• Title/Summary/Keyword: chloride ion concentration

Search Result 300, Processing Time 0.031 seconds

Effect of Benzalkonium Chloride on Percutaneous Absoption of Antisense Phosphorothioate Oligonucleotides

  • Lee, Young-Mi;Lee, Sung-Hee;Ko, Geon-Il;Kim, Jae-Baek;Sohn, Dong-Hwan
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.435-440
    • /
    • 1996
  • The effect of benzalkonium chloride on skin permeability of partially modified antisense phosphorothioate oligonucleotides (PS-ODN), which are designed as scar formation inhibitor, was investigated using Franz Diffusion Cell. When the concentration ratio of PS-ODN-quarternary ammonium salt complex is more than 1:100, the apparent partition coefficient (APC) of each complex was increased in the following order; tetraphenyl phosphonium chloride (TPP) < cetyltrimethyl ammonium bromide(CTAB) < benzalkonium chloride (BZ). The permeability of PS-ODN through the rat skin increased in the presence of BZ. The fluxs of PS-ODN with BZ were increased by addition of Pluronic F 68 or Triton X-100 to phosphate buffered saline (PBS), respectively. When the mole ratio of PS-ODN to BZ is 1:10, the fluxs penetrated of PS-ODN with BZ was greatest. The increase of the permeability in the presence of BZ might be due to the formation of lipophilic ion-pair complex between PS-ODN and BZ. By regulation of mole ratio of PS-ODN to BZ, the development of topical dosage forms using PS-ODN as scar formation inhibitor will be possible with minimal systemic exposure.

  • PDF

Enhanced Classical Tafel Diagram Model for Corrosion of Steel in Chloride Contaminated Concrete and the Experimental Non-Linear Effect of Temperature

  • Hussain, Raja Rizwan
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.2
    • /
    • pp.71-75
    • /
    • 2010
  • The chloride ion attack on the passive iron oxide layer of reinforcement steel embedded in concrete under variable temperature environment is influenced by several parameters and some of them still need to be further investigated in more detail. Different school of thoughts exist between past researchers and the data is limited in the high temperature and high chloride concentration range which is necessary with regards to setting boundary conditions for enhancement of tafel diagram model presented in this research. The objective of this paper is to investigate the detrimental coupled effects of chloride and temperature on corrosion of reinforced concrete structures in the high range by incorporating classical Tafel diagram chloride induced corrosion model and laboratory controlled experimental non-linear effect of temperature on corrosion of rebar embedded in concrete.

Evaluation on Chloride Attack by Colormetric Method in Marine Concrete Structures. (변색법을 활용한 해양 콘크리트 구조물의 염해평가)

  • Park, Jin-Ho;Kim, Myung-Yu;Kwak, Sang-Yun;Yang, Eun-Ik;Park, Hae-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.181-184
    • /
    • 2005
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the seawater. Because the damages of corrosion resulting from the chloride ion are very serious, many researches have been performed. However evaluation on chloride attack of concrete structures are not fully examined, recently. Therefore, the objective of this paper is to study the applicability of colormetric method. For the purpose of this, reaction mechanism of colormetric method were investigated, and the colormetric method is applied for marine concrete structures. According to the test results, the diffusion coefficient by colormetric method is not so different to the value of chloride concentration profile test. It is confirmed that the colormetric method is useful tool for estimating the chloride of concrete structures in situ. The average chloride amount of colored parts indicates 0.9kg/$m^{3}$ per concrete unit weight.

  • PDF

Removal Characteristics of Cu(II) ion in Aqueous Solution by Solid-Phase Extractant Immobilized D2EHPA and TBP in PVC (D2EHPA와 TBP를 PVC에 고정화한 고체상 추출제를 사용한 수용액 중의 Cu(II) 이온 제거특성)

  • Kam, Sang-Kyu;Lee, Song-Woo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.24 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Removal characteristics of Cu(II) ions by solid-phase extractant immobilized D2EHPA and TBP in PVC were investigated. Cu(II) ion concentrations in the solution and removal capacity of Cu(II) ion according to operation time were compared. The lower the initial concentration of Cu(II) ion in aqueous solution was, the removal capacity of Cu(II) ion by solid-phase extractant was increased relatively. The bigger the initial concentration of Cu(II) ion was, the removal capacity of Cu(II) ion was increased relatively. The pseudo-second-order kinetics according to operation time was showed more satisfying results than the pseudo-first-order kinetics for the removal velocity of Cu(II) ion. The removal capacity of Cu(II) ion was 0.025 mg/g in aqueous solution of pH 2, but the removal capacity of Cu(II) ion was increased to 0.33 mg/g mg/g in aqueous solution of pH 4 according to increasing pH.

Ion Exchange of Gold(III) from Ammonium Chloride Solution by Anionic Resins (염화암모늄용액에서 음이온 교환수지에 의한 금(III)의 이온교환)

  • Ahn, Hyeong Hun;Lee, Man Seung
    • Resources Recycling
    • /
    • v.27 no.2
    • /
    • pp.48-54
    • /
    • 2018
  • Batch ion exchange experiments of Au(III) were performed from ammonium chloride solution by employing strong anionic exchange resins (Amberlite IRA 402 and AG 1-X8). Au(III) was well loaded into the two resins and the loading behavior of Au(III) into AG 1-X8 was superior to that into Amberlite IRA 402. The loading of Au(III) into AG 1-X8 followed Langmuir adsorption isotherm and the experimentally determined loading capacity was 355 mg/g. Au(III) was successfully eluted by $HClO_4$ from the loaded AG 1-X8 and the elution percentage of Au(III) increased with the concentration of $HClO_4$.

