• 제목/요약/키워드: circulating current

검색결과 310건 처리시간 0.028초

선망어법의 어획과정에 있어서 죔줄의 장력-I -망형별 죔줄의 장력에 관한 모형실험- (A Study on the Tension of a Purseline in the Process of Catch of the Purse Seine Fishing Methods-I -Model Experiment on the Tension of a Purseline by Net Shapes-)

  • 박정식
    • 수산해양기술연구
    • /
    • 제35권1호
    • /
    • pp.1-10
    • /
    • 1999
  • The north-west sea area of Cheju Island is where originate two layer current in the summer season. The case of the fishing operations in this sea area is almost impossible for normal expansion of the net gear for shooting net, and is happened to be frequent occasions for rise of tension suddenly in purseline by changes of the net shapes in the operation. Therefore, the safety of the operations is often obstructed by the above mentioned. In connection with the above, model experiments on the purse seine in the circulating water tank was carried out in comparison and analysis on the changes of tension in the pruseline by deformation of purse seine in the sea area of two layer current. THe results obtained are as follows;In the case of the required time for pursing of 20 minutes in the no current set, the increasing curve for tension of purseline can be expressed as:Y=0.0004x3+0.0098x2+0.3000x(r=0.9989)where Y is tension(metric tons) of a purseline, x is required time(minutes) for pursing. And, the maximum value of tension in this time was an increase of 31.3 percent at 15 minutes, and was a decrease of 30.3 percent at 30 minutes than that of 20 minutes.When the bottom margin of net is held on the position in velocity of 0.5 knot at three-eighths of net in the bottom current to the net height, the maximum tension of the required time for pursing of 30 minutes in tight set and loose set were decrease of 29.5 percent and 28.7 percent respectively than that of 20 minutes.The work load during the required time for pursing of 20 minutes were calculated 5.79×106 kgf·m in no current set, 7.89×106 kgf·m in tight set and 5.15×106 kgf·m in loose set, therefore it was an increase of 22.3 percent in tight set, and was a decrease of 11.1 percent in loose set than that of the no current set. Where tight set and loose set is a range of the bottom current with velocity of 0.5 knot at three-eighths of net to the net height.

  • PDF

온도차 및 부하 저항에 따른 열전모듈의 발전 특성 분석 (Experimental Study on the Power Generation of a Thermoelectric Module with Temperature Difference and Load Resistance)

  • 이공훈;김욱중;고득용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1942-1947
    • /
    • 2007
  • A thermoelectric module can be used for cooling or power generation. The basic requirements to achieve a significant thermoelectric performance are the same for both generators and coolers. Thermoelectric modules with $Bi_2Te_3$ materials are usually employed in the cooling applications below room temperature but it can also be used for the power generation in the similar temperature range. In the present study, the power generation with a $Bi_2Te_3$ thermoelectric module has been investigated. The temperature difference between the hot and cold sides of the module is maintained with electric heater and cold water from the circulating water bath. The result shows that the electric current generated increases with temperature difference and decreases with the load resistance. However, the voltage increases with both the temperature difference and load resistance. The electric power increases with temperature difference and it has the maximum value when the load resistance is about 4 ${\Omega}$ for a given device.

  • PDF

United Electromagnetic Characteristics and Online Monitoring Method of Static Air-gap Eccentricity of Turbo-Generator

  • Tang, Gui-Ji;Ke, Meng-Qiang;He, Yu-Ling;Wang, Fa-Lin
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1614-1627
    • /
    • 2016
  • The purpose of this paper is to investigate the united Electromagnetic characteristics for the effective monitoring on the static air-gap eccentricity (SAGE) of turbo-generator. Different from other studies, this paper not only studies on the unbalanced magnetic pull (UMP) and the vibration characteristics of the stator and the rotor, but also investigates the harmonic features of the magnetic flux density and the circulating current inside the parallel branches (CCPB). The theoretical calculation, together with the finite-element-method (FEM) simulation and the experiment verification, is taken for a SDF-9 type non-salient generator. It is shown that, when SAGE occurs, apparent double-frequency UMP and vibrations will be produced both on the stator and the rotor, while the CCPB will have an obvious increment at the $1^{st}$ harmonic component. In addition, the amplitude of the magnetic flux density will be of cosine distribution in the circumferential position of the air-gap, while in normal condition it is a constant. Moreover, the pass-band amplitude, together with the $1^{st}$ harmonic of the magnetic flux density, will be enlarged as well. These united electromagnetic characteristics can be used as the diagnosis and monitoring criterion for SAGE.

