• Title/Summary/Keyword: climate system

Search Result 2,606, Processing Time 0.04 seconds

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

Past, Present and Future of Geospatial Scheme based on Topo-Climatic Model and Digital Climate Map (소기후모형과 전자기후도를 기반으로 한 지리공간 도식의 과거, 현재 그리고 미래)

  • Kim, Dae-Jun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.268-279
    • /
    • 2021
  • The geospatial schemes based on topo-climatology have been developed to produce digital climate maps at a site-specific scale. Their development processes are reviewed here to derive the needs for new schemes in the future. Agricultural and forestry villages in Korea are characterized by complexity and diversity in topography, which results in considerably large spatial variations in weather and climate over a small area. Hence, the data collected at a mesoscale through the Automated Synoptic Observing System (ASOS) operated by the Korea Meteorological Administration (KMA) are of limited use. The geospatial schemes have been developed to estimate climate conditions at a local scale, e.g., 30 m, lowering the barriers to deal with the processes associated with production in agricultural and forestry industries. Rapid enhancement of computing technologies allows for near real-time production of climate information at a high-resolution even in small catchment areas and the application to future climate change scenarios. Recent establishment of the early warning service for agricultural weather disasters can provide growth progress and disaster forecasts for cultivated crops on a farm basis. The early warning system is being expanded worldwide, requiring further advancement in geospatial schemes and digital climate mapping.

Impact of the Rice-Duck Farming System on Regional Agricultural Environment at Hongsung Area (오리농법에 의한 벼 재배가 지역 환경에 미치는 영향 평가)

  • Roh, Kee-An;Kim, Min-Kyeong;Ko, Byong-Gu;Kim, Gun-Yeob;Shim, Kyo-Moon;Jeong, Hyun-Cheol;Lee, Deog-Bae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.spc
    • /
    • pp.57-61
    • /
    • 2009
  • To clarify the impact of the rice-duck farming system on the regional environment and the surrounding, a case study was carried out at Hongdong Reservoir valley of Hongdong-myeon and Janggok-myeon, Hongseong-gun, Chungcheongnam-do where the density of livestock grazing is the highest and rice cultivation with the rice-duck farming system is extensively practiced. The soil characteristics and water qualities at paddy fields were compared between two rice cultivation methods of rice-duck farming system and conventional farming system. The organic matters and available phosphate contents in soil of paddy fields where the rice-duck farming system was practiced were higher than those of paddy fields where conventional farming system was practiced. However, the available phosphate content was lower than the optimum for rice cultivation and the mean concentration of paddy soil in Korea. The surface water quality of the paddy field with the rice-duck farming system was practiced had higher EC (137 %), $COD_{Cr}$ (220 %), T-N (172 %), and T-P (226 %) contents than that with the conventional farming system was practiced. Especially, $COD_{Cr}$ and T-P were more than 2 times higher, which tells that the possibility of water pollution by drainage water of paddy field is higher in the paddy fields with the rice-duck farming system practiced than in those with the conventional farming practiced. The higher contents of T-P and $COD_{Cr}$ in surface water at the paddy field of rice-duck farming system practiced were directly caused by soil particles in the muddy water. Consequently, it is necessary to thoroughly manage the irrigation and drainage system of rice-duck farming system practiced to prevent outflow of surface water from paddy and pollution of surrounding water system.

Study on the Optimum Design of a Heat Pump System Using Solar and Ground Heat (태양열 및 지중열원을 이용한 히트펌프 시스템의 최적이용법에 관한 연구)

  • Nam, Yu-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.509-514
    • /
    • 2012
  • In this research, a heat pump system with a heat source network is suggested which utilizes solar heat and ground heat as heat source for cooling and heating. This paper describes the summary of the suggested system and the results of the annual energy simulation. The heating and cooling loads, the electric consumption and the COP were calculated by TRNSYS 16 and evaluated in the cases of different local conditions and different system compositions. In the results, the superiority of the suggested system has been quantitatively evaluated comparing with the conventional heat pump system using one heat source. Furthermore, it was more significant in cold climate, in which the heating COP was 146% increased compared the air source heat pump system, than it in subtropical climate, 119% increased.

