• Title/Summary/Keyword: circuit-level model

Search Result 168, Processing Time 0.202 seconds

Development of EQM(Engineering Qualified Model) Local Oscillator far Ka-band Satellite Transponder (Ka-band위성 중계기용 국부발진기의 우주인증모델(EQM) 개발)

  • 류근관;이문규;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.335-344
    • /
    • 2004
  • A low phase noise EQM(Engineering Qualified Model) LO(Local Oscillator) has been developed for Ka-band satellite transponder. A VCDRO(Voltage Controlled Dielectric Resonator Oscillator) is also designed using a high impedance inverter coupled with dielectric resonator to improve the phase noise performances out of the loop bandwidth. The mechanical analysis fur housing and the thermal analysis fur circuit board are achieved. This EQM LO is applied to Ka-band satellite transponder of EQM level after environmental experiments for space application. The LO has the harmonic suppression characteristics above 52 ㏈c and requires low power consumption under 1.3 watts. The phase noise characteristics are exhibited as -101.33 ㏈c/㎐ at 10 ㎑ offset frequency and -114.33 ㏈c/㎐ at 100 ㎑ offset frequency, with the output power of 14.0 ㏈m${\pm}$0.17 ㏈ over the temperature range of -15∼+65$^{\circ}C$.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

The Effect of 4-Week Health Promotion Summer Camp on the Metabolic Syndrome and Insulin Resistance among Obese Elementary Students (비만 초등학생의 4주 여름 건강증진캠프 참여가 대사증후군 및 인슐린저항성에 미치는 효과)

  • Kim, Hee-Jung;Jekal, Yoonsuk
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.1117-1128
    • /
    • 2021
  • The purpose of the current study was to investigate the effects of 4-week health promotion intervention program consisting of high-intensity aerobic exercise to improve energy consumption and cardiorespiratory capacity, circuit training to strengthen muscular strength and endurance and education for lifestyle changes on the obesity level, physical fitness, insulin resistance and metabolic syndrome among overweight or obese elementary school students. Twenty three overweight or obese children as obese group and 15 normal body weight children as normal group were recruited. The health promotion program consisted of two exercise sessions and one education session, 3days/week in 4-week. Obesity level(body mass index, waist circumference, %body fat), physical fitness(muscular strength, muscular endurance, flexibility, cardiopulmonary fitness), insulin resistance(homeostasis model assessment of insulin resistance) and metabolic syndrome risk factors(blood pressure, fasting glucose, triglycerides, high density lipoprotein cholesterol) were measured. There was not significant decrease in obesity level; however, there were significant improvement in physical fitness, insulin resistance and metabolic syndrome risk factors after program participation among obese children. As a result, through participation in the summer camp consisting mainly of exercise, the improvement of the physical fitness level and the decrease of insulin resistance had an effect on the reduction of the metabolic syndrome frequency.

Dielectric Properties of Sardine-Starch Paste at Low Moisture Contents 1, Effect of Moisture Content and Frequency (정어리 마쇄육의 저수분에서의 유전특성 1. 수분함량과 주파업에 따른 유전특성)

