Analysis of Safety Decrees for Gas Safety Management System and its Development (주요선진국의 가스기술기준 체제분석 및 제도개선 발전 모형)

  • 김봉진;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.2
    • /
    • pp.51-63
    • /
    • 2001
  • Korea gas industrial because of received LNG in 1987 was converted by the Gas Safety Management System in relation to city gas, LPG and LNG. Gas accident were caused by treatment problem on the supplier and user, on technical and use management mater, on facilities and goods, and included problem with gas safety connection system. This study is present standard application plan of each department to use planning gas technical standard and gas utilization standard of introduction model than statute for change of self-regulation management system and complicated regulation of examination center and order.

  • PDF

Development of Risk Assessment Techniques for City Gas Pipeline II - Corrosion Analysis (도시가스배관 위험평가기술 개발 II - 부식 평가)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.1-6
    • /
    • 2003
  • In this work, procedure evaluating failure modes such as pipe rupture, large scale leak, and small scale leak was suggested using equations to assess remaining strength by corrosion failure. Additionally, the method to predict probability of failure was suggested according to the aforementioned failure modes, and by combining data on corrosion rate, probability of long-term failure can be induced. This work will be very useful in predicting lifetime or exchanging period of pipeline.

  • PDF

An Analysis of Gas Accident between 1995 and 1998, and Suggestion of Accident Reduction Countermeasures. (1995 ${\~}$ 1998년 가스사고 분석 및 사고감소대척 제시)

  • Park Kyo-Shik;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.1-8
    • /
    • 2000
  • It is required that gas accidents should be managed carefully as the consumption of fuel gas increases and high pressure gas process becomes more complex, which may cause a catastrophic accident. Factors to cause accidents were investigated through a systematic analysis of gas accidents between 1995 and 1998, which could be applied to prepare countermeasures to reduce gas accidents. As a result, it was suggested that the effective countermeasures to gas accidents should be kept applied, while new countermeasures were suggested in the field of increasing or not-decreasing number of accident. Totally 2,027 of accidents were reported during this term, and were found to decrease by about $12\%$ every year from 1996. The number of fuel gas such as LPG and city gas accident took up $96\%$, and most of accidents occurred at end-user's facility such as residential house and restaurant business. According to the kind of gas and facility, trend of accident by cause varies, while dominant causes are defective installation, appliance failure, or user's carelessness. Intentional accidents by fuel gas was excluded in this study because of its occurring mechanism and will be analyzed further elsewhere, although it took up $15\%$ and increased by $38\%$ every year.

  • PDF

A Study on the Effect of New Technology for Gas Safety Management (신기술 도입이 가스안전관리에 미치는 영향에 관한 탐색적 연구)

  • Kim, Byung-Keun;Ha, Tae-Young;Cho, Hyun-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.26-31
    • /
    • 2010
  • This paper aims to analyze the effect of the introduction of new technology and education for gas safety on the prevention of gas accidents. For the purpose of a study, inspections, safety tests and training programs conducted by KGS were examined and the gas accident data, installation rate of safety devices and training, inspection data for last 20 years were also collected and then Multiple regression analyses were performed by using SPSS. The results showed that in both of City Gas and LPG system, the installation rate of fusecocks and training programs were statistically meaningful for reducing the gas accident rate.

Prediction of Damage Area due to Explosion of LNG-Hydrogen Mixed Gas (도시가스-수소 혼합가스의 누출사고 영향범위 분석)

  • Chan-sik, Yoon;Jin-du, Yang;Gil-soo, Na;Sung-Hyun, Im;Ki-young, Kim;Eun-ki, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.27-34
    • /
    • 2022
  • The government is promoting various policies to reduce greenhouse gas emissions for carbon neutrality, one of the key tasks is to revitalize the hydrogen economy. As one of these policies the government has formulated a plan to incorporate hydrogen into existing city gas pipes, and aims to commercialize 20% hydrogen mixing by 2026. In preparation for the commercialization of city gas and hydrogen mixture, this study quantitatively predicts the scale of damage and the range of impact in the event of leakage of these two gas mixtures. The quantitative damage prediction method is to calculate the damage conversion distance through the calculation of the TNT equivalent by setting the leakage amount of the gas mixture in the event of an accident under a virtual scenario.

Study on Probabilistic Analysis for Fire·Explosion Accidents of LPG Vaporizer with Jet Fire (Jet Fire를 수반한 국내외 LPG 기화기의 화재·폭발사고에 관한 확률론적 분석에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • This study collected 5,100 cases of gas accident occurred in Korea for 14 years from 1995 to 2008, established Database and based on it, analyzed them by detailed forms and reasons. As the result of analyzing the whole city gas accidents with Poisson analysis, the item of "Careless work-Explosion-Pipeline' showed the highest rate of accidents for the next 5 years. And, "Joint Losening and corrosion-Release-Pipeline" showed the lowest rate of accident. In addition, for the result of analyzing only accidents related to LPG vaporizer, "LPG-Vaporizer-Fire" showed the highest rate of accident and "LPG-Vaporizer-Products Faults" showed the lowest rate of accident. Also, as the result of comparing and analyzing foreign LPG accident accompanied by Jet fire, facility's defect which is liquid outflow cut-off device and heat exchanger's defect were analyzed as the main reason causing jet fire, like the case of Korea, but the number of accidents for the next 5 years was the highest in "LPG-Mechanical-Jet fire" and "LPG-Mechanical-Vapor Cloud" showed the highest rate of accidents. By grafting Poisson distribution theory onto gas accident expecting program of the future, it's expected to suggest consistent standard and be used as the scale which can be used in actual field.