Novel Control of a Modular Multilevel Converter for Photovoltaic Applications

  • Shadlu, Milad Samady
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.103-110
    • /
    • 2017
  • The number of applications of solar photovoltaic (PV) systems in power generation grids has increased in the last decade because of their ability to generate efficient and reliable power in a variety of low installation in domestic applications. Various PV converter topologies have therefore emerged, among which the modular multilevel converter (MMC) is very attractive due to its modularity and transformerless features. The modeling and control of the MMC has become an interesting issue due to the extremely large expansion of PV power plants at the residential scale and due to the power quality requirement of this application. This paper proposes a novel control method of MMC which is used to directly integrate the photovoltaic arrays with the power grid. Traditionally, a closed loop control has been used, although circulating current control and capacitors voltage balancing in each individual leg have remained unsolved problem. In this paper, the integration of model predictive control (MPC) and traditional closed loop control is proposed to control the MMC structure in a PV grid tied mode. Simulation results demonstrate the efficiency and effectiveness of the proposed control model.

EV와 NEV 겸용 50kW급 고효율 모듈형 급속충전기 개발 (Development of 50kW High Efficiency Modular Fast Charger for Both EV and NEV)

  • 김민재;김연우;요스 프라보우;최세완
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.373-380
    • /
    • 2016
  • In this paper, a 50-kW high-efficiency modular fast charger for both electric vehicle (EV) and neighborhood electric vehicle (NEV) is proposed. The proposed fast charger consists of five 10-kW modules to achieve fault tolerance, ease of thermal management, and reduce component stress. Three-level topologies for both AC-DC and DC-DC converters are employed to use 600V MOSFET, resulting in ease of component selection and increase in switching frequency. The proposed three-level DC-DC converter with coupled inductor and its hybrid switching method can reduce the circulating current under wide output voltage range. A 50-kW prototype of the proposed fast charger was developed and tested to verify the validity of the proposed concept. Experimental results show that the proposed fast charger achieves a rated efficiency of 95.2% and a THD of less than 3%.

전기자동차용 배터리의 CC/CV 충전을 위한 새로운 듀얼 풀브리지 LLC 공진형 컨버터 (A Novel Dual Full-Bridge LLC Resonant Converter for CC/CV Charge of the Battery for Electric Vehicles)

  • 부하이남;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.337-338
    • /
    • 2016
  • This paper introduces a novel dual Full-Bridge LLC(FBLLC)resonant converter for CC/CV Charge of the Battery for Electric Vehicles. One full-bridge LLC resonant converter operates with a fixed-resonant network and the other operates with a variable-resonant network for CC and CV mode operations. The proposed converter can achieve ZVS for all the primary switches and exhibits a highefficiency characteristics like aconventional single FBLLC resonant converter. In addition, the variable-resonant network helps minimize the switching-frequency variation. The dual structure makes the proposed converter possible to achieve ZVS and nearly ZCS for all the primary switches in CC mode operation. Since the proposed converter can operate at a fixed frequency in CV mode, it can minimize the circulating current and achieve nearly ZCS. A 6.6 kW prototype converter is implemented to verify the validity of proposed converter and the maximum efficiency of 98.3% was achieved.

  • PDF

Cellular Contributors to Hypothalamic Inflammation in Obesity

  • Lee, Chan Hee;Suk, Kyoungho;Yu, Rina;Kim, Min-Seon
    • Molecules and Cells
    • /
    • 제43권5호
    • /
    • pp.431-437
    • /
    • 2020
  • The hypothalamus is a crucial organ for the maintenance of appropriate body fat storage. Neurons in the hypothalamic arcuate nucleus (ARH) detect energy shortage or surplus via the circulating concentrations of metabolic hormones and nutrients, and then coordinate energy intake and expenditure to maintain energy homeostasis. Malfunction or loss of hypothalamic ARH neurons results in obesity. Accumulated evidence suggests that hypothalamic inflammation is a key pathological mechanism that links chronic overconsumption of a high-fat diet (HFD) with the development of obesity and related metabolic complications. Interestingly, overnutrition-induced hypothalamic inflammation occurs specifically in the ARH, where microglia initiate an inflammatory response by releasing proinflammatory cytokines and chemokines in response to excessive fatty acid flux. Upon more prolonged HFD consumption, astrocytes and perivascular macrophages become involved and sustain hypothalamic inflammation. ARH neurons are victims of hypothalamic inflammation, but they may actively participate in hypothalamic inflammation by sending quiescence or stress signals to surrounding glia. In this mini-review, we describe the current state of knowledge regarding the contributions of neurons and glia, and their interactions, to HFD-induced hypothalamic inflammation.

