• Title/Summary/Keyword: clean environment

Search Result 974, Processing Time 0.029 seconds

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

Investigation of Applying Technical Measures for Improving Energy Efficiency Design Index (EEDI) for KCS and KVLCC2

  • Jun-Yup Park;Jong-Yeon Jung;Yu-Taek Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.58-67
    • /
    • 2023
  • While extensive research is being conducted to reduce greenhouse gases in industrial fields, the International Maritime Organization (IMO) has implemented regulations to actively reduce CO2 emissions from ships, such as energy efficiency design index (EEDI), energy efficiency existing ship index (EEXI), energy efficiency operational indicator (EEOI), and carbon intensity indicator (CII). These regulations play an important role for the design and operation of ships. However, the calculation of the index and indicator might be complex depending on the types and size of the ship. Here, to calculate the EEDI of two target vessels, first, the ships were set as Deadweight (DWT) 50K container and 300K very large crude-oil carrier (VLCC) considering the type and size of those ships along with the engine types and power. Equations and parameters from the marine pollution treaty (MARPOL) Annex VI, IMO marine environment protection committee (MEPC) resolution were used to estimate the EEDI and their changes. Technical measures were subsequently applied to satisfy the IMO regulations, such as reducing speed, energy saving devices (ESD), and onboard CO2 capture system. Process simulation model using Aspen Plus v10 was developed for the onboard CO2 capture system. The obtained results suggested that the fuel change from Marine diesel oil (MDO) to liquefied natural gas (LNG) was the most effective way to reduce EEDI, considering the limited supply of the alternative clean fuels. Decreasing ship speed was the next effective option to meet the regulation until Phase 4. In case of container, the attained EEDI while converting fuel from Diesel oil (DO) to LNG was reduced by 27.35%. With speed reduction, the EEDI was improved by 21.76% of the EEDI based on DO. Pertaining to VLCC, 27.31% and 22.10% improvements were observed, which were comparable to those for the container. However, for both vessels, additional measure is required to meet Phase 5, demanding the reduction of 70%. Therefore, onboard CO2 capture system was designed for both KCS (Korea Research Institute of Ships & Ocean Engineering (KRISO) container ship) and KVLCC2 (KRISO VLCC) to meet the Phase 5 standard in the process simulation. The absorber column was designed with a diameter of 1.2-3.5 m and height of 11.3 m. The stripper column was 0.6-1.5 m in diameter and 8.8-9.6 m in height. The obtained results suggested that a combination of ESD, speed reduction, and fuel change was effective for reducing the EEDI; and onboard CO2 capture system may be required for Phase 5.

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.

A Study for Promotion of the Stay Type Tourism in Ulsan by IPA Analysis Techniques (IPA분석을 통한 울산의 체류형 관광 활성화 방안 연구)

  • You, Young-Jun;Lee, Ji-Hun;Chung, Yoon-Jo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.8
    • /
    • pp.1-12
    • /
    • 2019
  • The purpose of this study is to explore ways to promote the stay type tourism in Ulsan. To achieve this, IPA analysis techniques were applied to survey the importance and performance of experts, tourists, and hotel users, and measures were developed for activation of common points among the groups. Most studies analyze the survey results of a group, but this study compared and analyzed the results among three groups of experts, tourists, and hotel users, resulting in areas requiring activation. According to the results of each group, 'cultural facilities' were selected as the attraction factor, and 'night tours' were chosen as the basic factor to improve. On the other hand, tourist attractions, clean environment and urban parks have been selected as implementation factors, which correspond to the "ecological tourism," one of Ulsan's five-color themes. According to the ranking, the three groups of experts, tourists, and hotel users were able to look at the results of priority items that were selected up to the third place, although there were no exact matching factors. The items selected by both groups were diversification of night viewing, traffic accessibility in tourist sites, and improvement of night scenery, operation of night experience programs, extension of night opening hours, and revitalization of night markets respectively.

Review of Problems with Use of Halogenated Cleaning Solvents Revealed through Case Studies of Cleaning Solvent Poisoning and Analysis of Domestic and Overseas Regulations (세척제 용매 중독 사례와 국내·외 규제 검토를 통한 할로겐화 용매 세척제 사용의 문제점 고찰)

