흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험 (The Experiment of Grid Characteristics for High-voltage Radiography of Chest)

  • 김정민;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권2호
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

진폐 정밀/요양기관과 요양기관의 흉부 방사선분야 정도관리 비교 (Comparison of Quality Control for Chest Radiography between Special Examination and Medical Institution for Pneumoconiosis)

  • 이원정
    • 한국콘텐츠학회논문지
    • /
    • 제11권2호
    • /
    • pp.322-330
    • /
    • 2011
  • 전국 33개 진폐요양기관 흉부 방사선분야 정도관리 실태조사를 실시하여 정밀/요양기관(17개)과 요양기관(16개)에 대해 산업안전보건연구원 진폐정도관리 평가표를 이용하여 촬영기술, 판독환경 및 화질평가 결과를 비교 분석하였다. 촬영기술과 판독환경은 연구자가 직접방문하여 평가하였고, 화질평가는 각 진폐 요양기관에서 보내온 영상을 기관마다 10장씩 무작위추출하여 2명의 흉부 영상의학과 전문의가 영상에 대한 어떤 정보도 모르는 상태에서 개별적으로 실시하였다. 정밀/요양기관과 요양기관 사이, 흉부 방사선 촬영 장치의 성능, 사용기간, 촬영방법에서는 유의한 차이가 없었지만, 단순 흉부 촬영조건에서 관전압과 그리드 비에서 유의한 차이가 있었다. 또한, 촬영기술과 판독환경평가에서는 정밀/요양기관이 요양기관 보다 유의하게 높았고, 화질평가에서도 높았지만 유의한 차이는 없었다. 따라서, 진폐합병증이 있는 요양환자의 신뢰성있고 정확한 진단을 위해서는 요양기관의 흉부 방사선분야 정도관리 향상을 위한 외부평가 및 교육이 필요하다.

영상의학과 흉부 엑스선 촬영 기기의 세균 오염도 (Bacteriological Research for the Contamination of Equipment in Chest Radiography)

  • 최승구;송운흥;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.395-401
    • /
    • 2015
  • 영상의학과의 흉부엑스선 검사에서 감염관리에 대한 기기의 오염 정도를 세균학적으로 확인하고 균을 동정하여 병원감염의 예방과 감염관리방안을 마련하는데 목적이 있다. 영상의학과 흉부 엑스선 검사에서 환자의 기기 접촉부위인 어깨, 손, 턱, 흉부 측면촬영의 손잡이 부위를 70% 이소프로필 알코올로 소독하기 전과 후를 면봉으로 검체를 채취하여 세균을 동정하여 비교하여 분석하였다. 흉부 엑스선 기기에서 소독전의 측면촬영의 손잡이에서 그람 양성의 Staphylococcus가 분리되었다. 최종동정을 위해 노보바이오신 (nobobiocin) 항생제 시험을 실시하여 민감성으로 Staphylococcus epidermidis로 확정하였다. 흉부촬영 기기에서 측면촬영의 손잡이 부위를 소독 전에 Staphylococcus epidermidis 균이 검출되었다. 흉부엑스선 검사에서 기기를 주기적인 소독 및 멸균을 실시하여 병원감염을 예방하는 관리방안을 마련하여야 한다.

Filter effect를 이용(利用)한 Chest Radiography (A Study on Filter Effect on Improvement of Chest Radiography)

  • 임태낭;석전유치
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.23-33
    • /
    • 1984
  • In the present study, we determined reduction value of radiation on chest film by film method and made a reduction curves. The reduction radio in exposure to radiation was induced by comparative investigation of characteristic curves and reduction one. Basing on these result, we could reduce a radiation dose on body surface in 50% at the time of chest radiography, if 17.8mm aluminium or 0.87mm copper filter were used in addition to conventional filter at 140KV tube voltage. The present study further revealed that the additional use of the aluminium or copper filter at the time of high voltage radiography in chest facilitates to identify an image of some pathologic focus overlapping wist clavicle and ribs.

  • PDF

동시(同時) 이선질(二線質)에 의한 Chest Radiography의 연구(硏究) (A Study on the Chest Radiography by Simultaneous Double Radiation Quality)

  • 임태랑;석전유치;진등굉일;전전미향
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제12권1호
    • /
    • pp.17-23
    • /
    • 1989
  • We have developed of the exposure technique for the chest radiography to get different contrast in left and right lung fields simultaneously for the effective diagnosis, I.E., get high contrast to detect tuberculosis, dispersal shadow or exudative lesions of early tuberculosis and get better sharpness and wider latitude to detect growing lesions of lung cancer or lesions overlapped with bones. As a result, by using an additional filter Cu 1.2mm with BX-III screen side and sheet of yellow cellophane on BF-III screen side at the conventional KV ($80KV{\sim}100KV$) for the chest X-ray, we can get similar densities in both left and right lung fields and, thus, this method is considered to be very effective for the quality diagnosis for the routine chest radiography.

