• 제목/요약/키워드: claw

검색결과 123건 처리시간 0.026초

Claw Pole 영구자석형 스테핑 모터의 정특성 향상에 관한 연구 (A study on the improvement of static characteristic In claw poled permanent magnet stepping motor)

  • 정대성;임승빈;김태형;이주;권호;손영규;최승길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1288-1290
    • /
    • 2005
  • This paper analyzed the characteristics of the claw pole PM step motor by using 3D FEM. As the magnetization occurs along the z-axis of the motor, it is necessary to apply 3D FEM for analysis of the claw pole PM step motor. Considering the computation time, however, the number of the analysis model is minimized by using the "Design of Experiments(DOE)". By using the "DOE", efficient analysis was able to be done. To see the effects of the design factors, the 3D FEM is applied only to the selected models. As the design factors, the teeth shape, the number of turns and the permanent magnet overhang was selected.

  • PDF

Technical Advances in Pectus Bar Stabilization in Chest Wall Deformity Surgery: 10-Year Trends and an Appraisal with 1,500 Patients

  • Heekyung Kim;Gongmin Rim;Hyung Joo Park
    • Journal of Chest Surgery
    • /
    • 제56권4호
    • /
    • pp.229-237
    • /
    • 2023
  • Background: We aimed to demonstrate the advances we have achieved in pectus excavatum surgery over the last 10 years, with a particular focus on the refinement of pectus bar stabilization techniques and devices. Methods: In total, 1,526 patients who underwent minimally invasive repair of pectus excavatum surgery from 2013 to 2022 were enrolled and analyzed. We have pursued a new paradigm of crane-powered remodeling of the entire chest wall. The method of bar stabilization has changed from claw fixators to hinge plates and, finally, to bridge plate connections. We also evaluated the effectiveness of the hinge plate (group H) and the bridge plate (group B). Results: The bar displacement rates were 0.1% (n=2) for the claw fixator, 0% for the hinge plate (n=0), and 0% for the bridge plate (n=0). We stopped using the claw fixator in 2022 and the hinge plate in 2019. Since 2022, when we shifted to a multiple-bar technique for all patients, the bridge plate has replaced both the claw fixator and the hinge plate. No bar displacement occurred in either group. Group H had more pleural effusion, wound problems (p<0.05), and longer stays (5.5 vs. 6.2 days, p=0.034) than group B. Conclusion: We have made significant progress in pectus repair surgery over the last decade, particularly in stabilizing the pectus bar and reducing perioperative complications. Our current strategy is the multiple-bar approach with bridge stabilization. Since the bridge-only technique resulted in no bar displacement, we could eliminate the invasive claw fixator or hinge plate.

소 발굽병의 외과적 치료법 및 발굽마취법 확립에 관한 연구 (Study on application of surgical therapeutic method of foot diseases and foot anesthesia technique in cattle)

  • 정순욱;윤석정
    • 대한수의학회지
    • /
    • 제39권1호
    • /
    • pp.240-246
    • /
    • 1999
  • forty-five claw lamed cows with pododermatitis circumscripta, hyperplasia interdigitalis, and dermatitis verrucosa were treated surgically through resection of necrotic tissues, currettage, antibiotics application, and compressive bandage, under retrograde intravenous regional anesthesia of claw. At 7 days postoperation were showed lameness score 0, absense of swelling of extremitis, without fistulation and purulent exudate in wound. Mean duration time of action of local anesthetic drug was 75 minutes and mean operation time for treatment of pododermatitis circumscripta, hyperplasia interdigitalis, and dermatitis verrucosa was 35 minutes, 20 minutes, and 21 minutes, respectively.

  • PDF

등가 자기회로법을 이용한 Claw-pole type generator의 특성해석 (An Application of Equivalent Magnetic Circuit method to the analysis of Claw-pole type generator)

  • 정재우;권순오;이상호;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.120-122
    • /
    • 2005
  • Magnetic field analysis of claw-pole type generator using equivalent circuit is presented in this paper. On the basis of 3D geometry and flux paths, equivalent magnetic circuit is designed and field analysis is performed by solving the circuit. Non-linear characteristic of material is considered for precise analysis results. 3D FEA is performed to verify analysis results, and flux densities in rotor and stator regions are compared. Calculated no-load back emf for field input voltage and speed are verified by experiment. Comparing to 3D FEA, presented method provides precise results with instant calculation time.