  • LEE Byeong-Ho;KIM Chang-Yang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.2
    • /
    • pp.125-132
    • /
    • 1983
  • Dielectric properties of sardine-starch paste with moisture content of 4 to $13\%$ were investigated as functions of moisture and frequency. And the effects of the levels of fat and starch of the mixtures upon dielectric permittivity, critical moisture, were also mentioned. In addition, a theoretical prediction of frequency dependence of dielectric constant which was computed by the lumped circuit of two layer condenser model was evaluated. For the preparation of sardine-starch paste, comminuted sardine meat was washed thoroughly several times in chilled water by soaking and decanting, and finally centrifuged. This procedure was extended longer to provide a low fat sample. The centrifuged meat was mixed with adequate amounts of starch and salt, and ground for 25 minutes in a stone mortar, moulded in the form of disk with 7cm diameter and 1.2cm thickness and then freeze dried. Dried meat disks were cut off for the size of 5.5cm diameter and 1.0cm thickness and their moisture contents were controlled in humidified desiccators with saturated solutions. Dielectric constants of sardine-starch paste tended to decrease frequency was increased showing a critical charge at the moisture called critical moisture content. In case of the sample with $20\%$ starch and $2\%$ salt an average complex permittivity($\epsilon^{\ast}$) at 7 to $8\%$ morsture as the critical moisture content was presented; $\epsilon^{\ast}$=3.37+j 0.39 at 0.1 MHz, $\epsilon^{\ast}$=2.54+j 0.19 at 15 MHz, and $\epsilon^{\ast}$=2.15+j 0.08 at 1.8 GHz, respectively. The theoretically obtained complex permittivity values from the two layer condoner model were in close agreement with these actual measurements under the same conditions, that appeared as $\epsilon^{\ast}$=2.53+i 0.09 at 0.1 MHz and $\epsilon^{\ast}$=2.28+j 0.06 at 15 MHz, respectively. The fast level of the mixture also revealed an influence on dielectric property that defatted neat with $1.0\%$ fat showed a higher hc and $\epsilon^{\ast}$ value than the meat with $4.8\%$ fat. Complex permittivity being related to the moisture level remained nearly unchanged or slightly changed at the moisture range of 4 to $8\%$ but was dispersed widely at higher moisture contents.

  • PDF

Comparison of Achievable Efficiency for Different Resonator Structures in a Magnetic Resonance-based Wireless Power Transfer System (자기 공진 기반의 무선전력전송 시스템에서 송수신 공진기의 구조 차이에 따른 달성 가능한 효율 비교)

  • Lee, Kisong;Yang, Haekwon;Ra, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.1035-1041
    • /
    • 2017
  • In magnetic resonance-based wireless power transfer (WPT) systems, frequency splitting phenomenon, in which power transfer efficiency (PTE) decreases seriously as resonators are close to each other, is the problem that we should address for reliable power transfer in short distance. In this paper, we present WPT systems using an equivalent circuit model and analyze PTE and marginal coupling coefficient ($k_{split}$) where the frequency splitting occurs. In addition, we perform circuit-level simulations using Advanced Design System, and show that the achievable PTE is different for the structures of resonators when k>$k_{split}$. We confirm that higher PTE can be ensured as k increases in the case of identical resonators, while PTE is degraded as k increases in the case of non-identical resonators. Therefore, in short distance, in which k>$k_{split}$, it is more efficient for achieving reliable PTE to use identical resonators rather than non-identical resonators.

Design of a CAM-Type Traffic Policing Controller with minimum additional delay (시간지연을 최소화한 CAM형 트래픽 폴리싱 장치 설계)

  • 정윤찬;홍영진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.604-612
    • /
    • 2000
  • In order to satisfy the desired QoS level associated with each existing connection, ATM networks require traffic policing during a connection. Users who respect the contract should receive the function of transparent traffic policing without any interruption. However, contract violations should be detected and mediated immediately. So we propose a CAM type policing controller to allow user cell streams to minimize additional delay. The proposed policing scheme controls policing actions including traffic shaping by suitably spacing cells on each virtual circuit. This policing action is based on parallel processing of multiple cell stream which arrive in ATM multiplexed virtual circuits. We have developed an analytical model of the proposed policing scheme to examine the amount of cell loss and delay, which depends on traffic load, the size of policing buffers and minimum spacing cell time.