  • PDF

Fuji Computed Radiography(FCR)를 이용한 흥부 X선사진의 평가 (Evaluation of the Chest Radiography using Fuji Computed Radiography(FCR) System)

  • 김영성;황남선;여영복;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권2호
    • /
    • pp.9-14
    • /
    • 1991
  • Chest radiograms obtained by using Fuji Computed Radiography(FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic informations than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

  • PDF

Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향 (The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography)

  • 권순무;박창희;박정규;송운흥;정재은
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.203-210
    • /
    • 2014
  • X선을 이용한 chest radiography는 일반적으로 180 cm의 SID에서 실시되고 있다. digital chest radiography에서 AEC를 적용하고 120 kVp, 320 mA에서 SID를 180 cm부터 340 cm까지 20 cm 단위로 증가시켜 가며 영상의 질과 환자선량의 관계를 알아보았다. chest phantom 영상의 정성적인 영상평가를 위해 VGA를, 정량적인 평가를 위해 SNR을 분석하였다. 선량은 ESAK로 측정하고 effective dose는 PCXMC를 이용하였다. 연구결과 일반적으로 시행되는 SID 180 cm를 기준으로 했을 때, ESAK의 경우 240 cm, 280 cm, 320 cm에서 각각 8.7%, 11.47%, 13.56%의 유의한 감소가 있었다. effective dose의 경우 전신에 대해 2.89%, 4.67%, 6.41%의 감소, 폐에서 5.08%, 6.98%, 9.6%의 감소가 관찰되었다. SNR의 경우 각각 9.04%, 8.24%, 11.46%의 감소가 관찰되었으며 특히, SID 260 cm ~ 300 cm 구간에서 8.03%의 작은 감소가 나타났고 SID 340 cm까지도 5.24로 5이하로 감소되지 않았다. VGA에서는 통계적으로 유의한 차이가 없는 진단적 가치가 높은 영상으로 평가되었다. 따라서 eigital chest radiography에서 SID를 300 cm까지 증가시킴으로 화질의 저하 없이 환자선량을 감소시킬 수 있을 것으로 기대된다.

진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교 (A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography)

  • 이원정;고경선;박재성;김성진;추상덕;박소영;최병순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.85-91
    • /
    • 2010
  • 분진에 노출되었던 자가 진폐소견을 갖고 있으면서 합병증이 발생하면 진폐요양기관에서 입원 치료를 받을 수 있다. 본 연구에서는 전국 33개 진폐요양기관의 실태조사 결과로부터 흉부 디지털촬영기관과 아날로그촬영 기관의 정도관리를 비교 분석 하였다. 전체 진폐요양기관 중 24개 기관은 디지털촬영을 실시하고 있었고, 9개 기관은 아날로그촬영을 실시하고 있었다. 산업안전보건연구원 특수건강진단(진폐정도관리)기관 흉부 방사선분야 평가표를 이용하여 디지털촬영 기관과 아날로그촬영기관 사이에 촬영기술 및 화질, 판독환경평가 결과를 비교하였고, 화질은 진폐판독정도관리 교육을 수료하고 진폐 판독경험이 많은 2명의 흉부 영상의학과전문의가 각각 독립적으로 평가한 후, 평균값을 사용하여 비교 하였다. 디지털촬영기관과 아날로그촬영기관 사이에 촬영장치 및 관전류, 조사시간에서는 유의한 차이를 보이지 않았지만, 관전압, 격자비에서는 유의한 차이를 보였다. 디지털촬영기관이 아날로그촬영기관보다 촬영기술과 판독환경에서 통계학적으로 유의하게 높았고, 화질에서도 높았지만 유의하지는 않았다. 따라서, 진폐요양기관이 아날로그촬영에서 디지털촬영으로 전환하게 되면 정도관리의 향상을 가져올 수 있다.

비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징 (Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 정회원;김정민;정만희;임은경
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

portable 흉부촬영시 공간산란선량에 관한 연구 (A Study on the Scattered Dose in Portable Chest Radiography)

  • 안봉선;이환형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF