• Title/Summary/Keyword: chloride ion concentration

Search Result 300, Processing Time 0.029 seconds

Fracture Analysis Considering the Non-uniform Corrosion Distribution (비선형 부식분포를 고려한 철근덮개 파괴해석)

  • 오병환;장봉석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1041-1044
    • /
    • 2001
  • This study was performed to evaluate the effect of non-uniform corrosion distribution on the analysis of concrete cover failure. A series of experiments have been undertaken to measure the corrosion rate of reinforcement according to the concentration of chloride ion so as to suggest a relationship between the reinforcement corrosion rate and chloride ion density. The corrosion induced pressure depending on the density of chloride ion has been derived. And nonlinear analysis assuming nonlinear corrosion distribution for cover cracking was achieved and compared with other experimental results to verify the accuracy of the model. Analysis was also performed for various parameters to compare their effects.

  • PDF

The Characteristics of Chloride Fixation in Non-Sintering Cement Matrix (비소성 시멘트 경화체내 염화물 고정화 특성)

  • Mun, Kyoung-Ju;Hyoung, Won-Kil;Park, Won-Chun;So, Seung-Young;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.725-728
    • /
    • 2006
  • This research investigates the characteristics of chloride fixation in non-sintering cement(NSC) matrix. NSC was manufactured by adding phosphogypsum and slack lime to granulated blast furnace slag as sulfate and alkali activators. As a result, the concentration of chloride ion in pore solution of NSC-solidified matrix is more low than that of OPC-solidified matrix containing the same chloride content in cement paste. Also, the concentration of chloride ion in pore solution of NSC-solidified matrix is similar with that of BSC-solidified matrix containing the same chloride content in cement paste.

  • PDF

Nitrogen Removal by Electrochemical Oxidation Using the Tube Type Electrode (튜브형 전극을 이용한 전기화학적 산화에 의한 질소제거에 관한 연구)

  • Cho, Jae-Jun;Jeong, Jong-Sik;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.580-587
    • /
    • 2004
  • The objective of this research is to investigate the electrochemical oxidation process for nitrogen removal in wastewater involving chloride ion and nitrogen compounds. The process experiment of electrochemical oxidation was conducted by using the stainless steel tube type reactor and the $Ti/IrO_2$ as anode. Free chlorine production and current efficiency variation for total nitrogen removal was compared depending on whether electrolyte is added, and the nitrogen type distribution under an operating condition. When chloride was added as electrolyte, it was found that production of free chlorine increased and the concentration of the chloride decreased as retention time passed. The concentration of chloride in influent decreased from 1,660 to 1,198 mg/L at the current density of $6.7A/dm^2$, while concentration of free chlorine increased to 132 mg/L. Current efficiency in removal of ammonium nitrogen was increased when chloride was dosed as electrolyte. It was observed that ammonium nitrogen was oxidized to nitrite and nitrate through electrochemical oxidation and that the concentration of total nitrogen in influent was reduced from 22.58 to 4.00 mg/L at the short retention time of 168 seconds through the electrochemical oxidation of nitrogen.

A Study on Ion Concentration Change of Acid Rain by the Succeeding Raintall (연속강우시 산성우의 이온농도 변화에 관한 조사연구)

  • 박경렬;김대선
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.11-20
    • /
    • 1990
  • To investigate ionic characteristics of acid rain by the succeeding rainfall. bulk precipitation was collected every each 5mm rainfall from march to october 1990 at Dae Jeon area. pH, sulfate nitrate, chloride, ammonium ion was measured and analyzed. The result was as follows: 1. The weighted average pH of rain was 5.1$\pm$ 0.72(4.15~7.6) and rain pH less than 5.5 was appeared 51.3% 2. Average ion concentrations of sulfate, nitrate, chloride and ammonium ion was 125.12 $\mu$eq/l, 62.38 $\mu$eq/l, 31.95 $\mu$eq/l, 66.6 $\mu$eq/l and rates of each anions was 57%, 28.4%, 14.6% and rate of sulfate by nitrate was 2 times. 3. There is no correlations time interval of rainfall and Ion concentration change. 4. From initial to 15mm rainfall, each ion concentrations were decreased. and average concentration of pH, SO$^{-2}_{4}$, Cl ion concentration was increased in the succeeding rainfall 5. Only sulfate ion was correlated by the simple regression analysis with pH except NO$^{-}_{3}$, Cl$^{-}$ and NH$_{4}^{+}$ Cl$^{-}$ correlation coefficient was very high at the multiple regression analysis with pH. 6. Simple & multiple correlation coefficient among anions and NH$^{+}_{4}$ was very high especially N$^{+}_{4}$ and SO$^{2-}_{4}$ at simple regression analysis and SO$^{-2}_{4}$ and NO$_{3}^{-}$, Cl$^{-}$, NH$_{4}^{-}$ at multiple regression analysis.

