• Title/Summary/Keyword: circuit protection

Search Result 633, Processing Time 0.03 seconds

The Design of 128 Channels Cardiac-Activation Pre-Amplifier (128 채널 심장전기도 전치 증폭기의 설계)

  • Yoo, Sun-Kook;Chang, Byung-Chul;Jung, Dong-Il;Han, Young-Oh
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.550-556
    • /
    • 2001
  • The computerized cardiac analysis system, which acquires and analyzes the electrical activation signal propagating along the surface of the heart, is indispensible equipment for the open heart surgery and electrical cardiac study. In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and isolation part. It has distinct features; high voltage protection, leakage current limitation, isolation and the maximization of common mode rejection ratio with respect to the half-cell potential difference due to different electrode materials. The final pre-amplifier circuit is assembled with 8 boards, each of which composing of 16 channels.

  • PDF

The Development of Power Measurement Circuit for Non-Linear Load (비선형 부하에 적용 가능한 전력 계측 회로의 개발)

  • Park, Jong-Chan;Kim, Byung-Jin;Kim, Soo-Gon;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.79-82
    • /
    • 2002
  • Non-linear loads are the sources of power systems harmonics, and the power quality is influenced by harmonics, Recently, the requirements of power quality is important. For the power quality problems. it is very important that the development of power measurement circuit for non-linear load. In this paper, it is discoursed on that high speed sampling circuit and efficient power analysis algorithms. The sampling circuit is implemented using FPGA. Since the power measurement circuit system is composed by FPGA and efficient power algorithms. it is practicable application that accurate power measurement, stable protection relaying, and low cost system configuring.

  • PDF

Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply (보조전원장치의 단락부하 차단기 개방을 위한 제어방법)

  • 황광철;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

A Trip Coil Fault Detection of Circuit Breaker (차단기 트립코일 이상감지 장치)

  • Youn, Ju-Houc;Lee, Jong-Hun;Park, Noh-Sik;Lee, Dong-Hea
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

Two-Stage Surge Protection Device with Varistor and LC Filter. (바리스터와 LC필터를 사용한 2단 서지보호장치)

  • Lee, B.H.;Kim, J.H.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

Fabrication and Characteristics of a Combination Surge Generator for Testing Shipboard Electrical Systems (선박전기설비 시험용 조합형 써 - 지발생장치의 제작과 특성)

  • 길경석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.387-392
    • /
    • 1997
  • This paper describes a combination surge generator for carrying out performance tests on the surge protection circuits of shipboard electrical systems. Pspice simulations were performed to decide the values of the parts required and to analyze the characteristics of the generator circuitry. The surge generator fabricated can produce four of the most common surge test waveforms : the O.5i/S/100kHz Ringwave, the 1.2/50$\mu$S voltage, the 8/20$\mu$S current, and the lO/lOOOi/S voltage wave¬forms specified in ANSI Std. C62. Source impedances of the surge generator are 12$\Omega$ in the O.5$\mu$S/100kHz mode, O.5$\Omega$ in the 1.2/50$\mu$S and 8/20$\mu$S mode, and 40$\Omega$in the l0/1000$\mu$S mode, and are determined by the ratio of the maxi¬mum open - circuit voltage to the maximum short - circuit current. Experimental results show that the surge generator provides most of the outputs required for the testing of the surge protection circuits on shipboard electrical systems.

  • PDF

Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF

A Low-Power and Small-Area Pulse Width Modulator y Light Intensity for Photoflash (광량 변화에 따른 저전력 작은 면적을 가지는 포토플래시 용 펄스폭 변조기)

  • Lee, Woo-Kwan;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.7
    • /
    • pp.17-22
    • /
    • 2008
  • This paper presents a low-power and small-area pulse width modulator by light intensity for photoflash. Light intensity controller is achieved by using capacitor, photodiode, and comparator. The proposed circuit designs digital circuit to reduce static power consumption except comparator. And IGBT driver has short circuit protection using delay cell. The pulse width modulator has the operating range of $V_{MS}$ from 0.5V to 2.5V and pulse width of output from 0.14ms to 1.65ms at 300Hz. The pulse width modulator fabricated in $0.35-{\mu}m$ CMOS technology occupies $0.85mm{\times}0.56mm$. This circuit consumes 3.0mW at 300Hz and 3.0V.

Developement of Radiation Measuring System using Wireless Communication (무선통신을 이용한 방사선측정 시스템 개발)

  • Lee, Bong-Jae;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.85-95
    • /
    • 1995
  • Radiation measuring system using wireless communication method with single channel has been diveloped and tested. In this system, radiation signals from GM tube are transformed into digital pulses in pulse processing circuit and modulated in FSK (frequency shift keying) circuit for digital communication and then wirelessly transmitted to a receiving unit. The digital pulses received are then demodulated in FSK circuit and converted into radiation dose/dose rate in the data acquisition unit to display on the screen of a personal computer. The performance of this system was evaluated by using both a pulse generator and a standard radiation source(Cs-137). In both cases, digital pulses with 5V were observed in pulse processing circuit without distortion of their shape through wireless communication system. The experimental results of radiation measurement by this system after several test-irradiation of GM detector to a standard radiation source(Cs-137), showed good agreement with irradiation dose rate within 10% difference, and proved that this system could be effectively utillized as radiation measuring instrument. It is expected that this wireless radiation measuring system developed for the first time in Korea, can be used as a radiation monitor as well as a personal dosimeter if we can further improve this system to adopt wireless multichannel communication system.

  • PDF