Study on Predictable Program of Fire.Explosion Accident Using Poisson Distribution Function & Societal Risk Criteria in City Gas (Poisson분포를 이용한 도시가스 화재 폭발사고의 발생 예측프로그램 및 사회적 위험기준에 관한 연구)

  • Ko, Jae-Sun;Kim, Hyo;Lee, Su-Kyoung
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.6-14
    • /
    • 2006
  • The data of city gas accidents has been collected and analysed for not only predictions of the fire and explosion accidents but also the criteria of societal risk. The accidents of the recent 11 years have been broken up into such 3 groups roughly as "release", "explosion", "fire" d 16 groups in detail. Owing to the Poisson probability distribution functions, 'careless work-explosion-pipeline' and 'joint loosening & erosion-release-pipeline' items respectively have turned out to record the lowest and most frequency among the recent 11-years accidents. And thus the proper counteractions must be carried out. In order to assess the societal risks tendency of the fatal gas accidents and set the more obvious safety policies up, the D. O. Hogon equation and the regression method has been used to range the acceptable range in the F-N curve of the cumulative casualties. The further works requires setting up successive database on the fire and explosion accidents systematically to obtain reliable analyses. Also the standard codification will be demanded.

A Study on Accidents of Buried Pipeline Crossing River (하천통과 매설배관의 사고사례에 대한 연구)

  • Ma, Young-Wha;Kim, Ji-Yun;Yoon, Kee-Bong;Do, Young
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.51-56
    • /
    • 2010
  • Records of accidents for buried pipeline across the river were gathered and causes were analysed. The results are intended to be utilized as basic data for determining a reasonable criteria for the depth of buried city gas pipeline crossing the river. Accident of river-crossing buried pipeline was mainly caused by flood. Sometimes corrosion was detected at the failed location of the pipe. In order to determine reasonable and efficient depth of burial of the pipeline, hydraulic evaluation of the river and structural analysis of the pipeline are necessary. Published data for the buried natural gas pipeline incidents were also investigated and summarized. Main causes of buried natural gas pipeline incidents were external interference and corrosion. However, the two main causes of incidents showed significant difference in the proportion of the entire incident, depending on burial environment.

A Study on the Actual Condition of Gas Equipment and Gas Safety Consciousness Survey to Improve Gas Safety of Gas Consumers (가스 소비자들의 가스안전성 제고를 위한 가스기기 사용 실태 및 가스안전의식 조사에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.465-475
    • /
    • 2017
  • As a result of a survey on households using gas, gas safety accidents have been declining linearly in 2006. However, when analyzing the causes of gas accidents, accidents detail caused by carelessness have increased to 62%It is analyzed that urgent measures are needed. In addition, 7 households per 10 households perceive city gas as safe, but 30% of them recognize that gas safety accidents are likely to occur in their homes in the future. Even though city gas use is relatively safe,It is recognized that there is a risk. Although the perception of the gas safety of the city gas consumers is not related to the age and gender income level, it is analyzed that it is highly educated and experienced direct or indirect gas safety accident, the perception of safety was relatively low. In order to reduce gas safety accidents, the installation of gas safety equipment for elderly households should be continuously supplied. As a result of investigating the disposal costs in case of various disasters, 66% of the insurance costs were found to be highly dependent on insurance. In addition, to reduce gas safety accidents, the installation of gas safety devices for elderly households should be continuously implemented.

Development of Sensor Module and Control System Software for LPG/CNG Stations (LPG/CNG용 센서 모듈 및 관제시스템 S/W 개발)

  • Cho, Beomsek;Kim, Sungkwang;Kim, Sungtae;Kim, Jongmin
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.53-59
    • /
    • 2018
  • In Korea, The number of installed LPG Charging stations is about 2000, increasing by 26 every year. In these, about 500 charging stations are older above 15 year, accounting about 25% of total stations. About 86% of them are located in the city, which is causing serious damage if accident occurs. In this paper, we developed a duel gas sensor module and integrated control system software that can prevent and correspondence to gas leaks and fire accidents at LPG/CNG charging stations. The dual type sensor module has the function of collecting and transmitting the measured data to the sensors of methane, butane and hydrogen through RF433Mhz communication. In addition, each sensor is attached with two to improve stability and accuracy. The integrated control system software detects real-time data of the devices measured by the sensors and it send to the PC and smart phone of manager. Therefore, if accident occurs, the manager can check the status of the charging station regardless of time and place.