  • PDF

A study on effects of water-cement ratio and crack width on chloride ion transmission rate in concrete

  • Li, Yue;Chen, Xiaohan;Zhang, Guosheng
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.387-394
    • /
    • 2017
  • To study the effects of water-cement ratio changes and cracks on chloride ion transmission rate in cracked concrete, RCM method was adopted to accelerate the diffusion of chloride ion in cracked concrete, and the changes in chloride ion concentration and around the cracks are inferred by finite-element method. The test results show that as far as prefabricated cracks on concrete components are concerned, the width thresholds of two cracks on the concrete specimens with a water-cement ratio of 0.5 and 0.6 are 0.05 mm and 0.1 mm respectively, the width threshold of two cracks on the concrete specimens with a water-cement ratio of 0.4 is 0.05 mm and 0.2 mm respectively; and the results of numerical simulation show that the smaller the water-cement ratio is, the more significant effects of cracks on chloride ion transmission rate are. As a result, more attention shall be paid to the crack prevention, repairing and strengthening for high-strength concrete.

A survey on the fluctuation of dissolved solids into the groundwater in Chejudo (제주도 지하수의 증분변화에 대한 고제)

  • 금성홍;신승종;오상실;송가기;오순미
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.1
    • /
    • pp.67-80
    • /
    • 1993
  • This survey was carried out to take the status of seawater intrusion into groundwater wells located in the eastern area of Chejudo, to get the elementary data which may evaluate the level of would-be groundwater contamination, and to perform effective the effort that will supply the clear water for the residents. The sampling sites were northeastern districts of Haengwon, Handong, and Sangdo, southeastern districts of Susan, Nansan, and Samdal, and northwestern districts, as reference, of Aewol, Keumnung, Panpo, Kosan, Shindo, and Bosung. We collected the samples from the public tap water by month, and analysed electrical conductivity, sodium(Na), potassium(K), magnesium(Mg), calcium(Ca), bicarbonate($HC0_{3^-}$), and items of the criteria as drinking water. In the northeastern districts we also added the sampling sites to survey the fluctuations of dissolved solids according to distance from seashore, including two private boreholes and one public tap water of Dukchun. The result is as follows 1) In the northeastern district, the concentration of chloride ion showed large fluctations from 40mg/l to 100mg/l, but suitable for the criteria of drinking water. It was thought that the drought influenced. 2) In the Sangdo of the northeastern districts, similar tendancy to Hangwon and Handong was showed only in the concentration of chloride ion, but different tendancy was showed in chloride-bicarbonate ratio, calcium-magnesium ratio, and sodium adsorption ratio(SAR). Considering these facts, it was not thought that seawater intruded. 3) The components of Na and Cl showed rapid slope in the northeastern districts above 3km from seashore. 4) In the northwestern districts as reference, the concentration of chloride ion fluctuated slightly according to the sampling sites and dates, and the concentration of nitrate-nitrogen in some sites exceeded the criteria of drinking water. These were thought that the surface contaminants rather than the intrusion of seawater influenced mainly the groundwater, considering the correlation(r=0.732) of chloride ion and nitrate-nitrogen. 5) Then we must consider the regional characteristies of soil profile in order to prevent the contamination of groundwater, and moniter also the movement of main components within the sol1 profile, not only the research of the intrusion of seawater.

