• 제목/요약/키워드: clayey layer

검색결과 48건 처리시간 0.024초

연천 은대리 물거미 서식지의 수문적 특성 (Hydrological Properties of the Water Spider Habitat in Yeoncheon)

  • 양재혁
    • 한국지형학회지
    • /
    • 제26권1호
    • /
    • pp.107-119
    • /
    • 2019
  • In recent years, the drying of the water spider habitat has been progressing rapidly. This is the primary cause of extreme climatic events in 2014/2015 with overall reduction in annual precipitation, but impermeable clayey layer formed in the superficial formation also plays an important role. The clayey layer is a critical factor in the formation of wetlands on a well-drained lava plateau, but paradoxically, it restricts the connection with ground water, increasing the instability of the water balance and making it precipitation-dependent structure. In addition, construction of roads/drainways has also caused drying of wetlands by blocking or rapidly spilling surface water/sheet flow. Therefore, to keep the wetlands sustainable, it should increase the flow into the wetlands by removing the road/drainways and floodgates installed to reduce the outflow.

세립분 함유율에 따른 점토질 모래의 역학적 특성 및 적용성 평가 (Evaluation of Mechanical Characteristics and Applicability of Clayey Sand by Fines Content)

  • 김정면;안준영;허재영;이승주;김영석;문범수;김용성
    • 한국지반신소재학회논문집
    • /
    • 제22권3호
    • /
    • pp.47-59
    • /
    • 2023
  • 본 연구에서는 점토질 모래(SC)를 대상으로 실내시험을 수행하여 물리적 특성, 압밀/투수 특성, 응력-변형 특성을 분석하고, 세립분 함유량에 따라 모래에서 점토로 흙의 역학적 성질이 변화되는 전환 세립분 함유율을 도출하였다. 또한 현장 적용성 평가를 위해 실제 과다침하로 인하여 문제가 발생된 연약지반 개량 현장의 계측자료를 수집하여 실내시험 및 수치해석 결과를 바탕으로 도출된 침하특성과 현장에서 계측된 실제 침하특성을 비교·분석하여 SC의 압밀 대상층 적용성 평가를 수행하였다. 실내시험 및 압밀해석 결과 SC는 세립분 함유율 25%이상에서 사질토에서 점성토로의 역학적 특성 변화가 나타났으며, 점성 토로의 역학적 특성 전환은 점토입자의 함유율과 매우 밀접한 관계가 있는 것으로 나타났다. 연약지반 현장의 수치해석을 통해 전환 세립분 함유율 이상의 점토질 모래를 압밀 대상층으로 적용한 경우, 침하량이 계측침하량 대비 평균 91.2%로 거의 일치하는 결과를 확인하였다. 따라서 연약지반 설계에서 압밀대상층 범위 선정 시 전환 세립분 함유율 이상의 점토질 모래는 연약지반에 포함하여 적용하는 것이 바람직할 것으로 판단된다.

해성퇴적층 지반의 가시설토류벽 수평변위 특성에 관한 연구 (Characteristics for Horizontal Displacement of Temporary Earth Retaining Wall on Marine Sediments)

  • 김영훈;김찬기;최성열;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제11권11호
    • /
    • pp.37-45
    • /
    • 2010
  • 본 연구에서는 서해안 ${\bigcirc}{\bigcirc}$지역에서 IPS 지지방식과 Strut 지지방식으로 시공한 현장의 계측에 의한 수평변위량을 수치해석상의 예측치와 비교하고, 실무에서 널리 사용되고 있는 탄소성보법 해석 프로그램(SUNEX, EXCAV)을 이용하여 해석치를 상호 비교분석 하였다. 또 최대수평변위에 대한 여러 제안값 중 점토지반에 적용한 제안값과 비교한 결과, IPS 지지 방식과 Strut지지방식에 의한 최대 수평변위는 IPS지보형식이 Strut지보형식보다 더 크게 발생하였으며, SUNEX 프로그램 해석치와 EXCAV 프로그램 해석치를 상대 비교했을 때 SUNEX 프로그램이 더 크게 해석되었지만, 점토층에서의 기존 제안값인 0.5%H 에는 더 근접하다는 결론을 얻었다. 이는 SUNEX 프로그램이 해석 시 지보형식이나 사용하는 부재 보다는 토질 정수 중 내부마찰각(${\Phi}$)에 의해 수평변위값이 영향을 받기 때문이라 판단된다. 즉 내부 마찰각이 큰 사질토 지반에서는 수평변위값이 작게 발생하고, 내부 마찰각이 작은 점성토 지반에서는 수평변위가 크게 해석되어 상호 비교 시 사질토 지반에서는 EXCAV가 크게 나타나고 점성토 지반에서 SUNEX가 크게 나타났다고 판단된다. 또한, 기존 제안 값 중 점성토에 적용한 0.5%H와 비교 시 현장계측치는 평균 141%, SUNEX로 예측한 결과치는 평균 78.1%, EXCAV로 예측한 결과치는 평균 18.1% 범주에 분포함을 확인하였다. 따라서, 흙막이 가시설 설계 시사용하고 있는 해석 프로그램으로 산정한 수평변위량이 실제 현장에서 계측한 변위량을 과소 예측하므로 지반거동을 모사하는데 주의를 요한다. 추후 보다 정밀한 유한요소해석 등을 통하여 실제 거동의 예측 가능성을 평가해야 할 것이다.

