• 제목/요약/키워드: chloride corrosion

검색결과 745건 처리시간 0.021초

열수송관에 연결된 에어벤트에 적용 가능한 부식 방지 방안 (Corrosion Protective Method Applicable to Air Vent Connected with a Heat Transport Pipe)

  • 송민지;최가현;김우철;이수열
    • Corrosion Science and Technology
    • /
    • 제22권2호
    • /
    • pp.115-122
    • /
    • 2023
  • This study aimed to elucidate causes of corrosion of heat transport pipes and air vents installed under a manhole of heat transport facilities and suggest effective anticorrosive measures by applying paints or adhesive tapes. It was found that air vent corrosion was attributed to corrosion under insulation caused by the inflow of water and the enrichment of chloride ions. The infiltrated water caused a hydrolysis of polyurethane foam (PUF) insulation by concentrating chloride ions at the interface between a pipe and the PUF. As insulator deteriorated, more chloride ions were eluted as confirmed by ion chromatograph (IC) analysis. As an effective method to prevent air vent corrosion, different types of paints and adhesive tapes with higher corrosion resistance on chloride ions were applied and environmental resistance tests were performed with those samples. Based on environmental test results of samples exposed to 10% HCl solution, it was revealed that a wax tape was the most adequate from a viewpoint of stability at operating condition, environmental resistance, surface treatment, and field applicability.

선형분극법을 이용한 보통프틀랜드시멘트 콘크리트의 임계염화물량 (Determination of Critical Chloride Content of Ordinary Portland Cement Concrete by Linear Polarization Technique)

  • 김홍삼;정해문;안태송
    • 한국세라믹학회지
    • /
    • 제44권9호
    • /
    • pp.524-528
    • /
    • 2007
  • The results of evaluating steel corrosion in concrete containing chloride content of various levels indicated that the more chloride content in concrete leads to the lower potential and higher corrosion current density. However, the open circuit potential of steel varied with time and exposure condition, and the corelation between the open circuit potential and corrosion current density was not obvious. In order to determine the critical threshold content of chloride of steel corrosion in concrete, the concept of average corrosion current density was employed. The range of critical chloride content in portland cement concretes was about $1.56{\sim}1.77%$($Cl^-$, %, wt of cement content) along with water-cement ratio, and higher water-cement ratio resulted in reduction in critical threshold chloride content.

염화물이 철근콘크리트의 부식에 미치는 영향 (The Effect of Chloride on the Corrosion of Reinforced Concrete)

  • 김정섭;신용석;이설;김광석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.147-154
    • /
    • 2005
  • 부식면적에 기준으로 살펴보면, 염화물이온 함유량이 증가할수록, 재령이 증가할수록 부식면적이 증가하는 것으로 나타났다. 특히 염화물이온 함유량이 $3kg/m^3$에서 $7kg/m^3$로 증가할때, 재령일이 730일에서 1035일로 증가할때 부식면적 증가 기울기가 큰 것으로 나타났다. 방청 시험체에 비해 무방청 시험체에서 약 8~35배정도 많은 부식면적을 나타내어 방청제 도포에 의한 부식방지에 효과를 확인할 수 있었다. 염화물이온을 함유하지 않은 경우 피복두께 증가에 따른 철근의 부식제어효과를 나타내었으나 염화물 이온을 함유한 시험체에서는 염화물 역확산, 시험오차 등의 복합적인 문제로 피복두께와 부식의 일정한 경향을 볼 수 없었다.

염화칼슘이 함유된 제설제로 인한 콘크리트 바닥판 단부의 염해에 관한 사례 연구 (A Case Study on Chloride Corrosion for the End Zone of Concrete Deck Subjected to De-icing Salts Added Calcium Chloride)

  • 정지승;김보헌;김일순
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.87-93
    • /
    • 2014
  • In this study, the reinforced concrete rahmen bridge damaged by the chloride attack was investigated. According to the investigation, the degraded concretes on cantilever kerb and end part were intensively observed. Thus, the chloride content test and half-cell method were performed to evaluate the degraded parts. As a result, the contents of chloride on degraded parts were C and D grade. On the other hand, the half-cell potential values of rebar in degraded concrete were measured with the minor corrosion. This rebar corrosion is expected to progressing. Chloride content D grade is due to expansion pressure by corrosion of rebar and freeze-thaw by permeate water, could see progresses rapidly degradation. In order to prevent chloride attack to concrete deck caused by deicing salts, corresponding to the chloride critical concentration must maintain grade b or at least grade c. Chloride condition evaluation standard apply to evaluation of marine structure chloride attack with chloride attack by deicing salts.

1년 동안 서울지역 토양에 매설된 스테인리스강의 부식 (Corrosion of Stainless Steel Pipes Buried in the Soils of Seoul Metropolitan During One Year)

  • 현영민;김희산;김영호;장현정;박영복;최영준
    • Corrosion Science and Technology
    • /
    • 제11권2호
    • /
    • pp.56-64
    • /
    • 2012
  • Factors affecting corrosion of stainless steels such as pH, oxidation and redox potential (ORP), soil resistivity, water content of soil, chloride ion concentration, bacteria activity, and corrosion potential have been investigated using soil analysis, bacterial analysis, surfacial analysis, and analysis of corrosion potentials of several stainless steels buried in 8 sites of Seoul metropolitan for one year. Corrosion potential was affected by occurrance of corrosion as well as bacteria activity but the behavior of corrosion potential with time is different depending on occurrance of corrosion and bacteria activity. The main factor affecting corrosion of stainless steels in soil is level of chloride ion concentration which is also a main factor affecting corrosion of stainless steels in chloride containing drinkable water. Furthermore, guideline of stainless steels in drinkable water is concluded to be applicable to that in soil by the results from surfacial analysis.