  • PDF

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

An Adaptive Setting Method for the Overcurrent Relay of Distribution Feeders Considering the Interconnected Distributed Generations

  • Jang Sung-Il;Kim Kwang-Ho;Park Yong-Up;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Lee Seung-Jae;Oshida Hideharu;Park Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.357-365
    • /
    • 2005
  • This research investigates the influences of distributed generations (DG), which are interconnected to the bus by the dedicated lines, on the overcurrent relays (OCR) of the neighboring distribution feeders and also proposes a novel method to reduce the negative effects on the feeder protection. Due to the grid connected DG, the entire short-circuit capacity of the distribution networks increases, which may raise the current of the distribution feeder during normal operations as well as fault conditions. In particular, during the switching period for loop operation, the current level of the distribution feeder can be larger than the pickup value for the fault of the feeder's OCR, thereby causing the OCR to perform a mal-operation. This paper proposes the adaptive setting algorithm for the OCR of the distribution feeders having the neighboring dedicated feeders for the DG to prevent the mal-operations of the OCR under normal conditions. The proposed method changes the pickup value of the OCR by adapting the power output of the DG monitored at the relaying point in the distribution network. We tested the proposed method with the actual distribution network model of the Hoenggye substation at the Korea Electric Power Co., which is composed of five feeders supplying the power to network loads and two dedicated feeders for the wind turbine generators. The simulation results demonstrate that the proposed adaptive protection method could enhance the conventional OCR of the distribution feeders with the neighboring dedicated lines for the DG.

Design of ISM-band Folded Dipole Active Integrated Antenna (ISM 대역용 접힌 다이폴 능동 집적 안테나의 설계)

  • 이재홍;서종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1612-1619
    • /
    • 2001
  • This paper examines the design, implementation characteristics of a folded dipole active integrated antenna. Our goal was to minimize the physical size of RF circuit and its insertion loss, and to make the high frequency tuning easier by directly integrating the ISM(Industrial Scientific & Medical) band power amplifier and antenna. Non-linear model has been used for highly accurate simulation of the power amplifier. The maximum power level was found by using the Load pull method before an impedance matching was achieved. It is found that the total power-added efficiency(PAE) including the driving amplifier was 31.5% and that the transmit power was 13.7 dBm. We also found that the proposed scheme with the smaller antenna as compared with the existing dipole antenna has 23.7 dB total gain including the antenna gain. The suppression of the second harmonic signal to the fundamental signal with respect to the fundamental signal was found to be more than 30 dBc.

  • PDF

A Study of the Adaptive Control System (適應制御裝置에 關한 硏究)

  • Ha, Joo-Shik;Choi, Kyung-Sam;Kim, Seung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.19-31
    • /
    • 1979
  • Recently the adaptive control system, which keeps the control system always optimal by adjusting the control parameters automatically according to the variations of the plant parameters, have become very important in the field of control engineering. The adaptive control systems are usally composed of the plant identification, the decision of the optimal control parameters, and the adjustment of the control parameters. This paper deals with a method of the adaptive control system when PI or PID controller is used in the feed back control system. Its controlled object (the plant) is assumed to be described by the transfer function of $\frac{ke^{-LS}}{1+TS}$ where k, T and L are steady state gain, time constant and pure dead time respectively, and their values are variable in accordance with the change of environmental circumstance. It has been known that a pseudo-random binary signal is quite effective for the measurement of an impulse response of a plant. In adaptive control systems, however, the impulse response itself is not appropriate to determine the control parameters. In this paper, the authors propose a method to estimate directly the parameters of the plant k, T and L by means of the correlation technique using 3 level M-sequence signal as a test signal. The authors also propose a method to determine the optimal parameters of the PI or PID controller in the sense of minimizing the square integral of the control error in the feed back control system, and the values of the optimal parameters are computed numerically for various values of T and L, and the results are examined and compared with those of the conventional methods. Finally the above-mentioned two methods are combined and an algorithm to struct an adaptive control system is suggested. The experiments for the indicial responses by means of both the model of the temperature control system using SCR actuater and the analog simulations have shown good results as expected, and the effectiveness of the proposed method is verified. The M-sequence generator and the time delay circuit, which are manufactured for the experiments, are operated in quite a good condition.

  • PDF