• Title/Summary/Keyword: clinical measurement

Search Result 1,820, Processing Time 0.027 seconds

An Empirical Study of the Analytical Measurement Range in Clinical Chemistry (분석측정범위의 실증적 평가)

  • Chang, Sang-Wu;Lee, Sang-Gon;Kim, Young-Hwan;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok;Lyu, Jae-Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

Statistical Analysis of Clinical Nursing Competency and Self-Efficacy in Nursing Students

  • Hong, Jeongju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.8
    • /
    • pp.123-131
    • /
    • 2018
  • The purpose of this study is to investigate the clinical nursing competence and self-efficacy of 4th and 2nd semester nursing college students who completed most of the performance-based nursing education curriculum. It was attempted to develop competency evaluation and competency-based curriculum. The collected data were analyzed using descriptive statistics, t-test, one-way ANOVA, $scheff{\bar{e}}$ test, Pearson's correlation coefficients and Stepwise multiple regression in SPSS WIN 24.0 program. The findings of this study were as follows. 1) The knowledge level of essential basic nursing skills received a score of 88.95. The overall average score of clinical performance was 3.15 out of 5. The mean score of self-efficacy was $4.14{\pm}0.57$ points on 6 points 2) Among the general characteristics of subjects, 'motivation of major selection' and 'satisfaction of practice time' differed in the knowledge of essential basic nursing skills, 'religion' and 'health status' differed in clinical performance ability and 'interpersonal relationship', 'motivation of major selection', 'major satisfaction', 'satisfaction of practice time', 'nursing satisfaction', 'desired working period' and 'average rating' differed in self-efficacy. 3) The self-efficacy showed a significant positive correlation with the clinical nursing competency including the knowledge of essential basic nursing skills and clinical performance ability. The nursing satisfaction, clinical performance ability, the knowledge of essential basic nursing skills, interpersonal relationship and average rating influenced significantly and explained 23.7% of the subjects' self-efficacy.

Study on the Latest Trends of u-Health and Relations of Medical Technologist

  • Sung, Hyun-Ho;An, Yong-Ho;Lee, Dong-Beom;Kim, Sang-Won;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.4
    • /
    • pp.178-183
    • /
    • 2012
  • We investigated the latest trend of u-Health and relations with clinical technologist. Since 2000, Korea has become an aging society. Korea will become an aged society by 2018, and it is expected to enter the ultra-high aged society by 2026. Increase in over 65 years population means that the desire of medical service and care demand for the elderly is greatly required. In addition, many predicted Korean national health insurance would falter financially. Medical suppression policies and regulations are also amended continuously. U-Health based on the IT industry and development of related technologies and industries contains the variety concepts of telemedicine, telehealth, e-health, u-healthcare and POCT. Especially, the use of POCT supplied quick clinical examination is extending steadily in medical center and hospital, which will generate the field friction between nurses and medical technologists. In the transition situation from provider-centric service to consumer-driven health care system, this study recommended the principal role and correspondence of clinical laboratory workers and offered information about changes in healthcare market and the basic concept of expert system, measurement and the diagnosis principle to clinical technicians throughout the investigation of the recent research and government policy trends.

  • PDF

Nursing Students' Hearing Levels and Blood Pressure Measurement Accuracy (간호대학생의 청력수준과 혈압측정의 정확도)

