망간모래여과를 이용한 강변여과수의 망간제거 (Manganese Removal of Bank Filtrate using Manganese Sand Filtration)

  • 김충환;김학철;김한승;김범수;안효원
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.409-414
    • /
    • 2004
  • Pilot-scale experiments were performed for the treatment of bank filtrate contammg high manganese concentration around 2mg/L using rapid manganese sand filtration to investigate effects of oxidant dose and pH control on the removal efficiency of manganese. For theoretical dose ranges of oxidant (sodium hypochlorite) between 3 and 4mg/L, the manganese concentration of effluent was 0.57 mg/L, which corresponded to 72.5% removal and was higher than drinking water quality standards of 0.3mg/L. For excess dose ranges of oxidant between 4 and 8mg/L, the manganese concentration of effluent was reduced to 0.14mg/L, which corresponded to 94.5% removal, but the residual chlorine concentration was over 1.0mg/L. On the other hand, manganese removal efficiency drastically increased up to the value of 98.0%, which is equivalent to the effluent concentration of 0.03mg/L by controling pH to the range between 7 and 8 for the theoretical dose of oxidant. Consequently, these results indicated that appropriate dose of chemicals, such as oxidant and alkali, and continuous monitoring of manganese should be necessary to obtain efficient removal of manganese and to optimize the maintenance of treatment facilities for the treatment of bank filtrate with high concentration of manganese.

도토리박 추출물과 푸마르산 및 중온 열 병합처리에 의한 적근대의 미생물 제어 효과 (Combined Treatment of Acorn Pomace Extract, Fumaric Acid, and Mild Heat for Inactivation of Microorganisms on Red Chard)

  • 박신민;송경빈
    • 한국식품영양과학회지
    • /
    • 제45권11호
    • /
    • pp.1696-1700
    • /
    • 2016
  • 본 연구에서는 차아염소산 나트륨 같은 염소계 살균세척제를 대체하기 위한 천연 살균세척제로서 도토리박 추출물(APE)을 개발하기 위해 적근대에 Listeria monocytogenes를 접종한 후 APE의 항균 효과를 측정하였다. 그리고 최적 세척처리 조건을 수립하고자 APE, FA, $50^{\circ}C$에서의 mild heat를 병합처리하였다. 모든 처리구 중 0.5% APE/$50^{\circ}C$ mild heat/0.5% fumaric acid(FA) 병합 세척처리가 가장 효과적이었는데, L. monocytogenes 수를 대조구에 비해 3.36 log CFU/g 감소시켰다. 병합처리된 적근대 시료의 저장 8일 후 총 호기성균은 대조구와 비교하였을 때 2.89 log CFU/g 감소하였고, 색도 측정 결과 처리구 간 유의적인 차이가 나타나지 않았다. 따라서 본 연구 결과 APE/mild heat/FA 병합처리 방법은 수확 후 적근대의 품질에 영향을 미치지 않고 미생물학적 안전성을 높일 수 있는 효과적인 기술이라고 판단된다.

대장균과 황색포도상구균에 대한 이산화염소의 살균소독력 평가 및 살균예측모델 개발 (Evaluation of Efficacy and Development of Predictive Reduction Models for Escherichia coli and Staphylococcus aureus on Food Contact Surfaces as a Function of Concentration and Contact Time of Chlorine Dioxide)

  • 윤소정;박신영;김용수;하상도
    • 한국식품위생안전성학회지
    • /
    • 제32권6호
    • /
    • pp.507-512
    • /
    • 2017
  • 본 연구는 기구등에 오염된 E. coli와 S. aureus를 제어하기 위해 이산화염소의 농도별 접촉시간에 따른 살균소독력을 평가하여 살균예측모델을 개발하였다. E. coli의 경우 초기균수가 9.13 log CFU/mL이었고, 청정조건에서 5ppm으로 1분, 3분, 5분 처리한 결과 각각 0.04, 0.07, 0.10 log CFU/mL의 감소값을 나타내었다. 20 ppm을 처리한 결과 각각 0.74, 0.79, 0.84 log CFU/mL의 감소값을 나타내었다. 또한 CCD에 의한 최대농도 35 ppm으로 처리한 결과 각각 2.49, 2.70, 3.65 log CFU/mL의 감소값을 나타내었다. S. aureus의 경우 초기균수가 8.70 log CFU/mL이었고, 청정조건에서 5 ppm으로 1분, 3분, 5분 처리한 결과 각각 0.14, 0.28, 0.36 log CFU/mL의 감소값을 나타내었다. 20 ppm을 처리한 결과 각각 0.66, 0.79, 0.90 log CFU/mL의 감소값을 나타내었다. 또한 CCD에 의한 최대농도 35 ppm으로 처리한 결과 각각 4.59, 5.25, 5.81 log CFU/mL의 감소값을 나타내었다. 따라서 이산화염소의 살균소독력 평가결과는 E. coli와 S. aureus에 대하여 식품의약품안전처 살균소독력 기준에 모두 만족하는 것으로 나타났다. 살균예측모델의 경우, $R^2$값이 모두 0.98 이상으로 두 균주에 대해 모두 높은 적합성을 보였다. 본 연구에서 개발된 이산화염소의 살균예측모델을 식품산업 적용을 위한 기초자료로 활용함으로써 E. coli와 S. aureus를 적절한 농도와 접촉시간으로 제어할 수 있을 것으로 사료된다.

