• Title/Summary/Keyword: chrome ion

Search Result 22, Processing Time 0.029 seconds

A Study on the Extraction of Collagen and Separation of Chrome Ion from Leather Waste (피혁 폐기물로부터 collagen 추출과 크롬이온 분리에 관한 연구)

  • Lim, Bong-Ju;Lim, Nam-Uoong;Lim, Han-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 1998
  • The objective of this study is to investigate the optimum conditions of extracting collagen without chrome ion from the leather waste. The effect of temperature, pH, and the concentration of alkaline solution on the collagen extraction has been studied. The result indicated that the incipient denatured temperature of collagen measured by viscosity was $25^{\circ}C$ and the complete denatured temperature was $31.5^{\circ}C$. The optimum solubilization condition for temperature was between $15^{\circ}C$ and $20^{\circ}C$, pH was 1.5, the concentration of alkaline solution was 3% of sodium hydroxide. The almost complete chrome ion separation was possible around the pH of 1.5. The separation efficiency of chrome ion from tannery waste was more than 99.5%. Extraction efficiency of crude protein from leather waste was about 89.5%. The hydroxyproline and collagen content in the extracted crude protein were 8.53% and 63.62%, respectively.

  • PDF

Sanitary Chemical Conditions of Farmwaters in Choongcheongnam and Kangwon Province According to Spring and Summer (충청남도 및 강원도 목장지역 목장용수의 춘하절간 위생화학적 변화)

  • 이강문;박석기;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.4
    • /
    • pp.229-235
    • /
    • 1994
  • It is very important to investigate the sanitary chemical conditions of farmwaters used for cattle breeding in the dairy farms. For this purpose we examined pH, KMnO4 consumption, total hardness, chloride, sulfate, NH3-N, NO3-N, fluoride, lead, iron, manganese, cadmium, copper, zinc and chrome in the farmwaters sampled 2 times(spring and summer)in Choongcheongnam and Kangwon Province. The pH of farmwaters in Choongcheongnam and Kangwon Province was 6.49$\pm$0.09, 6.70$\pm$0.06, total hardness 90.21$\pm$7.07, 64.53$\pm$6.38 mg/ι, consumption of KMnO4 4.13$\pm$0.62, 4.34$\pm$0.26mg/ι, NO3-N 6.51$\pm$0.55, 3.61$\pm$0.58 mg/ι, chloride ion 20.51$\pm$1.99, 5.41$\pm$1.36 mg/ι and sulfate ion 6.61$\pm$1.02, 7.28$\pm$1.30 mg/ι, respectively. But NH3-N was scarcely detected. Fluoride, iron, lead, cadmium, zinc, manganese and chrome were not detected from the tested farmwaters. There was high significance between each other in total hardness, NO3-N, chloride ion and sulfate ion. There was regional and seasonal significance in only NO3-N but only regional significance in total hardness and chloride ion.

  • PDF

Iron-Chrome Crossover through Nafion Membrane in Iron-Chrome Redox Flow Battery (철-크롬 산화환원흐름전지에서 Nafion막의 철-크롬 Crossover)

  • Kim, Young-Sook;Oh, So-Hyeong;Kim, Eunbi;Kim, Dayoung;Kim, Seongji;Chu, Cheun-Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.24-28
    • /
    • 2018
  • The redox flow battery (RFB) is a large-capacity energy storage equipment, and the vanadium redox flow cell is a typical RFB, but VRFB is expensive. Iron-chrome RFBs are economical because they use low-cost active materials, but their low performance is a urgent problem. In this study, the crossover of iron and chromium ion through Nafion membrane and the stability of Nafion membrane in HCl solution were investigated. The permeability of iron and chrome ion through Nafion were $5.5{\times}10^{-5}$ and $6.0{\times}10^{-5}cm^2/min$, respectively, which was 18.9~20.7 times higher than that of vanadium ion ($2.9{\times}10^{-6}cm^2/min$). The crossover of iron and chromium ions were shown to be a cause of performance decrease in Iron-chrome RFB. As the temperature increases, the crossover increases rapidly (activation energy 38.8 kJ/ mol), indicating that operation at low temperature is a methode to reduce the performance loss due to crossover. Nafion membranes were relatively stable in 3 M HCl solution.