  • PDF

Parameter Optimal Choice of Claw Pole Alternator based on Iron Loss Model

  • Bao, Xiaohua;Wei, Qiong;Wu, Feng;Li, Jiaqing
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.260-268
    • /
    • 2013
  • Based on classical Berotti discrete iron loss calculation model, the iron loss analysis mathematical model of alternator was proposed in this paper. Considering characteristics of high speed and changing frequency of the alternator, Maxwell 3-D model was built to analyze iron loss corresponding to each running speed in alternator. Based on iron loss model of alternator at rated speed, the rotor claw pole size was made an optimization design. The optimization results showed that alternator's output performance had been improved. A new idea was explored in size optimization design of claw pole alternator.

3차원 유한요소법을 이용한 영구자석형(PM) Claw pole 스텝 모터의 특성 해석 (Characteristic Analysis of Permanent Magnet Type Step Motor with claw poles by using 3 dimensional Finite Element Method)

  • 임승빈;김태형;정대성;이주;권호;손영규;김윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.749-751
    • /
    • 2004
  • This paper analyzed the characteristics of the claw pole PM step motor by using 3D FEM. In case of analysing this type of motor, 3 dimensional analysis is necessary for an accurate analysis due to the magnetizing component of the z-axis direction. As a main design variable, the magnetization, width and the effects of skewing was selected. The variation of the detent torque and the back EMF depending on the shape of the pole is also shown.

  • PDF

Claw-Pole을 갖는 PM형 스테핑 모터의 과도응답 특성 해석 (Transient Response Characteristics Analysis of Permanent Magnet Type Stepping Motor with Claw Poles)

  • 안지현;김경민;박승찬;류세현;정인성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1264-1266
    • /
    • 2005
  • This paper analyzes static and transient response characteristics of a permanent magnet type stepping motor with claw poles using three-dimensional finite element method. The outer diameter of the stepping motor to be analyzed is approximately 6 mm. In this paper we analyzes only 2 poles of the stepping motor, which has 10 magnetic poles made up of NdFeB material, using periodic boundary condition. We clarify transient response and static torque charateristics using Maxwell 3D and Matlab Simulink.

  • PDF

클로폴형 리니어 모터의 개발 (The Design of Claw Pole Type Linear Motor)

  • 이봉섭;김중기;김남훈
    • 한국산업융합학회 논문집
    • /
    • 제5권2호
    • /
    • pp.127-132
    • /
    • 2002
  • In this paper, the new claw pole type linear stepping motor(CPLSM) is proposed. And the magnetic equivalent circuit of CPLSM is derived by the structure of the CPLSM. The design parameter and the magnetic flux density of CPLSM are performed with three-dimensional finite element method.

  • PDF

소족지 변형의 치료 (Treatment of Lesser Toe Deformities)

  • 배서영
    • 대한족부족관절학회지
    • /
    • 제17권1호
    • /
    • pp.17-22
    • /
    • 2013
  • Lesser toe deformities such as mallet toe, hammer toe and claw toe are annoying problems not only to patients but also to orthopaedic surgeons because they are not easy to manage or treat. Though they occupy very small portion in whole body, they are notorious for unpredictable surgical results. It can make clinical results better to understand these deformities more comprehensively and to make strategic surgical plan for each target deformity.

발굽 천행우에서 회귀성 국부 정맥무취위 활용에 관한 연구 (Study on the Application of Retrograde Intravenous Regional Anesthesia in Claw Lamed Cows)

  • 정순욱
    • 한국임상수의학회지
    • /
    • 제15권1호
    • /
    • pp.56-61
    • /
    • 1998
  • A retrograde intravenous regional anesthesia was applied to the extremities of 30 cows, which was showed that mean value of induction time was 13.5 seconds, duration time 74.4 minutes, frequency of injection until to keep needle into the vein 1.27, and didn't observed local and systemic complications. Under the retrograde intravenous regional anesthesia, it was possible for surgical treatment of 20 cows with various foot disorders, to resect soft tissues of extremities and claw horns, to sexarticulate 2nd phalanx without pain reactions.

  • PDF