광주지역 바닥분수의 수질특성 평가 (Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju)

  • 김종민;김하람;장서은;최영섭;강유미;정숙경;조영관;김은선
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

채소 및 주방기구에 대한 강산성전해수의 살균효과 (Bactericidal Activity of Strongly Acidic Electrolyzed Water on Various Vegetables and Kitchen Apparatus)

  • 김윤정;최규덕;신일식
    • 한국식품영양과학회지
    • /
    • 제39권5호
    • /
    • pp.776-781
    • /
    • 2010
  • 격막식으로 생산한 강산성전해수(SEW)의 유효염소농도는 $35{\pm}1.2\;ppm$, pH는 $2.3{\pm}0.2$, ORP는 $1,140{\pm}20.4\;mV$이었으며, AEW의 유효염소농도는 $0.1{\pm}0.01\;ppm$, pH는 $11.6{\pm}1.1$, ORP는 $-900{\pm}18.2\;mV$이었다. 6종의 병원성세균(초기균수 $1.0{\times}10^7\;CFU/mL$)에 대한 SEW의 살균효과를 조사한 결과, 대조구로 사용한 유효염소농도 35 ppm의 차아염소산 나트륨 용액의 경우, 60초간 처리하여도 2~4 log 정도의 균밖에 감소하지 않았으나 SEW는 60초간 처리로 포자를 형성하는 B. cereus를 제외한 나머지 5종의 병원성세균을 모두 살균하였으며, B. cereus의 경우 완전하게 살균하지는 못하였지만 약 4 log CFU/g 이상이 감소하여, 같은 유효염소농도라도 SEW가 차아염소산나트륨 용액보다 살균력이 뛰어나다는 것을 알 수 있었다. 채소의 경우, AEW로 세척 후 SEW 처리하였을 때가 SEW 단독처리보다 살균효과가 더 좋았다. 한편 콩나물, 무순의 경우 AEW로 30초간 세척 후 SEW로 30초간 처리하여도 균수는 각각 $2.50{\pm}0.13$, $2.19{\pm}0.13$만 감소하였고 4 log CFU/g 이상의 균이 잔존하고 있었다. 식기와 컵은 차아염소산나트륨 용액(유효염소농도 35 ppm) 30초간 처리로는 1.19~1.28 log CFU/$100\;cm^2$ 정도만 감소하였지만, SEW 30초간 처리로 균이 검출되지 않았다. 고무장갑의 경우 유일하게 대장균군이 검출되었으며 SEW 30초간 처리로 고무장갑 표면의 일반세균과 대장균군은 대조군인 수도수에 비하여 약 2 log CFU/$100\;cm^2$ 이상 감소하였으나 완전한 살균은 되지 않았다.

강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구 (Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves)

  • 정원희;고준수;신일식
    • 한국식품위생안전성학회지
    • /
    • 제30권2호
    • /
    • pp.166-172
    • /
    • 2015
  • 본 연구는 강산성차아염소산수(SAHW)와 초음파(UW)를 병용한 조미오징어 반가공품의 미생물 오염도 저감 기술을 개발하고자 수행되었다. SAHW의 유효염소농도는 $69.67{\pm}0.58ppm$, ORP는 $1071.33{\pm}4.16mV$, pH는 $2.79{\pm}0.05$이었다. 오징어 반가공품을 중량대비 20배의 SHS에 120분간 침지하였을 때 일반세균은 1.49 log CFU/g, 황색포도상구균은 1.32 log CFU/g 감소하였으며, 대장균은 검출한계 이하로 감소하였다. 오징어 반가공품 중량대비 10배의 SAHW에 120분간 침지한 경우, 일반세균은 2.69 log CFU/g, 황색포도상구균은 1.74 log CFU/g 감소하였으며, 20배의 SAHW에 120분간 침지한 경우, 일반세균은 3.62 log lCFU/g, 황색포도상구균은 3.22 log CFU/g 감소하였으며, 대장균은 검출되지 않아 SAHW가 같은 유효염소농도의 SHS보다 살균력이 높은 것을 알 수 있었다. SAHW 단독 처리만으로는 만족할 만한 미생물 저감효과를 얻을 수 없었기에 조미오징어 반가공품을 SAEW에 1차 침지 처리한 후, SAHW에 2차 침지 처리한 결과, 오징어 반가공품 중량 대비 20배의 SAEW로 60분 처리한 후, SAHW로 처리하였을 때는 중량대비 10배, 120분 처리, 중량대비 20배, 90분 처리로 일반세균수는 약 4.0 log CFU/g, 황색포도상구균은 규제치(log 2.0 CFU/g 이하) 이하로 감소하였으며 대장균은 검출되지 않았다. 초음파 세정기에 오징어 반가공품과 중량대비 20배의 TW, SHS, SAHW를 각각 넣어 UW 처리한 후 미생물 오염도를 조사한 결과, SAHW로 60분간 처리하였을 때 일반세균은 검출한계(< 1.00 log CFU/g) 이하로 감소하였으며 황색포도상구균은 규제치 이하로 감소하여 가장 좋은 저감효과를 나타내었다. 대장균의 경우, SAHW 10분간 처리로도 검출한계 이하로 감소하여 SAHW와 UW의 병용이 조미오징어 반가공품 미생물 저감화에 가장 효과가 좋은 것을 알 수 있었다.