부산점토의 특성: 가덕도 지역 조간대 퇴적물의 대자율 (The Properties of Pusan Clay : Magnetic Susceptibility of Deltaic sediments in Gadeok-do Area)

  • 김성욱;김인수;이선갑;김무겸;정성교
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.747-752
    • /
    • 2003
  • This study was carried out to understand the stratigraphy and depositional environment of clayey soils that distributed in the Gadeok-do area, Kimhae plain (Nakdong estuary). For the study, SPT core sampling and magnetic susceptibility analysis were conducted. Soils in study area is classified into five sedimentary facies ascending order; sand/gravel. clay, sand/gravel, clay, interbedded sand and silty clay. Analysis of magnetic susceptibility for Gadeok-do clayey soil reveals that depositional process and environment can be divided into upper, middle and lower layer, and they are closely related to the sea level change since late Quaternary.

  • PDF

Ultimate Bearing Capacity of Strip Foundation on Geogrid -Reinforced Clayey Soil

  • Shin, Eun-Chul;Choi, Chan-Yong
    • 한국지반공학회지:지반
    • /
    • 제13권3호
    • /
    • pp.77-86
    • /
    • 1997
  • 여러층의 지오그리드로 보강된 포화된 점토질지반에 띠기초의 극한 지지력에 대한 실내모형 실험결과를 제시하였다. 최대 극한지지력을 유발하는데 필요한 최적 보강길이와 보강심도, 첫번 째층의 지오그리드 보강심도를 도출하였다. 모형실험결과를 바탕으로 극한 지지력을 도출할 수 있는 준경험 방정식을 제시하였다.

  • PDF

탄점성압밀방정식을 이용한 점성토의 일차원 압밀 해석에 관한 연구 (One-dimensional consolidation analysis of clayey soils based on elasto-viscous liquid model)

  • 염혜선;김지용;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.689-694
    • /
    • 2000
  • The traditional concept after Terzaghi was that consolidation was the dissipation process of pore water pressure compatible to external loading which was generated immediately after the loading. However, a theory of one-dimensional consolidation based on elasto-viscous liquid model proposed by Yoshikuni(1994) explained that the process of primary and secondary consolidation was considered to be not a simple process of dissipation of pore water pressure but a simultaneous process of dissipation and generation by external loading. This study attempts to demonstrate general consolidation behaviour of clayey soils including effects of consolidation history, load increment and thickness of cohesive layer by one-dimensional Finite Difference Method(F.D.M) analysis from the viewpoint of elasto-viscous consolidation theory.

  • PDF

부산 명지주거단지 연약 점토의 지반 공학적 특성 (Geotechnical Characteristics of Soft Clay in Myungji Housing Complex)

  • 이석진;양희정;이준호;김정관;성상규;이주호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.445-454
    • /
    • 2006
  • Myungji Housing Complex is located in the Nakdong River plain in which the Busan soft clays are developed. It has thick soft soil laver of about GL(-)50m including loose sandy layers, upper and lower clayey layers. The clayey layers have been being consolidated since the land reclamation was completed to build the place for Housing Complex(Apartment) in 1997. Therefore, as one of a series of advance preparations of this project, study was carried on the geotechnical characteristics under the foundation The first part of this paper represents a brief geological history. Then, geotechnical characteristics of clay was analyzed in the classical developments in soft clay. They were based on the geotechnical data obtained by site investigations performed from 1992 to 2005. Finally, we evaluated the average degree of consolidation at this point in time and the residual settlements of upper clayey layer using dissipation and oedometer tests for this project

  • PDF

수치해석을 이용한 점성토 지반의 아이소크론 영향 분석 (Analysis of Isochrone Effect of Clayey Soils using Numerical Analysis)