Control of Galvanic Corrosion Between A516Gr.55 Steel and AA7075T6 Depending on NaCl Concentration and Solution Temperature

  • Hur, S.Y.;Jeon, J.M.;Kim, K.T.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제19권6호
    • /
    • pp.281-287
    • /
    • 2020
  • Chloride ion is one of the most important corrosive agents in atmospheric corrosion, especially in marine environments. It has high adsorption rate and increases the conductivity of electrolytes. Since chloride ions affect the protective properties and the surface composition of the corrosion product, they increase the corrosion rate. A low level of chloride ions leads to uniform corrosion, whereas a high level of chloride ions may induce localized corrosion. However, higher solution temperatures tend to increase the corrosion rate by enhancing the migration of oxygen in the solution. This work focused on the effect of NaCl concentration and temperature on galvanic corrosion between A516Gr.55 carbon steel and AA7075T6 aluminum alloys. When AA7075T6 aluminum alloy was galvanically coupled to A516Gr.55 carbon steel, AA7075T6 was severely corroded regardless of NaCl concentration and solution temperature, unlike the corrosion properties of single specimen. The combined effect of surface treatment involving carbon steel and aluminum alloy on corrosion behavior was also discussed.

EIS를 이용한 염화물 및 방청제가 첨가된 콘크리트에 매립된 철근의 방식성능 평가에 관한 실험적 연구 (A Experimental Study on the Evaluation of Anti-corrosion Performance of rebar in concrete added chloride and inhibitor using EIS method)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2016
  • To evaluate anti-corrosion performance of rebar in concrete according to the amount of chloride and inhibitor, electrochemical impedance spectroscopy(EIS) method was conducted in this study. For the anti-corrosion performance evaluation according to time, Impedance of rebar in concrete was measured before and after 5 cycle of corrosion acceleration. As a results, The impedance of rebar in concrete added chloride decreased than before corrosion acceleration. However impedance of other specimens was maintained or increased than before corrosion acceleration.

  • PDF

On the Implementation of Fuzzy Arithmetic for Prediction Model Equation of Corrosion Initiation

  • Do Jeong-Yun;Song Hun;Soh Yang-Seob
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.1045-1051
    • /
    • 2005
  • For critical structures and application, where a given reliability must be met, it is necessary to account for uncertainties and variability in material properties, structural parameters affecting the corrosion process, in addition to the statistical and decision uncertainties. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. The parameters of the models are regarded as fuzzy numbers with proper membership function adapted to statistical data of the governing parameters and the fuzziness of the corrosion time is determined by the fuzzy arithmetic of interval arithmetic and extension principle

염화물에 노출된 콘크리트 기공 내에 솔방울 추출물의 부식 방청 특성 (Corrosion Inhibition Properties of Conifer Cone (Pinus resinosa) Extract in Chloride Contaminated Concrete Pore Solutions)

  • 카식 수비아;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.63-64
    • /
    • 2021
  • The corrosion inhibition properties of conifer cone (Pinus resinosa) extract were studied in synthetic concrete pore solutions (SCPS) with and without chloride environments by electrochemical methods. The electrochemical impedance spectroscopy (EIS) revealed that the conifer cone (CC) extract showed promising inhibition behavior by diminishing the corrosion rate of steel rebar both solutions i.e. with and without chloride. The extract of conifer cone hinders the corrosion reaction between steel rebar and aggressive ions. Further, it can be verified that the up to 1000mg.L-1 of CC extract can able to reduce the corrosion rate of steel rebar in chloride contaminated concrete.

  • PDF

염화물을 함유한 콘크리트 중의 철근방식을 위한 방청제의 효과 (Effect of Corrosion Inhibitor for Reinforcing Steel in Concrete Containing Chlorides)

  • 문한영;김성수
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.325-333
    • /
    • 1998
  • 염화물에 의한 콘크리트 중의 철근부식을 억제하기 위하여 콘크리트 배합시 방청제를 사용하는 방안이 일반적으로 많이 사용되고 있으나. 국내에서는 아직까지 방청제의 방식효과에 대한 연구는 찾아보기 어려운 실정이다. 본 연구에서는 염화물의 영향을 받는 콘크리트 중의 철근부식 억제를 위한 방안으로 방청제를 사용하여 철근의 방청효과를 알아보기 위하여 3종류의 방청제와 각각 사용량을 변화시킨 시험체를 제작하여 부식촉진 실험을 실시하였으며, 철근의 자연전위와 부시면적율을 측정하여 방식효과에 대하여 평가하였다. 그 결과 염화물의 혼입량이 지나치게 많을 경우에는 방청제의 양을 증가시켜도 방청효과가 크게 향상되지 않았으나. 염화물의 혼입량을 동일하게 사용하고 방청제의 양을 증가시켜도 방청효과가 크게 향상되지 않았으나, 염화물의 혼입량을 동일하게 방청제의 양을 증가시킬 경우에는 방청효과가 현저하게 좋아짐을 알 수 있었다.