  • Kim, Heeyoung;Chung, Young Hae;Kim, Yun Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.3
    • /
    • pp.275-282
    • /
    • 2016
  • Purpose: This study was done to examine the relationship between nursing students' hearing levels and accuracy of blood pressure (BP) measurements. Methods: Participants were 107 students who had finished their fundamental nursing practice and clinical practicum and who used earphones. Data were collected from October 13 to November 30, 2014 and from April 30 to May 19, 2015. Students' hearing thresholds were examined using an audiometer. Students were assigned to take two BP measurements on BP measurement training simulators, but only the second measurement was used for analysis. Results: All nursing students' hearing levels were within normal range, and there was no significant difference found among the settings for diastolic blood pressure. However, there were significant differences between low systolic blood pressure (SBP) (below 120mmHg) and high SBP (over 140mmHg) (z=9.02, p=.011). Measurement error in SBP showed a positive correlation with hearing threshold in the right ear at frequencies of 1000Hz and 500Hz. Conclusion: Findings indicate that BP measurement error is correlated with hearing threshold at some frequencies. To reduce measurement error, nursing students should be provided with health education about hearing and to improve training for students, further studies need to examine other factors influencing BP measurement error.

The Current Status and Requirements for Non-pharmacological Treatment of Depression in Korea (한국에서 우울증의 비약물학적 치료의 현황과 요구도)

  • Oh, Hong Seok;Lee, Hae Won;Park, Yong Chon
    • Korean Journal of Biological Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2007
  • Objectives : As a part of plan to develop evidence-based treatment guidelines for depression that is more suitable for Korean situation, we investigate the present status and client's requirements for non-pharmacological treatment of depression in Korean clinical situation. Methods : Subjects were patients with depression in 12 university hospitals which are located in metropolises in Korea. We analyzed the records from questionnaires about current clinical status and requirements for the non-pharmacological treatment of depression in Korea. Results : 50.8% of the subjects have experienced non-pharmacological treatments for their depression. The preference of non-pharmacological treatment method of depression is exercise/interesting activity, counseling by psychiatrists and psychotherapy, and the best effective treatment method is psychotherapy (Es=4.36). Actually, the mean consultation time by psychiatrist is $11.31{\pm}7.16$ min, and the appropriate consultation time for client's situation is $18.39{\pm}8.95$ min. During consultation, patients' satisfaction measurement for psychiatrist's explanation about pharmacological treatment is $64.17{\pm}27.11$, and satisfaction measurement for psychiatrist's counseling for their depression about personal problems, resent stress, interpersonal relationship is $61.66{\pm}26.63$. Conclusion : In Korea, many psychiatrists offered biologically oriented treatment to their patients with depression, and patients' satisfaction measurement about consultation by psychiatrists is low. Many patients wanted to combined pharmacological and non-pharmacological treatment for their depression, and aspired to information about complementary and self-help treatment methods. It is necessary to develop non-pharmacological treatment guideline for depression which reflect the clinical situation in Korea and meet Korean patients' need.

  • PDF

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

Clinical and Histopathological Study Using Platelet Rich Plasma and Bone Grafts in Extraction Sockets (발치와의 혈소판 농축 혈장과 골 이식술 시행시 골 형성에 대한 임상 및 조직병리학적 연구)

  • Jeon, Young-Tae;Chung, Chin-Hyung;Lee, Chong-Heon;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.437-449
    • /
    • 2001
  • The socket preservation procedure was a simple and effective technique, and has better prognosis for implantation. The socket preservation usually used barrier membrane in combination with/without alloplastic bone materials. A recently study had shown that a regenerative therapy to tooth extraction utilizing growth factors made better results. Platelet-rich plasma was clinically easy method that acquired the growth factors, and is known that accelerated new bone formation and mineralization of bone graft materials. The purpose of this study was to evaluate clinical and histopathologic results which occur following socket preservations using platelet-rich plasma and bovine bone powder. Twelve patients who required extraction of one or more teeth for implantation at the department of periodontics in Dankook University Dental Hospital were selected. Extraction sockets were treated by using platelet-rich plasma and bovine bone powder. 3 months later, we observed clinical and histopathological results as follows: 1. Internal vertical measurement was an average of 7.33mm preoperatively and statistically significantly decreased to an average of 1.42mm postoperatively(p<0.05). 2. External vertical measurement was an average of 3.33mm preoperatively and decreased to an average of 2.75mm postoperatively; therefore there was no significant difference. 3. Horizontal measurement was an average of 7.75mm preoperatively and statistically decreased to an average of 6.08mm postoperatively(p<0.05). 4. Osteocyte-like cells and new bone formation connected with bovine bone grafts were observed in histopathologic examination. This study implied that platelet-rich plasma and bovine bone powder grafts were effective treatment for socket preservation and regeneration of severe bony defect made by implantation failure.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

