• Title/Summary/Keyword: cleaning methods

Search Result 482, Processing Time 0.024 seconds

A Study on the Institutional Limitations of Chemical Exposure Control for Cleaning Workers - Focusing on the Exclusion of Preparation and Submission of Material Safety Data Sheets (청소노동자 화학물질 노출 관리의 제도적 한계 고찰 - 물질안전보건자료 작성·제출 제외 조항을 중심으로)

  • Shin, Saemi;Ki, Nosung;Lee, Hea Min;Kim, Dong Hyeon;Wee, Seohyeon;Byeon, Sang-Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.41-52
    • /
    • 2022
  • Objectives: This study intends to review the impact on cleaning workers and suggest directions for improvement by reviewing the legal and institutional ways in which Article 86 Nos. 7 and 16 of the Enforcement Decree of the Occupational Safety and Health Act work on the maintenance and promotion of cleaning workers' health. Methods: The following laws and systems were reviewed and considered: First, the occupational safety and health legislation obligated or required to be applied to protect the health of cleaning workers; Second, the status of control of chemicals or mixtures used at cleaning sites through the Consumer Chemicals Product and Biocide Safety Control Act; Third, Control of consumer products according to foreign material safety data sheet related laws. Results: Legal and institutional measures necessary to protect the health of cleaning workers include the legal control of harmful substances to be controlled, work environment monitoring, and special health examinations. The application of the Consumer Chemicals Product and Biocide Safety Control Act does not satisfy the legal and practical level of health maintenance and promotion required by the Occupational Safety and Health Act, and the communication of chemical information is insufficient. Overseas, there are restrictions on the use of consumer products in the workplace without material safety data sheets. Conclusions: It is necessary to improve the system to ensure the health of workers handling consumer chemical products. The remaining laws and regulations exempted from the obligation to prepare material safety data sheets should be additionally reviewed.

A study on the effective cleaning of healing abutment using healing abutment case (Healing abutment case를 이용한 healing abutment의 효과적인 세척에 관한 연구)

  • Kim, Hyeon-Kyeong;Cho, In-Ho;Song, Young-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose. The present study aimed to investigate the effective cleaning of healing abutment (HA) using Healing abutment case (HA case) by observing oral microorganisms with phase contrast microscope. Materials and methods. 32 patients with two or more implants placed in the same jaw, a total of 64 HAs (experimental group 32, control group 32) were selected and the control was cleaned with an alcohol swab. At the first and second visits, each group was observed before cleaning, and the experimental group was additionally observed after cleaning at the first visit. A 400× phase contrast microscope was used for the observation of oral microorganisms for its amounts. Results. There was no significant difference in the amount of oral microorganisms was found between the groups at the first visit, no significant difference according to gender, maxilla or mandible, and buccal or lingual surface. There was a statistically significant difference in the amount of oral microorganisms according to supra-gingival and sub-gingival (P<.05), There was also a significant difference in the comparison before and after cleaning in the experimental group (P<.05). There was a significant difference in the amount of oral microorganisms in each group at second visit (P<.05). Conclusion. Healing abutment cleaning using healing abutment case solution is more effective than simple cleaning with alcohol swab.

Development of a Rotation Swab Pig Method for Cleaning Water Pipes (상수관의 세척을 위한 회전식 스왑피그 공법 개발)

  • Kicheol Lee;Jaeho Kim;Kisung Kim;Jeongjun Park
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Drinking water is an essential element to ensure the basic human right to live, and the quality of clean water must always be ensured. However, domestic water facilities, which were installed intensively in the early 2000s, are deteriorating. The accidents such as discoloration of water such as chromaticity and turbidity as well as leakage of substances frequently occur. However, since it is virtually impossible to replace all water pipes, the detailed standards for maintenance of water pipe network facilities established in 2021 require water pipe cleaning. The swab pig method, one of the water pipe cleaning methods, is a method of physically removing substances in pipes and is evaluated as having the highest cleaning efficiency. However, Swab is highly likely to be damaged or deformed during the cleaning process, and may even be lost. Therefore, in this study, the material of the pig was changed to a material with high compressibility, and it was made as close as possible to the inner wall of the water pipe. And, to maximize cleaning efficiency, a rotation swab pig with a rotation blade was developed. In addition, high-strength wire and winding equipment were additionally developed to eliminate the possibility of loss and to determine the location of the pig. The inlet and outlet are connected with wires, and after verifying the performance of each detailed technology, the technology was applied on a test bed with a 30m section. As a result of the application, the performance of the technology was verified by measuring the process time and evaluating applicability.

