• Title/Summary/Keyword: cleaning etc

Search Result 150, Processing Time 0.025 seconds

Relationship between Pollutant and Influence Factors in Highway runoff (강우시 고속도로 노면 유출 오염부하 발생 특성 분석)

  • Kang, Hee-Man;Lee, Doo-Jin;Bae, Woo-Keun;Kang, Hye-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.47-54
    • /
    • 2012
  • This study analyzed influence factors and the correlation among pollutants which affect occurrence of leaked pollution based on the long-term runoff flow and water quality investigation results to understand the characteristics of highway rainfall runoff pollution load. According to the result of correlation analysis on TSS (Total Suspended Solid) concentration, anteceded dry days, rainfall intensity, traffic volume and etc. as major influence factors of highway rainfall runoff pollution loads, the correlations were weak or scarce in most items. These results might be attributed that runoff pollutant concentration changes vary severely on changes of rainfall intensity and rainfall duration within rainfall and it is affected by disturbances of vehicles and street cleaning and etc. as characteristics of the highway. While Cu, Fe and Zn which are discharged with high concentrations out of heavy metals showed high correlation with particulate matter, organic matter(COD), nutrient(TN, TP), Ni and Pb showed relatively low correlation in a correlation evaluation by pollutant. Significant correlation with traffic volumes was not shown and TSS concentration even decreased in accordance with increase of the traffic volume. In the comparison with precedent studies, it was considered necessary additional analysis of the effects of rainfall section analysis, road type, disturbances of surface contaminants by vehicles, rainfall and climate conditions, surrounding terrains etc.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

A Study on the Low-energy Large-aperture Electron Beam Generator (저에너지 대면적 전자빔 발생장치 개발에 관한 연구)

  • Jo, Ju-Hyeon;Choe, Yeong-Uk;Lee, Hong-Sik;Im, Geun-Hui;U, Seong-Hun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.785-790
    • /
    • 1999
  • This research has been carried out to develop a low-energy large-aperture pulsed electron beam generator (LELA), 200keV 1A, for industrial applications. One of the most important feature of this electron beam generator is large electron beam cross section of $190cm^2$. Low energy electron beam generators have been used for water cleaning, flue gas cleaning, and pasteurization, etc. In these applications the cross sectionof the e-beam is related to reaction efficiency. Another important feature of this LELA EB generator is easy maintenance because of its simple structure and relatively low vacuum operation compared to the conventional EB generators. The conventional EB generators need to be scanned because the small cross section thermal electron emitters are used in the conventional EB generators which have small EB cross section. In this research, we use the secondary electrons generated by ion bombardment on the HV cathode surface as a electron source. Therefore we can make any shape of EB cross section without scanning.

  • PDF

Characteristics of Electron Beam Extraction in Cold Cathode Type Large Cross-Sectional Pulsed Electron Beam Generator (냉음극형 대면적 펄스 전자빔 가속기의 빔인출 특성)

  • Woo, S.H.;Lee, K.S.;Lee, D.I.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1609-1611
    • /
    • 2001
  • A large cross-section pulsed electron beam generator of cold cathode type has been developed for industrial applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The conventional electron beam generators need an electron scanning beam because the small cross section thermal electron emitter is used. The electron beam of large cross-section pulsed electron beam generator do not need to be scanned over target material because the beam cross section is large by 300$cm^2$. We have fabricated the large cross-sectional pulsed electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large area electron beam in the air. The electron beam current has been investigated as a function of accelerating voltage, glow discharge current, helium pressure, distance from the exit window and radial distribution in front of the exit window.

  • PDF

Test on the Mechanical Characteristics of Glass Fiber Membrane (유리섬유 막재의 역학적 특성에 관한 시험)

  • Park, Kang-Geun;Yoon, Sung-Kee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.55-62
    • /
    • 2008
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of membrane materials have fire proofing, lack of strength, self cleaning capacity, tear resistance, durability, heat insulation, sound insulation and elasticity. For the solution of this problems, it will be tested the mechanical properties of membrane material about tensile strength, tearing resistance, etc.

  • PDF

Characteristics of spatial distribution of cold cathode type large aperture electron beam (냉음극형 대면적 전자빔의 공간적 분포 특성)

  • Woo, S.H.;Abroyan, M.;Cho, C.H.;Kim, G.H.;Lee, H.S.;Rim, G.H.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2170-2172
    • /
    • 1999
  • A low energy large aperture(LELA) pulsed electron beam generator of a cold cathode type has been developed for environmental applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. We have fabricated the LELA electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large aperture electron beam in air. The electron beam current density has been investigated as a function of glow discharge current, accelerating voltage and radial distribution in front of the exit window foil. The plasma density and electron temperature have been measured in order to confirm the relation with the electron beam current density. We are going to upgrade the LELA electron beam generator in the electron energy, electron beam current and stability of operation for various applications.

