• Title/Summary/Keyword: circuit balancing

Search Result 130, Processing Time 0.023 seconds

An Improvement of Expendable Bathythermograph Measurement Mechanism for Anti-Submarine Warfare (대잠용 수온측정계 측정 메커니즘 개선)

  • Shin, Sang-Sik;Cho, Hwan Hwi;Park, Seung Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.301-310
    • /
    • 2014
  • Purpose: The purpose of this study is to improve a mechanism of expendable bathythermograph measurement by balancing wire resistances between plus wire part and minus wire part and by removing effects of sea water resistance between XBT(Expendable Bathythermograph) and temperature recorder. Methods: The problems are exactly found out through the analysis of XBT and temperature recorder circuit. A process of XBT manufacturing that balances wire resistances between plus wire part and minus wire part is added. Results: The results of this study are as follows; the complicated test process such as temperature accuracy test with a cistern is substituted with a simple process of XBT manufacturing such as balancing wire resistances between plus wire part and minus wire part. Then, the temperature accuracy tolerance of XBT is improved up to ${\pm}0.1^{\circ}C$. Conclusion: Consequently, balancing wire resistances and removing effects of sea water resistance improve temperature accuracy of XBT and reduce expensive and harassing process of XBT manufacturing.

Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM (STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상)

  • Kwon, Byung-Ki;Jung, Seung-Ki;Kim, Tae-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator (냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구)

  • Kim, Ho-Jin;Kim, Hyeong-Jin;Kim, Dong-Youn;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

Job Route Selection Model for Line Balancing of Flexible PCB Auto-Insertion Line (유연 PCB 자동삽입라인의 부하 평준화를 위한 작업흐름선택모델)

  • Ham, Ho-Sang;Kim, Young-Hui;Chang, Yun-Koo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.20 no.4
    • /
    • pp.5-21
    • /
    • 1994
  • We have described the optimal process route selection model for the PCB(printed circuit board) auto-insertion line. This PCB assembly line is known as a FFL(flexible flow line) which produces a range of products keeping the flow shop properties. Under FFL environments, we have emphasized the balancing of work-loads in order to maximize total productivity of PCB auto-insertion line. So we have developed a heuristic algorithm based on a work-order selection rule and min-max concept for the job route selection model.

  • PDF

Development of an Efficient Operation Method for PCB Assembly Line with 3 Gantry-Type Machines (3대의 갠트리 기계로 구성된 PCB조립라인의 최적운영 방안 연구)

  • Moon, Gee-Ju;Jeon, Moon-Gil
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.4
    • /
    • pp.138-144
    • /
    • 2010
  • This research deals with multiple Gantry-type assembly machines for the optimization of PCB assembly line. The automated assembly machine has 6 nozzles which can linearly move the X axis and the Y axis different from the turret type assembly machine. Each machine is optimized while considering the whole line balancing of three machines in assembly process simultaneously. Simulation models are developed using AutoMod for comparison study with single machine operation cases under various conditions such as types and total number of components to evaluate the proposed method.

Design of Voltage Balancing Circuit applied to Multiple Cells (다중셀에 적용된 전압안정화회로 설계)

  • Hwang H. S.;Nam J. H.;Jang D. K.;Choi J. H.;Sin I. S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.193-196
    • /
    • 2003
  • For a power source of usual electronic devices such as PDA, smart phone, UPS and electric vehicle, the battery made of serially connected multiple cells is generally used. In this case, if there are some unbalanced among cell voltages, the total lifetime and the total capacity of the battery are limited to a lower value. To maintain a balanced condition in cells, an effective method of regulating the cell voltage in indispensable. In this paper introduced a method for battery balancing system using dissipation in the resistance.

  • PDF

An Isolated Bidirectional Modular Multilevel DC/DC Converter for Power Electronic Transformer Applications

  • Wang, Zhaohui;Zhang, Junming;Sheng, Kuang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.861-871
    • /
    • 2016
  • With high penetration of renewable energies, power electronic transformers (PETs) will be one of the most important infrastructures in the future power delivery and management system. In this study, an isolated bidirectional modular multilevel DC/DC converter is proposed for PET applications. A modular multilevel structure is adopted as switching valves to sustain medium voltages to achieve modular design and high reliability. Only one high-frequency transformer is used in the proposed converter, which significantly simplifies the circuit and galvanic insulation design. A dual-phase-shift modulation strategy is proposed to regulate the output power and achieve a simple voltage balancing control. A down-scaled (2 kW/20 kHz) prototype is constructed to demonstrate the proposed converter and verify the control strategy. The experimental results comply with the theoretical analysis well, with the highest power efficiency reaching 97.6%.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

Dynamic Home Circuit Construction for Datacenter Networks Using LOBS-HC Ring

  • Tang, Wan;Yi, Bo;Yang, Ximi;Li, Jingcong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1606-1623
    • /
    • 2015
  • Optical switching will be applied in datacenter networks because electronic switching is costly and power-consuming. In this paper, considering the ring-based interconnection using optical switching in the core of a datacenter, we study the home circuit (HC) construction for the labeled optical burst switching with home circuit (LOBS-HC), a new paradigm trying to share wavelengths among the HCs from the same source. In particular, aiming to construct HCs dynamically and properly, a scheme named optimal path matching and symmetric HC matching (OPM-SHM) is proposed. The main idea of OPM-SHM is to dynamically construct HCs by sharing wavelength(s) not only among the same-source HCs but also with symmetric HCs which have different sources other than the original LOBS-HC features. The simulation results demonstrate that OPM-SHM achieves better performance than some other methods in terms of burst loss rate and wavelength utilization of physical links. More specially, it maintains good load balancing for the datacenter network using an LOBS-HC ring. In addition, due to the symmetric feature of SHM, the proposed scheme can decrease the upper bound of the average hop count of the routing paths to half of the ring size.

A High-Voltage Compliant Neural Stimulation IC for Implant Devices Using Standard CMOS Process (체내 이식 기기용 표준 CMOS 고전압 신경 자극 집적 회로)

  • Abdi, Alfian;Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.58-65
    • /
    • 2015
  • This paper presents the design of an implantable stimulation IC intended for neural prosthetic devices using $0.18-{\mu}m$ standard CMOS technology. The proposed single-channel biphasic current stimulator prototype is designed to deliver up to 1 mA of current to the tissue-equivalent $10-k{\Omega}$ load using 12.8-V supply voltage. To utilize only low-voltage standard CMOS transistors in the design, transistor stacking with dynamic gate biasing technique is used for reliable operation at high-voltage. In addition, active charge balancing circuit is used to maintain zero net charge at the stimulation site over the complete stimulation cycle. The area of the total stimulator IC consisting of DAC, current stimulation output driver, level-shifters, digital logic, and active charge balancer is $0.13mm^2$ and is suitable to be applied for multi-channel neural prosthetic devices.