A Review on Clinical Research of Acupuncture Using Electroencephalogram (뇌파를 평가도구로 사용한 침 중재 임상연구 동향)

  • Lim, Jung-Hwa;Cho, Jun-Hee;Kim, Jae-Hyo;Kim, Lakhyung;Kang, Hyung-Won;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.32 no.4
    • /
    • pp.345-378
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the recent trends of clinical research on acupuncture using electroencephalogram (EEG) as the outcome measurement. Methods: Nine domestic and foreign databases were searched to collect related studies published up to November 3, 2021. The participants, intervention, outcomes, results of the included studies were extracted and analyzed. Results: A total of 18 studies were selected. Neurological diseases and mental disorders were included in most studies, and vascular dementia were most frequently investigated. Electroacupuncture and body acupuncture intervention were most frequently conducted in seven studies. The most commonly used outcomes using EEG was EEG abnormality. However, in most studies there was accurate description of the EEG measurement. Most studies showed significant difference in EEG outcomes after intervention. The quality of included studies was poor. Conclusions: EEG as diagnostic markers and outcome measurements is increasingly studied. Standardized EEG measurement and the consistent EEG finding for specific diseases are needed to perform the future rigorous studies on EEG as diagnostic and outcome tools.

An Analysis on Clinical Education of Pediatric Nursing (아동간호학 임상실습교육 현황)

  • Kwon In-Soo
    • Child Health Nursing Research
    • /
    • v.8 no.3
    • /
    • pp.344-356
    • /
    • 2002
  • This study was conducted to analyse the current clinical education of pediatric nursing in baccalaurate nursing program, then to give basic data for enhancing the quality of future clinical education of pediatric nursing. Data were collected through self-reported questionnaire by mail from December 2001 to February 2002. The subjects were 29 schools of 50 baccalaurate nursing education programs. The data were analysed by double raters, researcher and assistant researcher. The results were summarized as follows: 1. Twenty-eight schools had the objectives of the clinical education of pediatric nursing, and 28 schools in pediatric ward, 23 schools in nursery, 22 schools in neonatal intensive care unit(NICU), 15 schools in objectives related to profession by clinical site. 2. Credits on clinical education of pediatric nursing were most 15 schools of 3 credits. 3. The clinical sites were mainly the hospital that sick children were admitted in. 4. The clinical teacher were 9 types including pediatric professor and field nurse. 5. On teacher's role, the professor instructed the case study and conference, and field nurse instructed the patient assignment and nursing procedures. 6. All of schools used explanation and conference as a method of clinical education, 1 or 2 schools used PBL or role play or field study. 7. On clinical education content, most of school included Apgar scoring system, physical examination in newborn assessment, respira- tion maintenance, temperature maintenance, infection prevention, nutrition, and bath in newborn care. 8. On clinical education content, most of school included care of incubator, phototheraty, infusion, gavage feeding and how to use the instruments in NICU. Eighteen schools included attachment promotion, and 20 schools case study. 9. On clinical education content, most of school included a checklist of nursing procedures, case study, assessment of growth and development in pediatric ward and other sites. 10.There were various evaluation types in scores, measuring items. In conclusion, the results of this study revealed that there were some discrepancy in the objectives and contents, clinical sites on hospital focused, teacher's role, and diversity of measurement items and ratings in clinical education of pediatric nursing. There is a need for a standardization of content, clinical site, and evaluation tool to improve a quality of clinical education of pediatric nursing based on this study.

  • PDF