Adequacy of Reprocessing Gastrointestinal Endoscopes in Korea Hospitals (국내 병원 소화기내시경 재처리과정의 적절성)

  • Kim, YoungOk;Jeong, Jae Sim
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.288-295
    • /
    • 2016
  • Background: This study was conducted in order to survey the current state of cleaning, disinfection, rinsing, drying, and storage of gastrointestinal endoscopes. Methods: Eighty hospitals were selected through convenient sampling. Self-reported questionnaire was distributed from September 14 to October 10 in 2015. Results: The response rate was 67.5% (54/80). In 88.9% of the hospitals, reprocessing was performed in a cleaning space separated from the laboratory and 88.9% used an enzymatic cleaner. Disinfectants used were ortho-phthalaldehyde in 63.0%, and paracetic acid in 33.3%. Eighty seven percent of the hospitals used test strips in order to test the effective concentration of disinfectant and in 61.1%, drying was done through passing air and over 70% alcohol. Microbial culture for the quality control of gastrointestinal endoscopes was performed in 77.8%. In the comparison of the adequacy of gastrointestinal endoscope reprocessing, it was observed that gastrointestinal endoscopes were reprocessed more adequately in larger and tertiary care hospitals. Conclusion: Gastrointestinal endoscopes were reprocessed in similar manners, but there were differences in the detailed process. It is still necessary to segment reprocessing into stages, to prepare standardized guidelines, and to monitor compliance with the guidelines.

Development of a Far Field type Megasonic for Nano Particle Removing (나노입자 제거용 Far Field 메가소닉 개발)

  • Lee, Yanglae;Kim, Hyunse;Lim, Euisu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1193-1201
    • /
    • 2013
  • Improved far field type(improved type) megasonic applicable to the cleaning equipment of single wafer processing type has been developed. In this study, to improve the uniformity of acoustic pressure distribution(APD), we utilize far field with relatively uniform APD, piezoelectric ceramic with a triangle hole in its center to prevent standing wave resulted from radial mode, and reflected wave from the wall of waveguide. On the basis of these methods, two analysis models of improved type were designed to which piezoelectric ceramic of different shape of electrode attached, and APD were analyzed by means of finite element method, and then one of them was selected by analysis results, finally, the selected model was fabricated. Test results show that the fabricated is better in the uniformity of APD than the imported and the conventional, also the fabricated shows high particle removal efficiency of 92.3% using DI water alone as a cleaning solution.

Development of High-Quality Poly(3,4-ethylenedioxythiophene) Electrode Pattern Array Using SC1 Cleaning Process (SC1 세척공정을 이용한 고품질 Poly(3,4-ethylenedioxythiophene) 전극 패턴 어레이의 개발)

  • Choi, Sangil;Kim, Wondae;Kim, Sungsoo
    • Journal of Integrative Natural Science
    • /
    • v.4 no.4
    • /
    • pp.311-314
    • /
    • 2011
  • Application of self-assembled monolayers (SAMs) to the fabrication of organic thin film transistor has been recently reported very often since it can help to provide ohmic contact between films as well as to form simple and effective electrode pattern. Accordingly, quality of these ultra-thin films is becoming more imperative. In this study, in order to manufacture a high quality SAM pattern, a hydrophobic alkylsilane monolayer and a hydrophilic aminosilane monolayer were selectively coated on $SiO_2$ surface through the consecutive procedures of a micro-contact printing (${\mu}CP$) and dip-coating methods under extremely dry condition. On a SAM pattern cleaned with SC1 solution immediately after ${\mu}CP$, poly(3,4-ethylenedioxythiophene) (PEDOT) source and drain electrode array were very selectively and nicely vapour phase polymerized. On the other side, on a SC1-untreated SAM pattern, PEDOT array was very poorly polymerized. It strongly suggests that the SC1 cleaning process effectively removes unwanted contaminants on SAM pattern, thereby resulting in very selective growth of PEDOT electrode pattern.

K Partition-Based Even Wear-Leveling Policy for Flash Memory (K 분할 기반 플래시 메모리 균등소거 방법론)

  • Park Je-Ho
    • The KIPS Transactions:PartD
    • /
    • v.13D no.3 s.106
    • /
    • pp.377-382
    • /
    • 2006
  • Advantageous features of flash memory are stimulating its exploitation in mobile and ubiquitous related devices. The hardware characteristics of flash memory however place restrictions upon this current trend. In this paper, a cleaning policy for flash memory is proposed in order to decrease the necessary penally for recycling of memory minimizing the degradation of performance at the same time. The proposed cleaning algorithm is based on partitioning of candidate memory regions, to be reclaimed as free, into a number of groups. In addition, in order to improve the balanced utilization of the entire flash memory space in terms of 'wearing-out', a free segment selection algorithm is discussed. The impact of the proposed algorithms is evaluated through a number of experiments. Moreover, the composition of the optimal configuration featuring the proposed methods is tested through experiments.