  • PDF

Analytical Study on the Chloride Ion's Permeation of Reinforced Concrete Repaired by Patching Repair Material (단면수복재로 보수시공한 철근콘크리트내로의 염화물이온 침투에관한 해석적 연구)

  • Yun, Sun-Young;Shin, Sang-Heon;Ryu, Byung-Cheol;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.617-620
    • /
    • 2008
  • When the RC structure repaired by patching repair method, which method refilles with patching repair material after removes degraded area, It is necessary to determine chloride ion's permeation from outside of the RC structure repaired by patching repair material. Therefore, in this study, damage from sea environment of structure was predicted, moreover, diffusion coefficient of concrete also determined to figure out rebar's corrosion and concentration of chloride ion. RCPT(Rapid Chloride Permeability Test) was used for ditermination of patching repair material's diffusion coefficient, also connection between material thickness and effect of chloride ion's permeation was examined in analytically. Results which derived by experimental test was used in FEM(Finite Element Method) and equation suggested by JSCE to predict concentration of chloride ion in different distance from surface.

  • PDF

Phosphorus Adsorption by Layered Double Hydroxide (층상이중수산화물을 이용한 인 흡착)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.404-410
    • /
    • 2005
  • A series of batch type adsorption experiments were performed to remove aquatic phosphorus, where the layered double hydroxide (HTAL-CI) was used as an powdered adsorbent. It showed high adsorption capacity (T-P removal: 99.9%) in the range of pH 5.5 to 8.8 in spite of providing low adsorption characteristics (pH<4). The adsorption isotherm was approximated as a modified Langmuir type equation, where the maximum adsorption amount (50.5mg-P/g) was obtained at around 80mg-P/L of phosphorus concentration. A phosphate ion can occupy three adsorption sites with a chloride ion considering the result that 1 mol of phosphate ion adsorbed corresponded to the 3 moles of chloride ion released. Although the chloride ion at less than 1,000mg-CI/L did not significantly affect the adsorption capacity of phosphate, carbonate ion inhibited the adsorption property.

A Study on the Initiation of Pitting Corrosion of Fe-17Cr Alloy Using Micro-Droplet Cell Technique (Micro-droplet cell을 이용한 Fe-17Cr 합금의 공식 발생에 대한 연구)

  • Kim, Jae-Jung;Lee, Jae-Bong
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.12
    • /
    • pp.809-816
    • /
    • 2008
  • The influences of various parameters such as inclusions, surface roughness, exposed areas and chloride ion concentrations on the initiation of pitting of Fe-17Cr alloy were investigated, using micro-droplet cell technique. Micro-droplet cell allows one to align the micro-electrode to the desired spot of the working electrode and measure directly local currents with the potentiodynamic polarization. Micro electrochemical tests were carried out at the inclusions after EDX analysis of inclusion. EDX analysis identified inclusions as Cr-oxides. It was found that some active inclusions among Cr-oxide inclusions acted as initiation sites for pitting corrosion. In addition, the rougher surface and the denser chloride ion concentration offered easier pit initiation sites, causing the more susceptible to pitting corrosion.

A Comparative Study of Sulfate and Chloride Intrusion in Mortar Sections: An Approach Using Laser Induced Breakdown Spectroscopy and Ion Exchange Membrane (LIBS와 이온교환막을 활용한 모르타르 단면 침투 황산염과 염화물 분석)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.221-229
    • /
    • 2023
  • This research aimed to conduct an empirical assessment of the penetration of chloride and sulfate ions into mortar sections using an anion exchange membrane(AEM) and laser-induced breakdown spectroscopy(LIBS). The study involved a simultaneous ion chromatography(IC) analysis and LIBS analysis performed on mortars immersed in varying concentrations of chloride and sulfate. The findings revealed that at the wavelengths specific to Chloride(837.59nm) and Sulfur(921.30nm), the LIBS intensity achieved using AEM surpassed that obtained with a paper substrate at equivalent penetration concentrations. A robust correlation was confirmed between LIBS intensity and chloride ion concentration. Furthermore, when juxtaposed with IC analysis concentration outcomes at identical depths, the AEM displayed a higher intensity. The research noted an enhancement in LIBS intensity and a diminution in errors within the low-concentration section when deploying AEM. However, for the Sulfur wavelength of 921.3nm, there remains a need to augment the sensitivity of the LIBS signal within the low-concentration section in future studies. The findings underscore the potential of employing AEM and LIBS for precise analysis of chloride and sulfate ion penetration into mortar sections. This strategy can aid in bolstering assessment precision and mitigating errors, particularly in regions with low concentrations. It is recommended to further research and develop methods to amplify the sensitivity of the LIBS signal for sulfur detection in low-concentration sections. In sum, the study accentuates the significance of employing advanced techniques like AEM and LIBS for efficacious and precise analysis in the domain of mortar section assessment.