• Title/Summary/Keyword: cleaning methods

Search Result 485, Processing Time 0.023 seconds

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

Alteration of Physical and chemical Characteristics of Waterlogged Archaeological Woods After Cleaning (세척 후 수침고목재의 물리.화학적 특성 변화)

  • Cha, Mi-Young;Lee, Kwang-Ho;Kim, Yoon-Soo
    • Journal of Conservation Science
    • /
    • v.19
    • /
    • pp.19-30
    • /
    • 2006
  • Alteration of physical and chemical characteristics and the effect of removal of mineral substances in waterlogged archaeological woods by different cleaning processes were examined using oak wood(Quercus spp.) that was excavated from wetland near Gwangju, Korea. Cleaning methods employed in the present work were (1) tools, (2) deaeration, (3) EDTA and (4) ultrasonic cleaning, which are being currently applied in the field of preservation treatment. Cleaning process were performed independently or continuously. Composition of mineral substances in the waterlogged archaeological wood was almost same as the that of soil in which waterlogged archaeological woods were buried. In case of independent cleaning, tools cleaning efficiently removed the mineral substances on surface. Surface color become brighter after cleaning with EDTA. In contrast, deaeration and ultrasonic cleaning did not show any significant removal of mineral substances. In continuous cleaning process, tool cleaning as the first step treatment showed the same effect as shown in independent cleaning. Although deaeration as the second step cleaning did not remove the mineral substances, it could be assumed to contribute the infiltration of dimensional agents by homogenization of wood. EDTA treatment (the third step cleaning) removed the iron(Fe) and increased the whiteness of wood color. The ultrasonic treatment (the fourth step cleaning) removed the sodium(Na) remained after EDTA treatment and the fine mineral substances.

  • PDF

A Study on the Evaluation Methods of Residual Flux Cleaning Ability by Alternative Semi-Aqueous Cleaners Using Metal Test Tools After Soldering with Solder Paste (솔더페이스트로 솔더링 후 잔류 플럭스 오염물에 대한 준수계 세정제의 금속치구를 이용한 세정성능 평가방법 연구)

  • Lee, Dong-Kee
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.103-109
    • /
    • 2008
  • In this study, in order to develop evaluation method of the cleaning efficiency of residual flux which remains on the surface after soldering with solder paste, a specially designed metal tool is used to reduce spread uncertainty of flux while soldering. Using this tool, the measurement of cleaning efficiency of flux after soldering for some typical alternative semi-aqueous cleaners and 1,1,1-TCE by weighing method was conducted. As the test result of cleaning efficiency for each cleaner at several different cleaning times, the precision of the data is confirmed to within about 4% relative standard deviation (RSD) range. So, it is considered that this would be a good evaluation method for evaluating the cleaning efficiency of the residual flux which remains after solder paste soldering in the alternative cleaning. The results of this test method shows that the cleaning efficiency of ST 100SX and Neozal 750H in the cleaning of residual flux was better than other semi-aqueous cleaners, but its cleaning efficiency was clearly inferior to 1,1,1-TCE.

  • PDF

Study on the Effect of Surface Finishing Methods on Pitting Corrosion Behavior of 304 Stainless Steel Alloy

  • Yun, JunTae;kim, Se-Woong;Hwang, HyangAn;Toor, Ihsan-Ul-Haq;Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.209-216
    • /
    • 2009
  • In this study the effect of different surface finishing techniques on the pitting corrosion behaviour of a commercial 304 stainless steel alloy was investigated. Surface finishing methods were divided into two categories, i.e. mechanical and chemical. Mechanical treatment methods include power tooling such as grinding, emery paper brushing, stainless steel wire brushing and stainless steel shot blasting. Chemical treatment methods include chemical passivation (phosphoric acid, citric acid, nitric acid) and electro-cleaning (phosphoric acid and citric acid). Potentiodynamic polarization experiments were carried out in 3.5 wt. % NaCl solution at room temp. (20 $^{\circ}C$). The results showed that chemical treatment methods improved the corrosion resistance of stainless steel 304, measured in terms of pitting potential ($E_{pit}$). Corrosion resistance of the specimens was increased in the order of; electro-cleaning > manual passivation > mechanical cleaning. Surface of electro-cleaned specimens was smoother than rest of the surface treatment methods. Chrome content in chemically treated specimens was higher than in mechanically treated specimens as shown by EDX analysis.