The relationship between safety climate and safety participation in construction industry (건설업 근로자들의 안전분위기와 안전참여의 관계에 대한 연구)

  • Ahn, Kwan-Young;Park, Roh-Gook
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.6
    • /
    • pp.41-53
    • /
    • 2006
  • Safety climate in the research area of industrial safety begins to be influential meta-theory. With this research trend, this paper is to examine the relationship between safety climate and safety participation, and the moderating effect of age. Data were gathered from 292 manufacturing workers in construction industry. It is found that management involvement, safety education, and precaution activities have affirmative effect on safety participation, and physical job load negative effect on it. Next, education, precaution activities, and safety system were found to have interactional effects on safety participation with age.

Climate Elasticity of Korean Streamflows (기후변동에 대한 한국 하천유량의 탄력성)

  • Jung, Il-Won;Chang, Hee-Jun;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.851-864
    • /
    • 2010
  • We investigated the sensitivity of Korean streamflows to climate variation. Historical dam inflows and climate data for eight multi-purpose dam sites were collected and examined to determine key factors affecting streamflow change. The results show that annual streamflow primarily responds to change in precipitation rather than temperature. However, the combination of less precipitation and high temperature induces a more serious decrease in streamflow than does similar precipitation and with low temperature. This result indicates that Korean water resources could be more vulnerable to drought due to increasing temperature caused by global warming. To estimate spatial differences in climate sensitivity, we also calculated climate elasticity for 109 mid-size watersheds using streamflow simulated by the Precipitation Runoff Modeling System (PRMS). Climate elasticity ranges over 1.5~1.9, indicating that a +20% increase in annual precipitation leads to a +30~+38% increase in annual streamflow.

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

A Review of Observed Climate Change in Korean Peninsula (한반도 지역 관측 기후변화 고찰)

  • Ho, Chang-Hoi;Lee, Min-Hee;Park, Tae-Won;Lee, Seungmin
    • Journal of Climate Change Research
    • /
    • v.2 no.4
    • /
    • pp.221-235
    • /
    • 2011
  • This study summarizes previous studies on the climate change over Korea. Several studies on climate change in the neighboring countries as well as the entire globe are reviewed. Temperature data obtained from modern observational system show an increasing trend beyond the natural variations. The increasing rate of sea surface temperature (SST) over the ocean basins surrounding Korea is higher than that of the global-mean SST. The large increase in the SST over the oceans surrounding Korea may enhance tropical cyclone activity and heavy rainfall frequency in Korea. In addition, it has been reported that the changes in large scale circulation associated with global climate change influence the spatio-temporal variation of monsoon including Changma in summer and cold surges in winter. Although all researches on the subject were not fully discussed in this study due to short period of preparation, allowed pages, and authors' limited knowledge, we expect that this summarized reviews would be helpful to understand climate changes over Korea and the surrounding regions.

Validity and Reliability of the Korean Version of the Climate, Health, and Nursing Tool (한국어판 기후 건강관련 간호사 인지행동 측정도구의 타당도와 신뢰도)

  • Jeong, Da Woon;Kim, Gwang Suk;Park, Min Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.52 no.2
    • /
    • pp.173-186
    • /
    • 2022
  • Purpose: Climate change has various negative effects on human health, which has resulted in increased burden on the health care system. Nurses contribute significantly to assessing climate-related health risks and creating a healthy environment. This study aimed to evaluate the reliability and validity of the Korean version of the Climate, Health, and Nursing Tool (K-CHANT) to measure nurses' awareness, motivation, concern, and behaviors at work and at home regarding climate change and health. Methods: The 22 items of English CHANT were translated into Korean with forward-backward translation techniques. Internal consistency reliability, test-retest reliability, and construct validity using confirmatory factor analysis were performed using SPSS WIN (25.0) and AMOS (26.0). Survey data were collected from 220 master's, doctoral, and post-doctoral nursing students. Results: The K-CHANT consists of 20 items across 5 domains. Two items of the original CHANT were excluded because of low content validity index and standardized regression weights. The internal consistency reliability of the K-CHANT, assessed by Cronbach's α was .81, with an intraclass correlation coefficient of .66~.90. The five subscales model was validated by confirmatory factor analysis (SRMR < .08, RMSEA < .08, AGFI > .70, CFI > .70). Conclusion: The K-CHANT has satisfactory construct validity and reliability to measure nurses' awareness, motivation, concern, and behaviors at work and at home regarding climate change and health. Future research should examine nurses' perceptions and behaviors related to the health effects of climate change and develop an action plan to improve it.