  • Naroo Lee;Hye Jin Lee;Sujin Jeong;Dohee Lee;Arom Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.517-527
    • /
    • 2023
  • Objectives: We examine cases of chemical poisoning that occurred in the cleaning of metal parts and the regulations on halogenated solvents in other countries and propose regulations necessary to prevent chemical poisoning from halogenated solvents. Methods: We collected cases of chemical poisoning through the website of the Korea Occupational Safety and Health Agency. A review of the literature was conducted focusing on regulations related to halogenated solvents in the United States and the European Union, particularly for cleaning metal parts. Among the Material Safety Data Sheets submitted to the government, MSDS containing eleven substances were extracted to confirm the composition and product use. We investigated cleaning methods for metal parts used in South Korea. For the hazard classification, the European Chemicals Agency or Japan's NITE's website was used. Results: In the case of poisoning, the cleaning methods involving trichloromethane were dipping and dry, which was not found in the literature. It was confirmed that many halogenated solvents and dimethyl carbonate were used for metal cleaning in South Korea. In vapor degreasing using TCE in the USA, even if the facility is strictly managed, such as by installing cooling coils in open cleaning facilities, the risk of exposure to TCE is considered to be not only carcinogenic but also a concern for acute and chronic effects. In comparison, exposure through Korean work methods such as dipping and drying operations is inevitably much higher. Conclusions: The transition to water-based cleaning with low-hazard chemicals should be a priority in the cleaning process. In the case of metal parts that require precise cleaning, if the use of a halogenated solvent is inevitable, a closed degreasing facility should be used to minimize exposure. The current regulations in the Occupational Safety and Health Act, the Chemical Substances Control Act, and the Air Environment Conservation Act do not require cleaning facilities to minimize emissions. To protect the health of workers using halogenated solvents to clean metal parts, regulations that require a fundamental reduction in exposure will be necessary.

Foundation Color Image Analysis (파운데이션 색상 이미지 분석)

  • Hee-Kyung Lim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.1580-1588
    • /
    • 2023
  • The desire for clear and clean skin is universal among both men and women. Women, in particular, seek the help of foundation to achieve beautiful and transparent skin. The choice of foundation is not determined by the race of an individual; instead, it varies based on personal skin color and undertone. Therefore, there is a need to surpass the stereotype of using foundation colors based on racial discrimination. The purpose of this study is to randomly select cosmetics brands from Korea, China, Japan, the United States, France, and the United Kingdom, considering the impact of each photo, environment, and equipment. The objective is to understand the differences in skin tones in foundation advertisement model images on websites. Analyzing the RGB values of foundation colors for each brand revealed that in Korea, the colors were 8.75R, 1.25YR, 2.5YR, 3.75YR, 5YR, and 6.25YR. Chinese brands showed similar colors with 2.5YR, 3.75YR, 5YR, 6.25YR, and 10YR. Japanese brands displayed colors such as 7.5R, 8.75R, 10R, 5YR, 6.25YR, and 7.5YR. American brands presented colors like 6.25R, 8.75R, 10R, 2.5YR, 3.75YR, 5YR, 6.25YR, 7.5YR, and 10YR. French brands featured 10R, 1.25YR, 3.75YR, 5YR. Lastly, British brands displayed 2.5YR, 3.75YR, 7.5YR. As a follow-up study, in-depth research on the reshaping and color changes of foundation over time is recommended. It is hoped that this research will serve as fundamental data for makeup companies' marketing and contribute to the development of both domestic and international color cosmetics markets.

Current Distribution of Cottus pollux (Pisces: Cottidae) in Korea (한국산 민무늬둑중개 Cottus pollux (Pisces: Cottidae)의 분포 현황)

  • Bong Han Yun;Yong Hwi Kim;Ho Sung Lee;Eun Seon Seo;Sue Hyeung Lee;In-Chul Bang
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.2
    • /
    • pp.92-101
    • /
    • 2024
  • Current distribution of Korean Cottus pollux was investigated by conducting field surveys and environmental DNA analysis in September to November 2022 and March to May 2023. As a result of the field survey, the presence of C. pollux was confirmed in the uppermost stream of Hyeongsangang River, as well as in Deokdongcheon, Jeolgolcheon, and Hoamcheon Streams. The main habitat of C. pollux was the riffle area in the upper reaches of streams with clean water and boulder-cobble bottoms. As a result of environmental DNA analysis, the samples determined to be positive included all streams in which the presence of C. pollux was confirmed in the field survey. In addition, Namcheon and Singwangcheon Streams were determined to be positive, indicating potential as its habitats. Since C. pollux has a narrow distribution area and a small population size, continuous monitoring and conservation measures are required to immediately respond to damage caused by typhoons and river works, which are the main causes of habitat disturbance, in order to maintain a stable population.

