의 시스템 활용 -)

  • Seong, Ok jin;Kim, Sook jin
    • The Research Journal of the Costume Culture
    • /
    • v.28 no.3
    • /
    • pp.299-312
    • /
    • 2020
  • The purpose of this study is to create a shirt sloper suitable for an elderly male body shape by producing virtual models using a 3D-virtualization program, making a torso prototype using the Yuka CAD system, and employing 3D simulation to virtualize and calibrate the model. First, the following three types of obese dummies are implemented through the CLO 3D program: Type 1 exhibits body fat in the lower body; Type 2 exhibits an obese abdomen; and Type 3 displays a balanced form of obesity. Second, for the design of the shirt pattern, the waist back length (measured value+1), back armhole depth (C/10+12+3+0.5~1.5), front armhole depth (back armhole depth 0~1), front interscye (2C/10-1+0.5-0.5), armscye depth (C/10+2+3.5+ 0.5), back interscye (2C/10-1+1), front chest C (C/4+2.5+1), back chest C (C/4+2.5-1), front hem C (C/4+2.5+1(+2)), back hem C (C/4+2.5-1(+2)), cap height (AH/3-5), and biceps width (Front AH-1, Back AH-1) are calculated. Third, the virtual attachment of the shirt pattern is resolved by increasing the front and back armhole depths, and the front and rear wrinkles are improved by adding a back armhole dart. The front hem lift and lateral pull caused by the protrusion of the abdomen are amended by increasing the margin of the chest, waist C, and hip C, with the appearance improved by balanced margin distribution in the front, back, and side panels. The improved retail pattern with an increase in the front armholes C was balanced on the torso plate.