  • 이윤식;이종호;이강일
    • 한국재난정보학회 논문집
    • /
    • 제15권1호
    • /
    • pp.84-97
    • /
    • 2019
  • 연구목적 : 연약지반의 압밀침하는 연약 점토층 상하부에 분포하는 지층의 투수성(경계조건), 점토층의 두께, 그리고 하중 재하 폭에 따라 간극수압 분포특성이 달라짐에도 불구하고, 현재 설계의 대부분은 점토층의 깊이에 따른 초기간극비가 일정하다는 가정 하에 제안된 Terzaghi 1차원 압밀이론에 의한 아이소크론(Isochrone)을 이용하여 압밀시간을 산정하고 있다. 연구방법 : 따라서 본 연구에서는 하중 재하 폭, 점토층의 두께, 그리고 점토층 하부의 배수조건이 변화할 때 발생하는 과잉간극수압 소산형태를 수치해석적 방법으로 점토의 깊이별로 시간에 따른 과잉간극수압 변화를 체크하고, 이를 Terzaghi 1차원 압밀이론에 의한 아이소크론과 비교 분석하여 합리적인 압밀시간 결정방법을 제시하고자 한다. 연구결과 : 본 연구 결과, Terzaghi가 제안한 압밀도-시간계수 곡선에 가장 이상적인 경우가 아닌 경우에는 Terzaghi 1차원 압밀이론에 의한 압밀도-시간계수 곡선, 압밀시간 산정에 유의해야 하며, 가능한 수치해석에 의한 압밀도-시간계수 곡선을 사용하여 압밀시간을 산정하여야 한다.

Deep neural network based seafloor sediment mapping using bathymetric features of MBES multifrequency

  • Khomsin;Mukhtasor;Suntoyo;Danar Guruh Pratomo
    • Ocean Systems Engineering
    • /
    • 제14권2호
    • /
    • pp.101-114
    • /
    • 2024
  • Seafloor sediment mapping is an essential research topic in shallow coastal waters, especially in port development, benthic habitat mapping, and underwater communications. The seafloor sediments can be interpreted by collecting sediment samples directly in the field using a grab sampler or corer. Another method is optical, especially using underwater cameras and videos. Both methods each have weaknesses in terms of area coverage (mechanic) and accurate positioning (optic). The latest technology used to overcome it is the acoustic method (echosounder) with Global Navigation Satellite System (GNSS) Real Time Kinematic (RTK) positioning. Therefore, in this study will propose the classification of seafloor sediments in coastal waters using acoustic method that is Multibeam Echosounder (MBES) multi-frequency with five frequency (200 kHz, 250 kHz, 300 kHz, 350 kHz, and 400 kHz). In this study, the deep neural network (DNN) used the bathymetric multi frequency, bathymetric difference inters frequencies, and bathymetric features from 5 (five) frequencies as input layer and 4 (four) sediment types in 74 (seventy-four) sample sediment as output layer to make a seafloor sediment map. Results of sediment mapping using the DNN method show an overall accuracy of 71.6% (significant) and a kappa coefficient of 0.59 (moderate). The distribution of seafloor sediment in the study area is mainly silt (41.6%), followed by clayey sand (36.6%), sandy silt (14.2%), and silty sand (7.5%).

연약지반상 고속철도 노반 축조시 지오셀 시스템의 효과 (Reinforcement of Soft Soil Subgrade for High-Speed Railroad Using Geocell)

  • 김진만;조삼덕;윤수호;정문경;김영윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.129-141
    • /
    • 1999
  • This paper presents the results of plate load test and dynamic load test performed to evaluate the performance of geocell where it is used to reinforce soft subgrade for high-speed railroad. Efficacy of geocell was observed in increase in bearing capacity of subgrade and reduction of thickness of reinforced sub-ballast. Plate load tests were carried out at four different places with varying foundation soil strength as a function of number of geocell layer, type of filler material, thickness of cover soil, and the presence of non-woven geotextile. Dynamic load tests were performed in a laboratory. The test soil chamber consists of, from the bottom, 50 cm thick clayey soil, one layer of geocell filled with crushed stone, 10 cm thick crushed stone cover, reinforced sub-ballast of varying thickness, 35 cm thick ballast. This configuration was determined based on the results of numerical analysis and plate load tests. For each set of the dynamic load tests, loads were applied more than 80,000 times. One layer of geocell underlying a 10 cm thick cover soil led to an increase in bearing capacity three to four times compared to a crushed stone layer of the same thickness substituted for the geocell and cover soil layer. Given the test conditions, the thickness of reinforced sub-ballast can be reduced by approximately 35 cm with the presence of geocell.

  • PDF