A Systematic Review and Meta-Analysis on the Effects of Urinary Tract Infections in the Water or Antiseptic for Periurethral Cleaning Before Urinary Catheterization (도뇨관 삽입 전 소독제 또는 물의 사용이 요로감염 발생에 미치는 효과에 대한 체계적 문헌고찰과 메타분석)

  • Kim, Jin-Sook;Kim, Mi-Jung;Kim, Kuk-Hwa;Lim, Da-Hae
    • Quality Improvement in Health Care
    • /
    • v.23 no.2
    • /
    • pp.81-94
    • /
    • 2017
  • Purpose:The purpose of this study was to evaluate the effects of periurethral cleaning with water or antiseptics in preventing catheter-associated urinary tract infections through systemic review Methods:The randomized clinical trials published between 2000 and 2016 were searched using domestic and international databases, and five randomized studies were selected for this study. The quality of study was assessed by assessment tool from the cochrane's Risk of Bias and meta-analysis was performed using the Cochrane Review Manager software Version 5.3 (RevMan) Results: The two groups of antiinfectants used in this study include povidone-iodine and chlorhexidine, water and chlorhexidine vs water and chlorhexidine. there was no significant difference in urinary tract infection rate between the two groups. Conclusion: Based on the findings, periurethral cleaning with water is safer and cost-efficient than using antiseptics. and it can make reduce a patient's discomfort.

Sanitation Assessment and Microbiological Analysis of the Domestic Kitchen Utensils (가정 내 주방용품 및 기구의 위생실태 및 미생물학적 분석)

  • Kang, Myong-Suk;Chang, Yun-Hee
    • Korean journal of food and cookery science
    • /
    • v.24 no.5
    • /
    • pp.706-712
    • /
    • 2008
  • This study was conducted to evaluate the sanitation level and use of dish cloths, chopping board, and drawer in the refrigerator in 50 university students' houses located in Seoul and Kyonggido. The survey questionnaire evaluated general information, frequency of the washing, cleaning method, drying method and the associated factors. The highest percentage of the cleaning and drying methods of dish cloths were “boiling(76.0%)”, and “dry in the kitchen or on the sink(78.0%)”, respectively. For the chopping board and drawer in the refrigerator, the highest percentage of cleaning method was “use detergent” and drying method was “dry in the kitchen”. The mean of coliforms for dish cloths, chopping board, and drawer in the refrigerator was 4.46${\pm}$1.95 log CFU/100 $cm^2$, 3.92${\pm}$1.64 log CFU/100 $cm^2$, 3.48${\pm}$2.01 log CFU/ 100 $cm^2$, respectively. Salmonella spp. were not detected from all samples. But E. coli were detected from dish cloths(4.0%) and S. aureus were detected from dish cloths(16.0%), chopping board(12.0%), and drawer in the refrigerator(8.0%). The results of microbiological test of kitchen utensils indicated that the sanitary conditions of dish cloths, chopping board, drawer in the refrigerator should be improve promptly.

Experimental Study for Removing Artificial Patinas of Bronze Sculpture by Nd:YAG Laser Cleaning System (청동 조형물의 인공 파티나 제거를 위한 Nd:YAG 레이저 적용 실험 연구)

  • Park, Chang-Su;Cho, Nam-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.5
    • /
    • pp.197-207
    • /
    • 2013
  • In the midst of increasing importance of modern cultural assets, especially, most modern bronze objects are exposed to outdoor environment, and as the objects are corroded steadily due to environmental factors the objects lost their original colors on the surface. We performed artificial patinas on the bronze sample per each color of red, black and green and checked cuprite and tenorite which are detected from actual bronze corrosion by analyzing the components. In addition, we applied the existing corrosion removal methods of grinder and sand blaster on a similar sample of bronze mirror per injection pressure and performed comparative analysis on the result with Nd:YAG laser. As a result of Nd:YAG laser cleaning artificial patina from bronze samples, all of the patinas were removed by laser wavelength 1064 nm better than 532 nm. Upon applying to a similar sample of bronze mirror, the artificial patina could be selectively removed from substrates without surface damage when Nd:YAG laser was conducted other than the existing removal method, and so it showed the possibility of application.