Determination of Basic Drugs with Ion-Selective Membrane Electrodes Using Ion-Exchanger (이온교환체 이온선택성 전극을 이용한 염기성의약품 정량)

  • 이지연;정문모;허문회;김은정;안문규
    • YAKHAK HOEJI
    • /
    • v.43 no.3
    • /
    • pp.289-293
    • /
    • 1999
  • Many poly (vinyl chloride : PVC) membrane electrodes were investigated for the determination of basic drugs, chlorpromazine, amitriptyline, nortriptyline, etc. These electrodes are based on the use of the ion-association complexes of the basic drugs with eriochrome cyanine R, chromoxane cyanine, chrome azurol S and picric acid as ion-exchange sites in a plasticized PVC matrix. All ion-exchangers except picrate complex were not proper for use, because those complexes in plasticized membrane were excluded into aqueous working solution. These drug electrodes show excellent Nernstian responses in the concentration ranges $10^{-2}~10^{-6}$ mol $dm^{-3}$. Their selectivity with respect to each other, as well as their work-able pH range have been investigated. The major advantages of the proposed methods are their simplicity and speed.

  • PDF

A Study on Solid Particle Erosion Characteristics of Surface Treated 12wt%Cr Steel for USC Power Plant (USC 화력발전소용 12wt%Cr강의 표면처리에 따른 고체입자침식특성에 관한 연구)

  • 엄기원;이선호;이의열
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.324-326
    • /
    • 2004
  • l2wt%Cr Steel has been applied on turbine bucket and nozzle partition material of power plant. Turbine bucket and nozzle get damaged by solid particle within steam, therefore they are protected by surface treatments such as ion nitriding, boriding and chrome carbide HVOF spray coating. In this study, solid particle erosion(SPE) characteristics after these surface treatments are examined at operating temperature 540$^{\circ}C$ and 590$^{\circ}C$ of fossil power plant and the mechanism of damage was studied. Erosion of 12wt%Cr steel is originated by micro cutting and that of boriding and chrome carbide HVOF spray is originated by these mechanism - repeating collision, crack initiation and propagation. As the results of SPE test at 540$^{\circ}C$ and 30$^{\circ}$ impact angle that is the most commonly occurred in power plant, Boriding had the best SPE -resistance property, Cr$_2$C$_3$-25(Ni20Cr) HVOF spayed and ion nitrided samples were also better than bare metals(l2wt%Cr Steels). At 590$^{\circ}C$ and 30$^{\circ}$ impact angle, Boriding had also the most superior characteristic and HVOF spay sample was better than bare metal.

  • PDF

A Study on the Content of Manganese and Chrome in the Ground Water in Seoul Area (Based on non-water supply area) (서울 일부지역 정호수의 망간, 크롬함량 조사연구 상수시설 미설치지역을 중심으로)

  • 구성회;우세홍;이성호;이부웅
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1974
  • A study was carried out to determine the content of Mn and Cr in the ground water in Seoul area, where municipal water supply system was not installed, from Nov. 1 to Nov. 30, 1973. In this study, authors examined the hardness, pH, water temperature and Cl ion to investigate the general conditions of the ground water. For this study, samples were collected from 46 wells which were located in outpart of Seoul city, and Mn and Cr were determined with the Spectronic-20. The following results were obtained: 1) Average value of the ground water conditions of the wells were 13.3$\circ$C in temperature, pH 6.3, hardness 159 ppm and Cl ion 41 ppm. 2) In the manganese concentration, the highest area was Yeongdeungpo-Ku(0.318 ppm), while the lowest area was Sungbuk-Ku(0.065 ppm) and the mean concentration of the whole district was 0.196 ppm. 3) In the chrome concentration, the highest area was Yeongdeungpo-Ku(0.031 ppm), while the lowest area was Dobong-Ku (trace) and the mean concentration of the whole district was 0.012 ppm.