  • PDF

Dryness of Mouth: A More Valuable Predisposing Factor of Self-perceived Bad Breath than Mechanical Cleansing in Dental Students

  • Ok, Soo-Min;Kim, Kyung-Hee;Heo, Jun-Young;Ahn, Yong-Woo;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.2
    • /
    • pp.41-46
    • /
    • 2015
  • Purpose: This study was performed to investigate a correlation among oral hygiene habits, dryness of mouth, and self-perceived oral malodor and therefore to find out self-care methods which could be a help to reduce oral malodor. Methods: A survey of 296 dental undergraduate students of School of Dentistry, Pusan National University, who wrote consents voluntarily and participated in this study, was conducted using a questionnaire consisting of 17 questions and analyzed to investigate a correlation among oral hygiene habits (frequency of tooth brushing, water gargling, and drinking water, etc.), dryness of mouth indicating the amount of salivary secretion, and self-perceived oral malodor. Results: There was no significant correlation between mechanical cleaning factors and self-perceived oral malodor. The factor showing a strong correlation with severe self-perceived oral malodor was dryness of mouth (p=0.000). Conclusions: There was no correlation between mechanical cleaning habits and self-perceived oral malodor. Participants who felt self-perceived oral malodor more tended to have rather good mechanical cleaning habits. The factor showing a strong correlation with severe self-perceived oral malodor was dryness of mouth. Therefore trying to increase salivary secretion is considered to be a help to reduce self-perceived halitosis.

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

Oxidation Added Wet Cleaning Process for Synthetic Diamonds (합성 다이아몬드를 위한 산화제가 첨가된 세정공정)

  • Song, Jeongho;Lee, Jiheon;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3597-3601
    • /
    • 2013
  • In this study, a wet cleaning process, P II, using aqua-regia and sulfuric acid mixture with oxidant agent ($K_2S_2O_8$, $P_2O_5$, $KMnO_4$, $H_2O_2$ etc) is proposed to remove the metastable phase of graphite such as graphene and DLC for high quality synthetic diamonds. The process employed the conventional acid cleaning process (P I) as well as P I+P II to remove the graphite related impurities from the 200um-diamond powders synthesized at 7GPa-$1500^{\circ}C$-5minutes. The degree of cleaning after P I and P I+P II has been observed by naked-eye, optical microscopy, micro-Raman spectroscopy, and TGA-DTA. After P I+P II, the color of diamond became more vividly yellow with enhanced saturation with naked eye and optical microscopy analysis. Moreover, the disappearance of diamond-like-carbon (DLC) peak ($1440cm^{-1}$) observed by Raman spectroscopy confirmed the decrease in amount of remaining impurities. TGA-DTA results showed that the graphite impurities first started to dissolve at $770.91^{\circ}C$ after PI process. However, the pyrolysis started at $892.18^{\circ}C$ after P I+P II process because of the dissolution of pure diamonds. This result proved the effective dissolution of the metastable phase of graphite. We expect that the proposed P II process may enhance the quality of diamonds through effective removal of surface impurities.

Machining Characteristics according to Electrochemical Polishing (ECP) Conditions of Stainless Steel Mesh (스테인리스 망의 전기화학 폴리싱(ECP) 조건에 따른 가공 특성)

  • Kim, Uk Su;Park, Jeong Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.41-48
    • /
    • 2015
  • Stainless steel mesh has been used as a filter in various fields, including domestic, medical, etc. However, the surface before machining may have an adverse effect the product quality and performance because it is not smooth. Especially, adsorbed impurities in the surface result in difficulty in cleaning. Therefore, in this paper, we propose an improved surface quality through electrochemical polishing (ECP). Two electrodes, composed of STS304 (anode) and copper (cathode) underwent machining with two conditions according to polishing time and current density. As the polishing time and current density increase, the surface of curvature decreases, and roughness and material removal rate (MRR) improves. The machined surface roughness and image were obtained through the atomic force microscope (AFM) and stereoscopic microscope. The study also analyzed hydrophilic effect through contact angles. This obtains corrosion resistance, smoothness, hydrophilic property, etc.