Evaluation on Design Factors of Electrolytic Flotation Reactor by Measuring Polarization Curve (분극곡선 측정을 통한 전해부상조의 설계인자 평가)

  • Lim, Bong-Su;Jin, Jing-Zhu;Choi, Chan-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.244-250
    • /
    • 2007
  • This study was carried out to obtain the optimum design factors for an eletrolytric flotation reactor. When the effluent of the leachate treatment facility was treated under the condition of 10 volts, 30 minutes, at the Al-Al electrode system; COD removal efficiency was 45%, and total phosphorus removal efficiency was 98%. The high removal efficiency was caused by the fact that phosphate was removed by leaching $Al^{3+}$ from two electrodes. The leachate containing high ammonium nitrogen concentration was treated by a batch test under the condition of 60 minutes reaction time and added chloride ion; ammonium nitrogen removal efficiency was 89%. This high efficiency was affected by added chloride ion to wastewater. To find the optimum current density and voltage of the leachate containing chloride ion (ratio of $Cl^-/NH_4-N$ is 11) a electrochemical polarization curve was used. These values were found to be $4.5mA/cm^2$ and about 2.1 V, respectively. When C-Al electrode system was used at a batch test, the total nitrogen removal efficiency was increased by 1.8 to 3.3 times, compared to Al-Al electrode system due to high $Cl_2$ gas production.

Effects of C3A Content on Chloride Concentration in Pore Solution (C3A함유량이 세공용액 Cl 농도에 미치는 영향)

  • 소승영;박홍신;소양섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.1
    • /
    • pp.89-96
    • /
    • 1995
  • 본 연구는 시멘트 경화체 중의 Cl 고정화 메카니즘을 규명하는 연구의 일환으로 시멘트의 C3A 함유량에 따른 Cl 고정화 효과를 세공용액 분석방법에 의해 조사한 것으로 C3A함유량 0.46 9.65%의 4가지 시멘트와 C3A를 함유하지 않은 초속경 시멘트 페이스트를 밀봉용기내에서 양생시켜 재령 28일에 세공용액을 추출하여 세공용액 중의 Cl 과 OH 농도를 측정, C3A함유량이 Cl 고정화에 미치는 영향을 검토한 것이다. 연구결과 세공용액 중의 Cl 농도는 NaCl 혼입량에 관계없이 시멘트 중의 C3A량이 증가함에 따라 낮아져 시멘트 경화체 내에서 Cl 의 고정화에 C3A가 매우 효과적임을 알 수 있었다. 세공용액의 Cl /OH 는 Cl 혼입량이 시멘트 중량의 0.3%인 경우 강재부동태막을 파괴하는 0.3보다 낮았으며 X선회절분석에 의해 C3A에 의한 고정화 메카니즘은 프리델씨염(Friedel's salt)의 생성에 의함을 확인하였다.

Measurement of an Ion Concentration in Drinking Water by lon Chromatography (Ion Chromatography에 의한 음료수중 음이온 함량에 관한 연구)

  • Kim Hyung-Suk
    • Journal of environmental and Sanitary engineering
    • /
    • v.4 no.1 s.6
    • /
    • pp.7-15
    • /
    • 1989
  • According to the increase of population and development of industrialization air and water pollution problems are still keeping going to great nuisance to human activities. Specially man should drink 2l clean water to maintain our health every day, but we afraid of drink the city tap water because of the contaminants like heavy metals, bacteria trihalomethane, etc. In the analysis of the anions in potable water, we usually adapt the Standard methods for the Examination of Water and Wastewater. But this method is tedious and time consuming, so the Ion Chromatography method is now used in research of water quality. Author worked with Ion Chromatography in measuring the anions in drinking water by attaching conductivity dector to normal High Performance Liquid Chromatograph. Low-capacity ion-exchange coulmn and dilute eluents, 0.00M phthalic aic was used in this study. The concentration of chloride ion was 1.55 ppm$\~$3 8.81ppm, nitrate ion was 5.45 ppm$\~$18.27ppm, and sulfate ion was 19.64 ppm$\~$28.86 ppm. The phosphate ion was detected only in Apt. tap water as 167.99 ppm whose amount was supposed to be used as a water pipe cleaner.

  • PDF

Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone (기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향)

  • Choi, Yong-Sun;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.

Study on the Critical Threshold Chloride Content for Steel Corrosion in Concrete with Various Cement Contents (단위시멘트량이 다른 콘크리트 중에서의 철근부식 임계염화물량에 관한 연구)

  • Yang, Seung-Kyu;Kim, Dong-Suck;Um, Tai-Sun;Lee, Jong-Ryul;Kono, Katsuya
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.415-421
    • /
    • 2008
  • Reinforced concrete starts to corrode when the chloride ion concentration which is the sum of included in concrete and penetrated from environments exceeds a certain level of critical chloride concentration. Therefore each country regulates the upper bounds of chloride amount in concrete and the regulations are different for each country due to its circumstances. In this study, the critical threshold chloride content according to unit cement amount is empirically calculated to propose a reasonable regulation method on the chloride amount. As a result, the critical threshold chloride content increases considerably according to cement content and it agrees with the established theories. The present regulations on total chloride amount 0.3 or 0.6 kg chloride ions per $1\;m^3$ of concrete does not reflect the influences of mix design, environmental conditions and etc. So it can be said that it is more reasonable to regulate the critical threshold chloride content by the ratio of chloride amount per unit cement content than by the total chloride content in $1\;m^3$ of concrete.