촉매성 산화물 전극 (DSA, Dimensionally Stable Anode)의 가속수명 테스트 방법과 장치에 관한 기초 연구 (A Basic Study on Accelerated Life Test Method and Device of DSA (Dimensionally Stable Anode) Electrode)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.467-475
    • /
    • 2018
  • The lifetime of the electrode is one of the most important factors on the stability of the electrode. Since the lifetime of the DSA (Dimensionally stable anode) electrode is long, an accelerated lifetime test is required to reduce the test time. Beacuse there is no basis or standard method for accelerated lifetime testing, many researchers use different methods. Therefore, there is a need for basis and methods for accelerated lifetime testing that other researchers can follow. We designed a reactor system for accelerated lifetime testing and planned specific methods. Reactor system was circulating batch reactor. Reactor volume and cooling water tank were 12.5 L and 100 L, respectively. Electrode size was $2cm{\times}3cm$ (real electrolysis area, $5cm^2$). In order to maintain the harsh conditions, accelerated lifetime test was carried out in a high current density ($0.6A/cm^2$) and low electrolyte concentration (NaCl, 0.068 mol/L). Maintaining a constant temperature was an important operation parameter for exact accelerated lifetime test. As the accelerated lifetime test progressed, the active component of electrode surface was consumed and desorption occurred. At the point of 5 V rise, corrosion of the surface of the base material(titanium) also started.

골개형(Bone Remodelling)의 분자생물학적 기전에 대한 노화, 에스트로젠 및 산화적 스트레스의 영향 (Effects of Estrogen, Aging and Oxidative Stress on Bone Remodelling in a View of Molecular Mechanisms)

  • 박영철;고영도;한정호;김미경
    • Toxicological Research
    • /
    • 제22권3호
    • /
    • pp.253-266
    • /
    • 2006
  • Bone is a dynamic tissue that is constantly being remodelled. Resolution of bone and formation of new bone are closely linked, so that bone mass remains constant. With age, this process becomes unlinked with an imbalance in bore resorption and formation that results in a net loss of bone. Especially, osteoporosis is a disease characterized by low bone mass with age. One form of aging-related primary osteoporosis is postulated with the reduction of circulating estrogen, rapid bone loss occurs as a result of enhanced bore remodelling with an excess of resorption over bore formation. The oxidative stress is also involved in the pathogenesis of osteoporosis. Oxidative stress by cytokines, such as IL-a and TNF-${\alpha}$, inhibits osteoblast function in vitro and stimulates osteoblast apoptosis resulting in an imbalance in bore remodelling. The present article reviews the current perspectives on the interaction between bone remodelling and factors such as estrogen and oxidative stress, providing an interpretation of bone diseases in a view of molecular mechanisms.

Droop Control을 이용한 3상 4선식 UPS의 병렬운전 (Parallel Operation of Three-Phase Four wire UPS using Droop Control)

  • 김현섭;한정호;송중호
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.88-95
    • /
    • 2013
  • A new droop control method which can be applied to 3-phase 4-wire uninterruptible power supply is proposed in this paper. The droop control method for parallel operation is very attractive one as UPS parallel operation can be carried out without any data communication devices provided among UPS systems connected, but it reportedly shows a PnP(plug-and-play) problem. A basic reason why a circulating current could flow among parallel-connected UPS systems is clearly investigated as well when droop-controlled-ups systems are operated in the manner of PnP. The proposed algorithm is deduced from the investigated result and is basically structured to keep a balanced frequency and balanced voltage profile against power variation. This paper shows that balanced parallel operation of droop control method can be obtained under unbalanced load as well as balanced load conditions when PnP operation is needed and load change occurs.