  • PDF

Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter (Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가)

  • Shin, Yong Chul;Oh, Se Min;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

Assessment of chemical purity of [13N]ammonia injection: Identification of aluminium ion concentration

  • Kim, Ho Young;Park, Jongbum;Lee, Ji Youn;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.80-84
    • /
    • 2018
  • $[^{13}N]$Ammonia or $[^{13}N]NH_3$ is one of the most widely used PET tracer for the measurement of MBF. To produce $[^{13}N]NH_3$, devarda's alloy which contains aluminum, copper and zinc is used for the purpose of reduction from $^{13}N$-nitrate/nitrite to $[^{13}N]NH_3$. Since aluminum has neurotoxicity and renal toxicity, the amount of it should be carefully limited for the administration to the human body. Although USP and EP provide a way to identify the aluminum ion concentration, there are some difficulties to perform. Therefore, we tried to develop the modified method for verifying aluminum concentration of test solution. We compared color between test and standard solutions using chrome azurol S in pH 4.6 acetate buffer. We also tested color change of test and standard solutions according to pH, amounts and the order of reagent and time difference These results demonstrated that the color change of the solution can reflect quantitatively measure aluminum ion concentration. We hope the method is to be used effectively and practically in many sites where $[^{13}N]NH_3$ is produced.

Zinc Ions Affect Siderophore Production by Fungi Isolated from the Panax ginseng Rhizosphere

  • Hussein, Khalid Abdallah;Joo, Jin Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.105-113
    • /
    • 2019
  • Although siderophore compounds are mainly biosynthesized as a response to iron deficiency in the environment, they also bind with other metals. A few studies have been conducted on the impact of heavy metals on the siderophore-mediated iron uptake by microbiome. Here, we investigated siderophore production by a variety of rhizosphere fungi under different concentrations of $Zn^{2+}$ ion. These strains were specifically isolated from the rhizosphere of Panax ginseng (Korean ginseng). The siderophore production of isolated fungi was investigated with chrome azurol S (CAS) assay liquid media amended with different concentrations of $Zn^{2+}$ (50 to $250{\mu}g/ml$). The percentage of siderophore units was quantified using the ultra-violet (UV) irradiation method. The results indicated that high concentrations of $Zn^{2+}$ ion increase the production of siderophore in iron-limited cultures. Maximum siderophore production by the fungal strains was detected at $Zn^{2+}$ ion concentration of $150{\mu}g/ml$ except for Mortierella sp., which had the highest siderophore production at $200{\mu}g/ml$. One potent siderophore-producing strain (Penicillium sp. JJHO) was strongly influenced by the presence of $Zn^{2+}$ ions and showed high identity to P. commune (100% using 18S-rRNA sequencing). The purified siderophores of the Penicillium sp. JJHO strain were chemically identified using UV, Fourier-transform infrared spectroscopy (FTIR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF-MS) spectra.

Active Material Crossover through Sulfonated Poly (Ether Ether Ketone) Membrane in Iron-Chrome Redox Flow Battery (철-크롬 산화환원흐름전지에서 Sulfonated Poly (Ether Ether Ketone)막의 활물질 Crossover)

  • Kim, Young-Sook;Oh, So-Hyeong;Kim, You-Jeong;Kim, Seong-ji;Chu, Cheun-Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.17-21
    • /
    • 2019
  • The redox flow battery (RFB) is a large-capacity energy storage equipment, and the vanadium redox flow cell is a typical RFB, but VRFB is expensive. Iron-chrome RFBs are economical because they use low-cost active materials, but their low performance is an urgent problem. One of the reasons for the low performance is the crossover of the active materials. In this study, the sulfonated Poly (ether ether ketone) (sPEEK) membrane, which is a hydrocarbon membrane, was used instead of the fluorine membrane to reduce the crossover of the active materials. The chromium ion permeability of the sPEEK membrane was $1.8{\times}10^{-6}cm^2/min$, which was about 1/33 of that of the Nafion membrane. Thus, it was shown that the use of the sPEEK membrane instead of the fluorine membrane could solve the high active material crossover problem. The activation energy of iron diffusion through the sPEEK membrane was 24.9 kJ/mol, which was about 66% of Nafion membrane. And that the e-PTFE support in the polymer membrane reduces the active material crossover through Iron-Chrome Redox Flow Battery (ICRFB).