Importance and Performance of High School Foodservice Hygiene in Busan (부산지역 일부 고등학생의 급식 위생 중요도 수행도 평가)

  • Park, Jung-Sun;Lyu, Eun-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1757-1765
    • /
    • 2014
  • The objective of this study was to explore hygiene issues by analyzing the importance and performance of personal and school hygiene in school foodservices. Questionnaires were administered to 634 students (10 high schools) in the Busan area. Exactly 29% of respondents had received hygiene education. The average score of importance of students' personal foodservice hygiene was 3.81/5.00, and the performance score was 3.48/5.00. The same scores for school foodservice hygiene were 4.37/5.00 and 3.67/5.00, respectively. Regarding importance and performance of personal foodservice hygiene, students who had received hygiene education showed significantly (P<0.01) higher scores than those without prior education. In terms of importance of school foodservice hygiene, students who had received hygiene education showed significantly higher scores for environment hygiene (P<0.05) and equipment hygiene (P<0.05). Additionally, among grid analysis in personal foodservice hygiene, the areas of high importance and low performance included 'washing hands before the meal', 'using a designated cup for the water purifier', and 'keeping clean around the leftover container'. As for school foodservice hygiene, the same area was 'cleanliness of tray'. These findings suggest that hygiene education needs to be extended to more students, and for school foodservice hygiene, a cleaner environment should be created using equipment hygiene management, including emphasis on ensuring cleanliness of tray.

Pyrolysis Characteristics of CCL(Copper Clad Laminate) Based Paper/Phenolic Resin Composites (종이/페놀수지가 주성분인 동박적층판(Copper Clad Laminate)의 열분해 특성)

  • Song, Jae-Hun;Kim, Seung-Do;Ahn, Hyun-Cheol;Kim, Gyung-Soo;Kim, Sang-Bum;Jung, Jae-Sung;Gong, Sung-Ho;Cho, Young-Gae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1013-1019
    • /
    • 2007
  • Electronic wastes have increased tremendously. However, any reliable treatment methodologies have rarely been established. Electronic wastes have posed serious disposal problem due to their physico-chemical stability. This paper investigated the application possibility of pyrolysis for the purpose of recycling the p-CCL(phenol based Copper Clad Laminate). Thermogravimetric analysis(TGA) was used to investigate the thermal decomposition pattern of p-CCL. We elucidated the characteristics of pyrolysis by-products at operating temperatures of 280, 350 and $600^{\circ}C$. GC/MS and FT-IR were used to characterize the liquid by-products along with general characterization methods such as Ultimate Analysis, Proximate Analysis and Heating Value, whereas general characterization methods were only introduced for the solid by-products. At a heating rate of $5^{\circ}C$/min, TGA curves exhibited three decomposition stages: (1) low-temperature decomposition region$(<280^{\circ}C)$, (2) medium temperature region$(280\sim350^{\circ}C)$ and (3) high-temperature region$(>350^{\circ}C)$. The major compounds of liquid by-products at low- and medium-temperatures were accounted for by water and phenol, whereas branched phenols and furans were major compounds at high-temperatures. As the temperature increases, volatile quantities decreased but the fixed carbon increased. High heating values of solid by-products($7,400\sim7,600$ kcal/kg) would suggest that the solid by-products could be applicable as fuel. In addition, high fixed carbon but low ash content of the solid by-products offered an implication that they are capable of being upgradable for adsorbent after applying appropriate activating process.

Field Survey on the Maintenance Status of Greenhouses in Korea (온실의 유지관리 실태조사 분석)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Hyeon Tae;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • The purpose of this study was to investigate greenhouse maintenance by farms by looking into greenhouses across the nation for greenhouse specification, disaster-resistance greenhouse construction, types and degree of damage due to natural disasters, pre-inspection in case of typhoon or heavy snow forecast, and fire-fighting facilities to prevent a fire. The findings were summarized as follows: as for greenhouse specification, the highest proportion of them were 90 m or longer both in single- and multi-span greenhouses in terms of length; 8 m or wider and 7.0~7.9 m in single- and multi-span greenhouses, respectively, in terms of width; 1.5~1.9 m and 2.0~2.9 m in single-and multi-span greenhouses, respectively, in terms of height; and 3.0~3.9 m and 6 m in single- and multi-span greenhouses, respectively, in terms of diameter. As for disaster-resistance greenhouses, farmers were reluctant to install such greenhouses. The low distribution of disaster-resistance greenhouses was attributed to the greenhouses built dependent on the old practice, the greenhouses already completed, and relatively high construction costs. As for damage by natural disasters, greenhouses were subject to more damage by typhoons than heavy snow. They mainly inspected the ceiling and side windows, entrances, and fixation bands for covering materials in case of typhoon forecast and the heating devices in case of heavy snow forecast. As for repair methods for greenhouse pipe corrosion, they preferred partial replacement to painting and did not use stiffeners for structures to prevent a natural disaster in most cases. As for the maintenance of greenhouse covering materials, most farmers inspected their sealing property but did not clean the coverings for light transmission. The destruction of structural materials can be prevented by eliminating greenhouse covering materials during a typhoon, but they were not able to do so because of the covering material replacement costs and the crops they were growing. The study also examined whether greenhouse farms had fire-fighting facilities to prevent a fire and found that they lacked the perception of greenhouse fire prevention to a great degree.