Business Model Development of Facade Cleaning Robot (건물 외벽청소 로봇의 비즈니스 모델 개발)

  • Seo, Hyeon-Yeong;Choi, In-Hugh;Cho, Young-Jo;Sim, Min Kyu
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.381-386
    • /
    • 2022
  • We develop a business model for facade cleaning service robot system that provides service by meeting the market needs and environments. The size of the facade cleaning market is growing rapidly in recent years due to the increasing importance of indoor space and the modern trend of building construction methods. Also, maintenance of exterior appearance of buildings has become an important factor in residential and commercial facilities. Though demand for facade cleaning services is rising, the current facade cleaning services are performed dangerously in a human labor-dependent way. It is desirable that the existing human resource service should be replaced with robot-based services. In addition, quantitative analysis of rental pricing model was conducted to propose effective launch of products to the market. The robot system is economically attractive from the consumer's point of view. When the actual facade cleaning robot service is released, it is expected that verification of the business models and more accurate analysis with specific figures can be performed.

A Study on Dry Cleaning Mechanism for End-of-Life CRT (폐CRT 건식 세정메커니즘에 관한 연구)

  • 송준엽;강재훈;이승우;이화조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.415-419
    • /
    • 2002
  • In this study, we suggest a environmentally-conscious and dry cleaning process mechanism for the recycling of end-of-life CRT, and also develope a protype cleaning system to verify the faulty of the designed mechanism. This system accommodates the specifications of 14 ~ 32" end-of-life CRT. In experimental result, it is expected that the developed system improve the productivity up to 10% and decrease the loss rate of cleaning glass 3~4 times rather than the existing methods.hods.

  • PDF

Environmentally-Conscious Cleaning System for End-of-Life CRT (환경친화적 폐브라운관 세정시스템 개발)

  • 송준엽;강재훈;허성필;이화조
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.126-134
    • /
    • 2003
  • In this study, we suggest a environmentally-conscious and dry cleaning process mechanism for the more useful recycling of end-of-life CRT, and also develop a prototype cleaning system to verify the faulty of the designed mechanism. This system accommodates the specifications of 14∼32" end-of-life CRT. In experimental result, it is expected that the developed system improve the productivity up to 10% and decrease the loss rate of cleaning glass 3∼4 times than the glass blasting methods.

A Study on Dyes Solubility of Dry cleaning Solvents (드리아 클리닝 용제에 대한 염료의 용해성)

  • Cha, Ok-Sun;Shin, Jung-Sook
    • Textile Coloration and Finishing
    • /
    • v.2 no.3
    • /
    • pp.43-50
    • /
    • 1990
  • The purpose of this paper is to investigate the dyes solubility of dry cleaning solvents among the current domestic products. The dyes were experimented in following way; 1) The flow rate of dyes by paper chromatography method. 2) The color difference & the absorbance of solvents between the dyed fabrics before and after dry cleaning. From the experiment, following results were obtained. 1. In paper chromatography methods, the flow rate of dyes in the disperse dyes was bigger while flow was not shown in the direct dyes & acid dyes. 2. The more the number of times on dry cleaning in dyed fabrics was, the higher the absorbance of solvents was shown. The results were showed following order, PerchloroethyleneHydrocarbon> Fluorocabon. 3. The color difference between before & after dry cleaning on dyed fabrics showed bigger in disperse dyes.

  • PDF

Detergency improvement of hydrophilic soils in dry cleaning process (드라이클리닝 시 친수성 오구의 세탁성 향상을 위한 연구)

  • Kwak, Soo-Kyoung;Sang, Jeong Seon;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.213-220
    • /
    • 2019
  • The dry cleaning effect related to the type of soil and fiber was analyzed using silicone and alcohol-based solvents(ethyl alcohol, isopropyl alcohol, acetone) that are relatively safe for the human body and environment to improve the detergency of hydrophilic soils in dry cleaning system. Based on this analysis, an effective dry cleaning method to be carried out for improving the detergency according to the type of hydrophilic soils. After dry cleaning was performed using 20 types of artificial soiled fabrics consisting of 7 types of fibers and 4 types of hydrophilic soils, the detergency was measured and the results were compared and analyzed by solvents and fiber types. The results are presented as follows; first, the detergency of hydrophilic soils using silicone solvents showed a low rate of detergency. In particular, the tannin soil showed a lower level of detergency compared to the protein soil. Second, the detergency of hydrophilic soils using silicon solvents with dry soap differed in some detergency according to the soil and fiber types. Especially, the detergency of curry soil on cotton fabric showed significant improvement. Third, the protein soil was not removed from dry cleaning using alcohol-based solvents, but the effect of dry cleaning of curry soil on both cotton and polyester fabric was substantially improved. As a result, the elimination of blood soil is more effective in silicon solvents than in alcohol-based solvents. The removal of tannin soils may improve detergency by adding dry soap to silicon solvents or by using alcohol-based solvents as alternative solvents. The use of alternative solvents such as silicon and alcohol solvents can contribute to the environmental improvement of the dry cleaning industry, which uses petroleum-based solvents. It is also expected to provide consumers with the opportunity to choose eco-friendly and efficient dry cleaning methods.

Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.